A Fault Diagnosis System for the Continuous Process with Load Fluctuations

Boh Yoh Shibata, Yoshifumi Tsuge, Hisayoshi Matsuyama, Eiji O’Shima

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A method for fault diagnosis of a continuous process with load fluctuations has been developed. It consists of two algorithms, one an efficient algorithm for data rectification developed by introducing Akaike’s Information Criterion and the other a fault diagnosis algorithm utilizing the signed directed graph. The former detects abnormal values of the state variables in the process with load fluctuations and supplies them to the latter. The latter searches candidates for the origin of failure which can explain all the abnormal values detected by the former. The efficency of this method is demonstrated by applying it to three types of miniature pipelines with different configurations.

Original languageEnglish
Pages (from-to)734-740
Number of pages7
Journalkagaku kogaku ronbunshu
Volume13
Issue number6
DOIs
Publication statusPublished - Jan 1 1987

Fingerprint

Failure analysis
Directed graphs
Pipelines

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

A Fault Diagnosis System for the Continuous Process with Load Fluctuations. / Shibata, Boh Yoh; Tsuge, Yoshifumi; Matsuyama, Hisayoshi; O’Shima, Eiji.

In: kagaku kogaku ronbunshu, Vol. 13, No. 6, 01.01.1987, p. 734-740.

Research output: Contribution to journalArticle

Shibata, Boh Yoh ; Tsuge, Yoshifumi ; Matsuyama, Hisayoshi ; O’Shima, Eiji. / A Fault Diagnosis System for the Continuous Process with Load Fluctuations. In: kagaku kogaku ronbunshu. 1987 ; Vol. 13, No. 6. pp. 734-740.
@article{9c954ab16d6645a2ab9abf1b8b429f48,
title = "A Fault Diagnosis System for the Continuous Process with Load Fluctuations",
abstract = "A method for fault diagnosis of a continuous process with load fluctuations has been developed. It consists of two algorithms, one an efficient algorithm for data rectification developed by introducing Akaike’s Information Criterion and the other a fault diagnosis algorithm utilizing the signed directed graph. The former detects abnormal values of the state variables in the process with load fluctuations and supplies them to the latter. The latter searches candidates for the origin of failure which can explain all the abnormal values detected by the former. The efficency of this method is demonstrated by applying it to three types of miniature pipelines with different configurations.",
author = "Shibata, {Boh Yoh} and Yoshifumi Tsuge and Hisayoshi Matsuyama and Eiji O’Shima",
year = "1987",
month = "1",
day = "1",
doi = "10.1252/kakoronbunshu.13.734",
language = "English",
volume = "13",
pages = "734--740",
journal = "Kagaku Kogaku Ronbunshu",
issn = "0386-216X",
publisher = "The Society of Chemical Engineers, Japan",
number = "6",

}

TY - JOUR

T1 - A Fault Diagnosis System for the Continuous Process with Load Fluctuations

AU - Shibata, Boh Yoh

AU - Tsuge, Yoshifumi

AU - Matsuyama, Hisayoshi

AU - O’Shima, Eiji

PY - 1987/1/1

Y1 - 1987/1/1

N2 - A method for fault diagnosis of a continuous process with load fluctuations has been developed. It consists of two algorithms, one an efficient algorithm for data rectification developed by introducing Akaike’s Information Criterion and the other a fault diagnosis algorithm utilizing the signed directed graph. The former detects abnormal values of the state variables in the process with load fluctuations and supplies them to the latter. The latter searches candidates for the origin of failure which can explain all the abnormal values detected by the former. The efficency of this method is demonstrated by applying it to three types of miniature pipelines with different configurations.

AB - A method for fault diagnosis of a continuous process with load fluctuations has been developed. It consists of two algorithms, one an efficient algorithm for data rectification developed by introducing Akaike’s Information Criterion and the other a fault diagnosis algorithm utilizing the signed directed graph. The former detects abnormal values of the state variables in the process with load fluctuations and supplies them to the latter. The latter searches candidates for the origin of failure which can explain all the abnormal values detected by the former. The efficency of this method is demonstrated by applying it to three types of miniature pipelines with different configurations.

UR - http://www.scopus.com/inward/record.url?scp=84945122349&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84945122349&partnerID=8YFLogxK

U2 - 10.1252/kakoronbunshu.13.734

DO - 10.1252/kakoronbunshu.13.734

M3 - Article

AN - SCOPUS:84945122349

VL - 13

SP - 734

EP - 740

JO - Kagaku Kogaku Ronbunshu

JF - Kagaku Kogaku Ronbunshu

SN - 0386-216X

IS - 6

ER -