A 3D model analysis of knee prosthetic motion (2nd report, variations of articulating pattern for prosthetic geometries and walking conditions)

Tadasuke Katsuhara, Takefumi Koda, Shunji Hirokawa, Ayaka Otsuki

Research output: Contribution to journalArticle

Abstract

The object of this study is to introduce contact points' trajectories on the articulating surfaces and kinematics of knee prosthesis under various walking conditions for various types of prosthesis to help to design new prosthesis. After creating a 3D mathematical model including the tibio-femoral and patello-femoral compartments of prosthesis, we performed simulation analyses using the model. In the simulation, we employed three typical types of prostheses; conformity, laxity and flat types, for normal and elderly gaits and an elderly gait with a misaligned prosthesis. The simulation results demonstrated that trajectories and pressure of contact points on the articulating surfaces were much influenced by the prosthetic types and their alignments. The results also demonstrated that in some cases elderly gait exhibits unbalance of joint contact forces between the medio and lateral sides, excessive posterior deviation of contact points on the tibial surface. This warns against the current notion that the prosthesis may be more endurable for elderly gait for its less activity than normal gait.

Original languageEnglish
Pages (from-to)161-167
Number of pages7
JournalNihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
Volume72
Issue number1
Publication statusPublished - Jan 1 2006

Fingerprint

Prosthetics
Point contacts
Geometry
Trajectories
Knee prostheses
Kinematics
Prostheses and Implants
Mathematical models

All Science Journal Classification (ASJC) codes

  • Mechanics of Materials
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering

Cite this

A 3D model analysis of knee prosthetic motion (2nd report, variations of articulating pattern for prosthetic geometries and walking conditions). / Katsuhara, Tadasuke; Koda, Takefumi; Hirokawa, Shunji; Otsuki, Ayaka.

In: Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, Vol. 72, No. 1, 01.01.2006, p. 161-167.

Research output: Contribution to journalArticle

@article{684948c6c8d442338630993783306650,
title = "A 3D model analysis of knee prosthetic motion (2nd report, variations of articulating pattern for prosthetic geometries and walking conditions)",
abstract = "The object of this study is to introduce contact points' trajectories on the articulating surfaces and kinematics of knee prosthesis under various walking conditions for various types of prosthesis to help to design new prosthesis. After creating a 3D mathematical model including the tibio-femoral and patello-femoral compartments of prosthesis, we performed simulation analyses using the model. In the simulation, we employed three typical types of prostheses; conformity, laxity and flat types, for normal and elderly gaits and an elderly gait with a misaligned prosthesis. The simulation results demonstrated that trajectories and pressure of contact points on the articulating surfaces were much influenced by the prosthetic types and their alignments. The results also demonstrated that in some cases elderly gait exhibits unbalance of joint contact forces between the medio and lateral sides, excessive posterior deviation of contact points on the tibial surface. This warns against the current notion that the prosthesis may be more endurable for elderly gait for its less activity than normal gait.",
author = "Tadasuke Katsuhara and Takefumi Koda and Shunji Hirokawa and Ayaka Otsuki",
year = "2006",
month = "1",
day = "1",
language = "English",
volume = "72",
pages = "161--167",
journal = "Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C",
issn = "0387-5024",
publisher = "The Japan Society of Mechanical Engineers",
number = "1",

}

TY - JOUR

T1 - A 3D model analysis of knee prosthetic motion (2nd report, variations of articulating pattern for prosthetic geometries and walking conditions)

AU - Katsuhara, Tadasuke

AU - Koda, Takefumi

AU - Hirokawa, Shunji

AU - Otsuki, Ayaka

PY - 2006/1/1

Y1 - 2006/1/1

N2 - The object of this study is to introduce contact points' trajectories on the articulating surfaces and kinematics of knee prosthesis under various walking conditions for various types of prosthesis to help to design new prosthesis. After creating a 3D mathematical model including the tibio-femoral and patello-femoral compartments of prosthesis, we performed simulation analyses using the model. In the simulation, we employed three typical types of prostheses; conformity, laxity and flat types, for normal and elderly gaits and an elderly gait with a misaligned prosthesis. The simulation results demonstrated that trajectories and pressure of contact points on the articulating surfaces were much influenced by the prosthetic types and their alignments. The results also demonstrated that in some cases elderly gait exhibits unbalance of joint contact forces between the medio and lateral sides, excessive posterior deviation of contact points on the tibial surface. This warns against the current notion that the prosthesis may be more endurable for elderly gait for its less activity than normal gait.

AB - The object of this study is to introduce contact points' trajectories on the articulating surfaces and kinematics of knee prosthesis under various walking conditions for various types of prosthesis to help to design new prosthesis. After creating a 3D mathematical model including the tibio-femoral and patello-femoral compartments of prosthesis, we performed simulation analyses using the model. In the simulation, we employed three typical types of prostheses; conformity, laxity and flat types, for normal and elderly gaits and an elderly gait with a misaligned prosthesis. The simulation results demonstrated that trajectories and pressure of contact points on the articulating surfaces were much influenced by the prosthetic types and their alignments. The results also demonstrated that in some cases elderly gait exhibits unbalance of joint contact forces between the medio and lateral sides, excessive posterior deviation of contact points on the tibial surface. This warns against the current notion that the prosthesis may be more endurable for elderly gait for its less activity than normal gait.

UR - http://www.scopus.com/inward/record.url?scp=33645138275&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33645138275&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:33645138275

VL - 72

SP - 161

EP - 167

JO - Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

JF - Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

SN - 0387-5024

IS - 1

ER -