Abstract

A removal procedure of a femoral cement mantle in hip revision arthroplasty has a risk of causing perforation or fracture, especially when removing a well-fixed distal cement plug. A high-powered drill equipped with a centralizer was developed to remove the distal cement plug safely. Using the drill equipped with a centralizer, the cement plug was removed well enough to insert a new component without causing perforation during the operation.

Original languageEnglish
Pages (from-to)231-233
Number of pages3
JournalJournal of Arthroplasty
Volume15
Issue number2
DOIs
Publication statusPublished - Jan 1 2000

Fingerprint

Device Removal
Mandrillus
Thigh
Arthroplasty
Hip

All Science Journal Classification (ASJC) codes

  • Orthopedics and Sports Medicine

Cite this

A device for removal of femoral distal cement plug during hip revision arthroplasty : A high-powered drill equipped with a centralizer. / Jingushi, S.; Noguchi, Y.; Shuto, T.; Nakashima, Yasuharu; Iwamoto, Y.

In: Journal of Arthroplasty, Vol. 15, No. 2, 01.01.2000, p. 231-233.

Research output: Contribution to journalArticle

@article{a2e2564995354308bc8f8691d427fce6,
title = "A device for removal of femoral distal cement plug during hip revision arthroplasty: A high-powered drill equipped with a centralizer",
abstract = "A removal procedure of a femoral cement mantle in hip revision arthroplasty has a risk of causing perforation or fracture, especially when removing a well-fixed distal cement plug. A high-powered drill equipped with a centralizer was developed to remove the distal cement plug safely. Using the drill equipped with a centralizer, the cement plug was removed well enough to insert a new component without causing perforation during the operation.",
author = "S. Jingushi and Y. Noguchi and T. Shuto and Yasuharu Nakashima and Y. Iwamoto",
year = "2000",
month = "1",
day = "1",
doi = "10.1016/S0883-5403(00)90374-7",
language = "English",
volume = "15",
pages = "231--233",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "2",

}

TY - JOUR

T1 - A device for removal of femoral distal cement plug during hip revision arthroplasty

T2 - A high-powered drill equipped with a centralizer

AU - Jingushi, S.

AU - Noguchi, Y.

AU - Shuto, T.

AU - Nakashima, Yasuharu

AU - Iwamoto, Y.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - A removal procedure of a femoral cement mantle in hip revision arthroplasty has a risk of causing perforation or fracture, especially when removing a well-fixed distal cement plug. A high-powered drill equipped with a centralizer was developed to remove the distal cement plug safely. Using the drill equipped with a centralizer, the cement plug was removed well enough to insert a new component without causing perforation during the operation.

AB - A removal procedure of a femoral cement mantle in hip revision arthroplasty has a risk of causing perforation or fracture, especially when removing a well-fixed distal cement plug. A high-powered drill equipped with a centralizer was developed to remove the distal cement plug safely. Using the drill equipped with a centralizer, the cement plug was removed well enough to insert a new component without causing perforation during the operation.

UR - http://www.scopus.com/inward/record.url?scp=0034089794&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034089794&partnerID=8YFLogxK

U2 - 10.1016/S0883-5403(00)90374-7

DO - 10.1016/S0883-5403(00)90374-7

M3 - Article

C2 - 10708092

AN - SCOPUS:0034089794

VL - 15

SP - 231

EP - 233

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

IS - 2

ER -