A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation

Daisuke Ueno, Kei Nakamura, Kousuke Kojima, Takeshi Toyoshima, Hideaki Tanaka, Kazuhiko Ueda, Kiyoshi Koyano, Toshiro Kodama

Research output: Contribution to journalArticle

Abstract

Simultaneous vertical ridge augmentation (VRA) can reduce treatment procedures and surgery time, but the concomitant reduction in primary stability (PS) of a shallow-placed implant imparts risk to its prognosis. Although several studies have reported improvements in PS, there is little information from any simultaneous VRA model. This study aimed to evaluate whether tapered implants with stepwise under-prepared osteotomy could improve the PS of shallow-placed implants in an in vitro model of simultaneous VRA. Tapered implants (Straumann ® Bone Level Tapered implant; BLT) and hybrid implants (Straumann ® Bone Level implant; BL) were investigated in this study. A total of 80 osteotomies of different depths (4, 6, 8, 10 mm) were created in rigid polyurethane foam blocks, and each BLT and BL was inserted by either standard (BLT-S, BL-S) or a stepwise under-prepared (BLT-U, BL-U) osteotomy protocol. The PS was evaluated by measuring maximum insertion torque (IT), implant stability quotient (ISQ), and removal torque (RT). The significance level was set at P < 0.05. There were no significant differences in IT, ISQ or RT when comparing BLT-S and BL-S or BLT-U and BL-U at placement depths of 6 and 8 mm. When comparison was made between osteotomy protocols, IT was significantly greater in BLT-U than in BLT-S at all placement depths. A stepwise under-prepared osteotomy protocol improves initial stability of a tapered implant even in a shallow-placed implant model. BLT-U could be a useful protocol for simultaneous VRA.

Original languageEnglish
Pages (from-to)187-193
Number of pages7
JournalOdontology
Volume106
Issue number2
DOIs
Publication statusPublished - Apr 1 2018

Fingerprint

Torque
Osteotomy
Bone and Bones

All Science Journal Classification (ASJC) codes

  • Dentistry(all)

Cite this

A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants : a preliminary study for simultaneous vertical ridge augmentation. / Ueno, Daisuke; Nakamura, Kei; Kojima, Kousuke; Toyoshima, Takeshi; Tanaka, Hideaki; Ueda, Kazuhiko; Koyano, Kiyoshi; Kodama, Toshiro.

In: Odontology, Vol. 106, No. 2, 01.04.2018, p. 187-193.

Research output: Contribution to journalArticle

Ueno, Daisuke ; Nakamura, Kei ; Kojima, Kousuke ; Toyoshima, Takeshi ; Tanaka, Hideaki ; Ueda, Kazuhiko ; Koyano, Kiyoshi ; Kodama, Toshiro. / A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants : a preliminary study for simultaneous vertical ridge augmentation. In: Odontology. 2018 ; Vol. 106, No. 2. pp. 187-193.
@article{f0d49161b9d942798965457cd7aeb379,
title = "A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation",
abstract = "Simultaneous vertical ridge augmentation (VRA) can reduce treatment procedures and surgery time, but the concomitant reduction in primary stability (PS) of a shallow-placed implant imparts risk to its prognosis. Although several studies have reported improvements in PS, there is little information from any simultaneous VRA model. This study aimed to evaluate whether tapered implants with stepwise under-prepared osteotomy could improve the PS of shallow-placed implants in an in vitro model of simultaneous VRA. Tapered implants (Straumann {\circledR} Bone Level Tapered implant; BLT) and hybrid implants (Straumann {\circledR} Bone Level implant; BL) were investigated in this study. A total of 80 osteotomies of different depths (4, 6, 8, 10 mm) were created in rigid polyurethane foam blocks, and each BLT and BL was inserted by either standard (BLT-S, BL-S) or a stepwise under-prepared (BLT-U, BL-U) osteotomy protocol. The PS was evaluated by measuring maximum insertion torque (IT), implant stability quotient (ISQ), and removal torque (RT). The significance level was set at P < 0.05. There were no significant differences in IT, ISQ or RT when comparing BLT-S and BL-S or BLT-U and BL-U at placement depths of 6 and 8 mm. When comparison was made between osteotomy protocols, IT was significantly greater in BLT-U than in BLT-S at all placement depths. A stepwise under-prepared osteotomy protocol improves initial stability of a tapered implant even in a shallow-placed implant model. BLT-U could be a useful protocol for simultaneous VRA.",
author = "Daisuke Ueno and Kei Nakamura and Kousuke Kojima and Takeshi Toyoshima and Hideaki Tanaka and Kazuhiko Ueda and Kiyoshi Koyano and Toshiro Kodama",
year = "2018",
month = "4",
day = "1",
doi = "10.1007/s10266-017-0316-3",
language = "English",
volume = "106",
pages = "187--193",
journal = "Odontology / the Society of the Nippon Dental University",
issn = "1618-1247",
publisher = "Springer Japan",
number = "2",

