A new relative proton polarimeter for RHIC

Hai Huang, I. Alekseev, G. Bunce, N. Bruner, A. Deshpande, Y. Goto, D. Fields, K. Imai, M. Ishihara, V. Kanavets, K. Kurita, Z. Li, B. Lozowski, W. MacKay, G. Mahler, Y. Makdisi, S. Rescia, T. Roser, N. Saito, H. Spinka & 6 others D. Svirida, Junji Tojo, D. Underwood, H. Wang, W. Zhang, L. Zhao

Research output: Contribution to conferencePaper

1 Citation (Scopus)

Abstract

An innovative polarimeter based on proton carbon elastic scattering in the Coulomb Nuclear Interference (CNI) region has been installed and commissioned in the Blue ring of RHIC during the first RHIC polarized proton commissioning in September, 2000. The polarimeter consists of ultra-thin carbon targets and four silicon detectors. All elements are in a 1.6 meter vacuum chamber. This paper summarizes the polarimeter design issues and recent commissioning results.

Original languageEnglish
Pages2443-2445
Number of pages3
Publication statusPublished - Dec 1 2001
Externally publishedYes
Event2001 Particle Accelerator Conference - Chicago, IL, United States
Duration: Jun 18 2001Jun 22 2001

Other

Other2001 Particle Accelerator Conference
CountryUnited States
CityChicago, IL
Period6/18/016/22/01

Fingerprint

Polarimeters
Protons
Silicon detectors
Carbon
Elastic scattering
Chemical elements
Vacuum

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Huang, H., Alekseev, I., Bunce, G., Bruner, N., Deshpande, A., Goto, Y., ... Zhao, L. (2001). A new relative proton polarimeter for RHIC. 2443-2445. Paper presented at 2001 Particle Accelerator Conference, Chicago, IL, United States.

A new relative proton polarimeter for RHIC. / Huang, Hai; Alekseev, I.; Bunce, G.; Bruner, N.; Deshpande, A.; Goto, Y.; Fields, D.; Imai, K.; Ishihara, M.; Kanavets, V.; Kurita, K.; Li, Z.; Lozowski, B.; MacKay, W.; Mahler, G.; Makdisi, Y.; Rescia, S.; Roser, T.; Saito, N.; Spinka, H.; Svirida, D.; Tojo, Junji; Underwood, D.; Wang, H.; Zhang, W.; Zhao, L.

2001. 2443-2445 Paper presented at 2001 Particle Accelerator Conference, Chicago, IL, United States.

Research output: Contribution to conferencePaper

Huang, H, Alekseev, I, Bunce, G, Bruner, N, Deshpande, A, Goto, Y, Fields, D, Imai, K, Ishihara, M, Kanavets, V, Kurita, K, Li, Z, Lozowski, B, MacKay, W, Mahler, G, Makdisi, Y, Rescia, S, Roser, T, Saito, N, Spinka, H, Svirida, D, Tojo, J, Underwood, D, Wang, H, Zhang, W & Zhao, L 2001, 'A new relative proton polarimeter for RHIC' Paper presented at 2001 Particle Accelerator Conference, Chicago, IL, United States, 6/18/01 - 6/22/01, pp. 2443-2445.
Huang H, Alekseev I, Bunce G, Bruner N, Deshpande A, Goto Y et al. A new relative proton polarimeter for RHIC. 2001. Paper presented at 2001 Particle Accelerator Conference, Chicago, IL, United States.
Huang, Hai ; Alekseev, I. ; Bunce, G. ; Bruner, N. ; Deshpande, A. ; Goto, Y. ; Fields, D. ; Imai, K. ; Ishihara, M. ; Kanavets, V. ; Kurita, K. ; Li, Z. ; Lozowski, B. ; MacKay, W. ; Mahler, G. ; Makdisi, Y. ; Rescia, S. ; Roser, T. ; Saito, N. ; Spinka, H. ; Svirida, D. ; Tojo, Junji ; Underwood, D. ; Wang, H. ; Zhang, W. ; Zhao, L. / A new relative proton polarimeter for RHIC. Paper presented at 2001 Particle Accelerator Conference, Chicago, IL, United States.3 p.
@conference{53e92c699ebc41bb98db547a4fe24a30,
title = "A new relative proton polarimeter for RHIC",
abstract = "An innovative polarimeter based on proton carbon elastic scattering in the Coulomb Nuclear Interference (CNI) region has been installed and commissioned in the Blue ring of RHIC during the first RHIC polarized proton commissioning in September, 2000. The polarimeter consists of ultra-thin carbon targets and four silicon detectors. All elements are in a 1.6 meter vacuum chamber. This paper summarizes the polarimeter design issues and recent commissioning results.",
author = "Hai Huang and I. Alekseev and G. Bunce and N. Bruner and A. Deshpande and Y. Goto and D. Fields and K. Imai and M. Ishihara and V. Kanavets and K. Kurita and Z. Li and B. Lozowski and W. MacKay and G. Mahler and Y. Makdisi and S. Rescia and T. Roser and N. Saito and H. Spinka and D. Svirida and Junji Tojo and D. Underwood and H. Wang and W. Zhang and L. Zhao",
year = "2001",
month = "12",
day = "1",
language = "English",
pages = "2443--2445",
note = "2001 Particle Accelerator Conference ; Conference date: 18-06-2001 Through 22-06-2001",

}

TY - CONF

T1 - A new relative proton polarimeter for RHIC

AU - Huang, Hai

AU - Alekseev, I.

AU - Bunce, G.

AU - Bruner, N.

AU - Deshpande, A.

AU - Goto, Y.

AU - Fields, D.

AU - Imai, K.

AU - Ishihara, M.

AU - Kanavets, V.

AU - Kurita, K.

AU - Li, Z.

AU - Lozowski, B.

AU - MacKay, W.

AU - Mahler, G.

AU - Makdisi, Y.

AU - Rescia, S.

AU - Roser, T.

AU - Saito, N.

AU - Spinka, H.

AU - Svirida, D.

AU - Tojo, Junji

AU - Underwood, D.

AU - Wang, H.

AU - Zhang, W.

AU - Zhao, L.

PY - 2001/12/1

Y1 - 2001/12/1

N2 - An innovative polarimeter based on proton carbon elastic scattering in the Coulomb Nuclear Interference (CNI) region has been installed and commissioned in the Blue ring of RHIC during the first RHIC polarized proton commissioning in September, 2000. The polarimeter consists of ultra-thin carbon targets and four silicon detectors. All elements are in a 1.6 meter vacuum chamber. This paper summarizes the polarimeter design issues and recent commissioning results.

AB - An innovative polarimeter based on proton carbon elastic scattering in the Coulomb Nuclear Interference (CNI) region has been installed and commissioned in the Blue ring of RHIC during the first RHIC polarized proton commissioning in September, 2000. The polarimeter consists of ultra-thin carbon targets and four silicon detectors. All elements are in a 1.6 meter vacuum chamber. This paper summarizes the polarimeter design issues and recent commissioning results.

UR - http://www.scopus.com/inward/record.url?scp=0035569599&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035569599&partnerID=8YFLogxK

M3 - Paper

SP - 2443

EP - 2445

ER -