A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012

Takashi Miyawaki, Shusaku Hirakawa, Takashi Todaka, Hironori Hirakawa, Tsuguhide Hori, Junboku Kajiwara, Teruaki Hirata, Uchi Hiroshi, Masutaka Furue

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.

Original languageEnglish
Pages (from-to)160-168
Number of pages9
JournalFukuoka igaku zasshi = Hukuoka acta medica
Volume106
Issue number5
Publication statusPublished - May 1 2015

Fingerprint

Polychlorinated Biphenyls
Oils
Lipids

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Cite this

A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012. / Miyawaki, Takashi; Hirakawa, Shusaku; Todaka, Takashi; Hirakawa, Hironori; Hori, Tsuguhide; Kajiwara, Junboku; Hirata, Teruaki; Hiroshi, Uchi; Furue, Masutaka.

In: Fukuoka igaku zasshi = Hukuoka acta medica, Vol. 106, No. 5, 01.05.2015, p. 160-168.

Research output: Contribution to journalArticle

Miyawaki, T, Hirakawa, S, Todaka, T, Hirakawa, H, Hori, T, Kajiwara, J, Hirata, T, Hiroshi, U & Furue, M 2015, 'A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012', Fukuoka igaku zasshi = Hukuoka acta medica, vol. 106, no. 5, pp. 160-168.
Miyawaki, Takashi ; Hirakawa, Shusaku ; Todaka, Takashi ; Hirakawa, Hironori ; Hori, Tsuguhide ; Kajiwara, Junboku ; Hirata, Teruaki ; Hiroshi, Uchi ; Furue, Masutaka. / A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012. In: Fukuoka igaku zasshi = Hukuoka acta medica. 2015 ; Vol. 106, No. 5. pp. 160-168.
@article{59e5614281384061a93755671ebaf5b6,
title = "A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012",
abstract = "In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.",
author = "Takashi Miyawaki and Shusaku Hirakawa and Takashi Todaka and Hironori Hirakawa and Tsuguhide Hori and Junboku Kajiwara and Teruaki Hirata and Uchi Hiroshi and Masutaka Furue",
year = "2015",
month = "5",
day = "1",
language = "English",
volume = "106",
pages = "160--168",
journal = "Fukuoka Acta Medica",
issn = "0016-254X",
publisher = "福岡医学会",
number = "5",

}

TY - JOUR

T1 - A Study on Polychlorinated Biphenyls Specifically--Accumulated in Blood of Yusho Patients Collected from Medical Check-Ups in 2012

AU - Miyawaki, Takashi

AU - Hirakawa, Shusaku

AU - Todaka, Takashi

AU - Hirakawa, Hironori

AU - Hori, Tsuguhide

AU - Kajiwara, Junboku

AU - Hirata, Teruaki

AU - Hiroshi, Uchi

AU - Furue, Masutaka

PY - 2015/5/1

Y1 - 2015/5/1

N2 - In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.

AB - In this study, we analyzed polychlorinated biphenyls (PCBs) in the blood of Yusho patients collected from medical check-ups, which were conducted in 2012. The results show that 65 PCB isomers, not including non-ortho PCBs, were detected in the blood samples, and the total concentration was 620 ng g(-1) lipid. This value was comparable to the concentration in blood samples collected in 2005, and indicated that PCB concentrations in Yusho patients remained unchanged from 2005 to 2012. Here, we focused on major and specific PCB isomers in the blood samples of Yusho patients and normal controls. Examples of the former include hexaCB-153, hexaCB-138, and heptaCB-180, which are detected in human blood, while the latter include hexaCB-156, hexaCB-157, and heptaCB-189, and are highly detected in the blood of Yusho patients. Additionally, we tried to determine why the specific isomers were highly accumulated in the blood of Yusho patients as compared to the normal controls. We therefore analyzed these isomers in the contaminated rice oil, and found that the concentrations of hexaCB-156, hexaCB-157, and heptaCB-189 were 1800, 450, and 190 ng g(-1), respectively. Notably, previous studies indicated that these isomers might not be easily metabolized in humans. Therefore, these findings demonstrated that these isomers were highly accumulated in the blood of Yusho patients.

UR - http://www.scopus.com/inward/record.url?scp=84940970053&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84940970053&partnerID=8YFLogxK

M3 - Article

C2 - 26226679

AN - SCOPUS:84940970053

VL - 106

SP - 160

EP - 168

JO - Fukuoka Acta Medica

JF - Fukuoka Acta Medica

SN - 0016-254X

IS - 5

ER -