A study on the determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates using tedlar bag static methods

Yasuyuki Hoshika, Mariko Nishikitani, Kazuhito Yokoyama, Shunichi Araki

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates was carried out by odor panel test (Japanese students 18-22 years old;6 males and a female) using 10-liter Tedlar bag static method. The trace concentrations of n- and iso-amyl acetates in the Tedlar bag were determined by gas chromatography and an odor sensor (SnO2 type). The odor recognition threshold values of amyl acetates were 7.70 ppm for n-amyl and 1.50 ppm for iso-amyl. The odor quality from several odor panels were evaluated, such as a binder solvent-like, aqueous paint, stimuli, fruity, aromatic, ether-like, gasoline-like, pungent, minty, sour, petroleumlike, respectively.

Original languageEnglish
Pages (from-to)505-508
Number of pages4
JournalAnalytical Sciences
Volume13
Issue numberSUPPL.
Publication statusPublished - 1997
Externally publishedYes

Fingerprint

Polyethylene Terephthalates
Odors
Paint
Gas chromatography
Ether
Binders
Gasoline
amyl acetate
Students
Sensors

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

A study on the determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates using tedlar bag static methods. / Hoshika, Yasuyuki; Nishikitani, Mariko; Yokoyama, Kazuhito; Araki, Shunichi.

In: Analytical Sciences, Vol. 13, No. SUPPL., 1997, p. 505-508.

Research output: Contribution to journalArticle

@article{83b30a7680c94e8cafec9fcd51f2078e,
title = "A study on the determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates using tedlar bag static methods",
abstract = "The determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates was carried out by odor panel test (Japanese students 18-22 years old;6 males and a female) using 10-liter Tedlar bag static method. The trace concentrations of n- and iso-amyl acetates in the Tedlar bag were determined by gas chromatography and an odor sensor (SnO2 type). The odor recognition threshold values of amyl acetates were 7.70 ppm for n-amyl and 1.50 ppm for iso-amyl. The odor quality from several odor panels were evaluated, such as a binder solvent-like, aqueous paint, stimuli, fruity, aromatic, ether-like, gasoline-like, pungent, minty, sour, petroleumlike, respectively.",
author = "Yasuyuki Hoshika and Mariko Nishikitani and Kazuhito Yokoyama and Shunichi Araki",
year = "1997",
language = "English",
volume = "13",
pages = "505--508",
journal = "Analytical Sciences",
issn = "0910-6340",
publisher = "The Japan Society for Analytical Chemistry",
number = "SUPPL.",

}

TY - JOUR

T1 - A study on the determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates using tedlar bag static methods

AU - Hoshika, Yasuyuki

AU - Nishikitani, Mariko

AU - Yokoyama, Kazuhito

AU - Araki, Shunichi

PY - 1997

Y1 - 1997

N2 - The determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates was carried out by odor panel test (Japanese students 18-22 years old;6 males and a female) using 10-liter Tedlar bag static method. The trace concentrations of n- and iso-amyl acetates in the Tedlar bag were determined by gas chromatography and an odor sensor (SnO2 type). The odor recognition threshold values of amyl acetates were 7.70 ppm for n-amyl and 1.50 ppm for iso-amyl. The odor quality from several odor panels were evaluated, such as a binder solvent-like, aqueous paint, stimuli, fruity, aromatic, ether-like, gasoline-like, pungent, minty, sour, petroleumlike, respectively.

AB - The determination of odor recognition threshold values of n- and iso-amyl (pentyl) acetates was carried out by odor panel test (Japanese students 18-22 years old;6 males and a female) using 10-liter Tedlar bag static method. The trace concentrations of n- and iso-amyl acetates in the Tedlar bag were determined by gas chromatography and an odor sensor (SnO2 type). The odor recognition threshold values of amyl acetates were 7.70 ppm for n-amyl and 1.50 ppm for iso-amyl. The odor quality from several odor panels were evaluated, such as a binder solvent-like, aqueous paint, stimuli, fruity, aromatic, ether-like, gasoline-like, pungent, minty, sour, petroleumlike, respectively.

UR - http://www.scopus.com/inward/record.url?scp=19044385699&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=19044385699&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:19044385699

VL - 13

SP - 505

EP - 508

JO - Analytical Sciences

JF - Analytical Sciences

SN - 0910-6340

IS - SUPPL.

ER -