A cubic-anvil high-pressure device for pulsed neutron powder diffraction

J. Abe, M. Arakawa, T. Hattori, H. Arima, H. Kagi, K. Komatsu, A. Sano-Furukawa, Y. Uwatoko, K. Matsubayashi, S. Harjo, A. Moriai, T. Ito, K. Aizawa, M. Arai, W. Utsumi

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A compact cubic-anvil high-pressure device was developed for in situ neutron powder diffraction studies. In this device, a cubic shaped pressure medium is compressed by six anvils, and neutron beams pass through gaps between the anvils. The first high-pressure experiment using this device was conducted at J-PARC and clearly showed the neutron diffraction patterns of Pb. Combining the cubic-anvil high-pressure device with a pulsed neutron source will prove to be a useful tool for neutron diffraction experiments.

Original languageEnglish
Article number043910
JournalReview of Scientific Instruments
Volume81
Issue number4
DOIs
Publication statusPublished - Apr 1 2010
Externally publishedYes

Fingerprint

Neutron powder diffraction
anvils
neutrons
Neutron diffraction
diffraction
neutron diffraction
Neutron beams
Neutron sources
neutron beams
neutron sources
Diffraction patterns
diffraction patterns
Experiments

All Science Journal Classification (ASJC) codes

  • Instrumentation

Cite this

Abe, J., Arakawa, M., Hattori, T., Arima, H., Kagi, H., Komatsu, K., ... Utsumi, W. (2010). A cubic-anvil high-pressure device for pulsed neutron powder diffraction. Review of Scientific Instruments, 81(4), [043910]. https://doi.org/10.1063/1.3384238

A cubic-anvil high-pressure device for pulsed neutron powder diffraction. / Abe, J.; Arakawa, M.; Hattori, T.; Arima, H.; Kagi, H.; Komatsu, K.; Sano-Furukawa, A.; Uwatoko, Y.; Matsubayashi, K.; Harjo, S.; Moriai, A.; Ito, T.; Aizawa, K.; Arai, M.; Utsumi, W.

In: Review of Scientific Instruments, Vol. 81, No. 4, 043910, 01.04.2010.

Research output: Contribution to journalArticle

Abe, J, Arakawa, M, Hattori, T, Arima, H, Kagi, H, Komatsu, K, Sano-Furukawa, A, Uwatoko, Y, Matsubayashi, K, Harjo, S, Moriai, A, Ito, T, Aizawa, K, Arai, M & Utsumi, W 2010, 'A cubic-anvil high-pressure device for pulsed neutron powder diffraction', Review of Scientific Instruments, vol. 81, no. 4, 043910. https://doi.org/10.1063/1.3384238
Abe, J. ; Arakawa, M. ; Hattori, T. ; Arima, H. ; Kagi, H. ; Komatsu, K. ; Sano-Furukawa, A. ; Uwatoko, Y. ; Matsubayashi, K. ; Harjo, S. ; Moriai, A. ; Ito, T. ; Aizawa, K. ; Arai, M. ; Utsumi, W. / A cubic-anvil high-pressure device for pulsed neutron powder diffraction. In: Review of Scientific Instruments. 2010 ; Vol. 81, No. 4.
@article{499b1c288cad47a0b2c6bf617f18ceba,
title = "A cubic-anvil high-pressure device for pulsed neutron powder diffraction",
abstract = "A compact cubic-anvil high-pressure device was developed for in situ neutron powder diffraction studies. In this device, a cubic shaped pressure medium is compressed by six anvils, and neutron beams pass through gaps between the anvils. The first high-pressure experiment using this device was conducted at J-PARC and clearly showed the neutron diffraction patterns of Pb. Combining the cubic-anvil high-pressure device with a pulsed neutron source will prove to be a useful tool for neutron diffraction experiments.",
author = "J. Abe and M. Arakawa and T. Hattori and H. Arima and H. Kagi and K. Komatsu and A. Sano-Furukawa and Y. Uwatoko and K. Matsubayashi and S. Harjo and A. Moriai and T. Ito and K. Aizawa and M. Arai and W. Utsumi",
year = "2010",
month = "4",
day = "1",
doi = "10.1063/1.3384238",
language = "English",
volume = "81",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "4",

}

TY - JOUR

T1 - A cubic-anvil high-pressure device for pulsed neutron powder diffraction

AU - Abe, J.

AU - Arakawa, M.

AU - Hattori, T.

AU - Arima, H.

AU - Kagi, H.

AU - Komatsu, K.

AU - Sano-Furukawa, A.

AU - Uwatoko, Y.

AU - Matsubayashi, K.

AU - Harjo, S.

AU - Moriai, A.

AU - Ito, T.

AU - Aizawa, K.

AU - Arai, M.

AU - Utsumi, W.

PY - 2010/4/1

Y1 - 2010/4/1

N2 - A compact cubic-anvil high-pressure device was developed for in situ neutron powder diffraction studies. In this device, a cubic shaped pressure medium is compressed by six anvils, and neutron beams pass through gaps between the anvils. The first high-pressure experiment using this device was conducted at J-PARC and clearly showed the neutron diffraction patterns of Pb. Combining the cubic-anvil high-pressure device with a pulsed neutron source will prove to be a useful tool for neutron diffraction experiments.

AB - A compact cubic-anvil high-pressure device was developed for in situ neutron powder diffraction studies. In this device, a cubic shaped pressure medium is compressed by six anvils, and neutron beams pass through gaps between the anvils. The first high-pressure experiment using this device was conducted at J-PARC and clearly showed the neutron diffraction patterns of Pb. Combining the cubic-anvil high-pressure device with a pulsed neutron source will prove to be a useful tool for neutron diffraction experiments.

UR - http://www.scopus.com/inward/record.url?scp=77952336670&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77952336670&partnerID=8YFLogxK

U2 - 10.1063/1.3384238

DO - 10.1063/1.3384238

M3 - Article

C2 - 20441353

AN - SCOPUS:77952336670

VL - 81

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 4

M1 - 043910

ER -