}

TY - JOUR

T1 - A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants

T2 - a preliminary study for simultaneous vertical ridge augmentation

AU - Ueno, Daisuke

AU - Nakamura, Kei

AU - Kojima, Kousuke

AU - Toyoshima, Takeshi

AU - Tanaka, Hideaki

AU - Ueda, Kazuhiko

AU - Koyano, Kiyoshi

AU - Kodama, Toshiro

PY - 2018/4/1

Y1 - 2018/4/1

N2 - Simultaneous vertical ridge augmentation (VRA) can reduce treatment procedures and surgery time, but the concomitant reduction in primary stability (PS) of a shallow-placed implant imparts risk to its prognosis. Although several studies have reported improvements in PS, there is little information from any simultaneous VRA model. This study aimed to evaluate whether tapered implants with stepwise under-prepared osteotomy could improve the PS of shallow-placed implants in an in vitro model of simultaneous VRA. Tapered implants (Straumann ® Bone Level Tapered implant; BLT) and hybrid implants (Straumann ® Bone Level implant; BL) were investigated in this study. A total of 80 osteotomies of different depths (4, 6, 8, 10 mm) were created in rigid polyurethane foam blocks, and each BLT and BL was inserted by either standard (BLT-S, BL-S) or a stepwise under-prepared (BLT-U, BL-U) osteotomy protocol. The PS was evaluated by measuring maximum insertion torque (IT), implant stability quotient (ISQ), and removal torque (RT). The significance level was set at P < 0.05. There were no significant differences in IT, ISQ or RT when comparing BLT-S and BL-S or BLT-U and BL-U at placement depths of 6 and 8 mm. When comparison was made between osteotomy protocols, IT was significantly greater in BLT-U than in BLT-S at all placement depths. A stepwise under-prepared osteotomy protocol improves initial stability of a tapered implant even in a shallow-placed implant model. BLT-U could be a useful protocol for simultaneous VRA.

AB - Simultaneous vertical ridge augmentation (VRA) can reduce treatment procedures and surgery time, but the concomitant reduction in primary stability (PS) of a shallow-placed implant imparts risk to its prognosis. Although several studies have reported improvements in PS, there is little information from any simultaneous VRA model. This study aimed to evaluate whether tapered implants with stepwise under-prepared osteotomy could improve the PS of shallow-placed implants in an in vitro model of simultaneous VRA. Tapered implants (Straumann ® Bone Level Tapered implant; BLT) and hybrid implants (Straumann ® Bone Level implant; BL) were investigated in this study. A total of 80 osteotomies of different depths (4, 6, 8, 10 mm) were created in rigid polyurethane foam blocks, and each BLT and BL was inserted by either standard (BLT-S, BL-S) or a stepwise under-prepared (BLT-U, BL-U) osteotomy protocol. The PS was evaluated by measuring maximum insertion torque (IT), implant stability quotient (ISQ), and removal torque (RT). The significance level was set at P < 0.05. There were no significant differences in IT, ISQ or RT when comparing BLT-S and BL-S or BLT-U and BL-U at placement depths of 6 and 8 mm. When comparison was made between osteotomy protocols, IT was significantly greater in BLT-U than in BLT-S at all placement depths. A stepwise under-prepared osteotomy protocol improves initial stability of a tapered implant even in a shallow-placed implant model. BLT-U could be a useful protocol for simultaneous VRA.

UR - http://www.scopus.com/inward/record.url?scp=85026746416&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85026746416&partnerID=8YFLogxK

U2 - 10.1007/s10266-017-0316-3

DO - 10.1007/s10266-017-0316-3

M3 - Article

C2 - 28770416

AN - SCOPUS:85026746416

VL - 106

SP - 187

EP - 193

JO - Odontology / the Society of the Nippon Dental University

JF - Odontology / the Society of the Nippon Dental University

SN - 1618-1247

IS - 2

ER -