A calibration of setting of mach probes by observing GAM oscillations

Kimitaka Itoh, Kaijun Zhao, Jiaqi Dong, Sanae I. Itoh, Akihide Fujisawa, Shigeru Inagaki, Makoto Sasaki, Yoshihiko Nagashima, Yusuke Kosuga, Jun Cheng, Tatsuya Kobayashi

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The influence of relative displacement of Mach probe (which is placed near the top of magnetic surface) on the interference of signals is discussed. An error can arise in measured value of poloidal electric field. The Mach number perturbation at the GAM frequency has an interference from the density perturbation. The interference from the density perturbation can propagate to all of Mach number measurement. By observing the signals associated with GAM oscillations, the error in setting the probe arrays can be detected. This result can be applied to correct the positioning of probes.

Original languageEnglish
Article number1402002
JournalPlasma and Fusion Research
Volume11
DOIs
Publication statusPublished - Jan 1 2016

Fingerprint

interference
Mach number
perturbation
oscillations
probes
positioning
electric fields

All Science Journal Classification (ASJC) codes

  • Condensed Matter Physics

Cite this

A calibration of setting of mach probes by observing GAM oscillations. / Itoh, Kimitaka; Zhao, Kaijun; Dong, Jiaqi; Itoh, Sanae I.; Fujisawa, Akihide; Inagaki, Shigeru; Sasaki, Makoto; Nagashima, Yoshihiko; Kosuga, Yusuke; Cheng, Jun; Kobayashi, Tatsuya.

In: Plasma and Fusion Research, Vol. 11, 1402002, 01.01.2016.

Research output: Contribution to journalArticle

@article{17184e0a82234be6a5d4240d54efc370,
title = "A calibration of setting of mach probes by observing GAM oscillations",
abstract = "The influence of relative displacement of Mach probe (which is placed near the top of magnetic surface) on the interference of signals is discussed. An error can arise in measured value of poloidal electric field. The Mach number perturbation at the GAM frequency has an interference from the density perturbation. The interference from the density perturbation can propagate to all of Mach number measurement. By observing the signals associated with GAM oscillations, the error in setting the probe arrays can be detected. This result can be applied to correct the positioning of probes.",
author = "Kimitaka Itoh and Kaijun Zhao and Jiaqi Dong and Itoh, {Sanae I.} and Akihide Fujisawa and Shigeru Inagaki and Makoto Sasaki and Yoshihiko Nagashima and Yusuke Kosuga and Jun Cheng and Tatsuya Kobayashi",
year = "2016",
month = "1",
day = "1",
doi = "10.1585/pfr.11.1402002",
language = "English",
volume = "11",
journal = "Plasma and Fusion Research",
issn = "1880-6821",
publisher = "The Japan Society of Plasma Science and Nuclear Fusion Research (JSPF)",

}

TY - JOUR

T1 - A calibration of setting of mach probes by observing GAM oscillations

AU - Itoh, Kimitaka

AU - Zhao, Kaijun

AU - Dong, Jiaqi

AU - Itoh, Sanae I.

AU - Fujisawa, Akihide

AU - Inagaki, Shigeru

AU - Sasaki, Makoto

AU - Nagashima, Yoshihiko

AU - Kosuga, Yusuke

AU - Cheng, Jun

AU - Kobayashi, Tatsuya

PY - 2016/1/1

Y1 - 2016/1/1

N2 - The influence of relative displacement of Mach probe (which is placed near the top of magnetic surface) on the interference of signals is discussed. An error can arise in measured value of poloidal electric field. The Mach number perturbation at the GAM frequency has an interference from the density perturbation. The interference from the density perturbation can propagate to all of Mach number measurement. By observing the signals associated with GAM oscillations, the error in setting the probe arrays can be detected. This result can be applied to correct the positioning of probes.

AB - The influence of relative displacement of Mach probe (which is placed near the top of magnetic surface) on the interference of signals is discussed. An error can arise in measured value of poloidal electric field. The Mach number perturbation at the GAM frequency has an interference from the density perturbation. The interference from the density perturbation can propagate to all of Mach number measurement. By observing the signals associated with GAM oscillations, the error in setting the probe arrays can be detected. This result can be applied to correct the positioning of probes.

UR - http://www.scopus.com/inward/record.url?scp=85034663693&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85034663693&partnerID=8YFLogxK

U2 - 10.1585/pfr.11.1402002

DO - 10.1585/pfr.11.1402002

M3 - Article

AN - SCOPUS:85034663693

VL - 11

JO - Plasma and Fusion Research

JF - Plasma and Fusion Research

SN - 1880-6821

M1 - 1402002