Accurate and robust systolic myocardial T1 mapping using saturation recovery with individualized delay time: comparison with diastolic T1 mapping

Hideo Arai, Masateru Kawakubo, Kenichi Sanui, Hiroshi Nishimura, Toshiaki Kadokami

Research output: Contribution to journalArticle

Abstract

T1 mapping data are generally acquired in patients’ diastolic phase, wherein their myocardium is the thinnest in the cardiac cycle. However, the analysis of the thin myocardium may cause errors in image registrations and settings related to the region of interest. In this study, we validated systolic T1 mapping using the saturation recovery with individualized delay time (SR-IDT) method and compared it with conventional diastolic T1 mapping. Both diastolic and systolic T1 mappings were performed in the mid-ventricular plane in 10 healthy volunteers (35 ± 9 years, 9 males) and 29 consecutive patients with cardiac diseases (68 ± 14 years, 19 males). Comparison of the myocardial T1 value at diastole and systole was performed with both the Pearson correlation coefficient (r) and the Bland–Altman analysis. Additionally, the systolic myocardial T1 value was compared between the volunteers and patients by using Tukey’s test. Pearson correlation analysis demonstrated a strong positive correlation between diastolic and systolic T1 values (r = 0.88, P < 0.001). The Bland–Altman plot suggested that left ventricular T1 values in the diastole and systole showed high agreement (mean difference and 95% limits of agreement = 17 ± 104 ms). Further, systolic T1 values with SR-IDT in patients in the late gadolinium enhancement (LGE) group were significantly higher than those in the control group (1585 ± 118 ms vs 1469 ± 69 ms; P = 0.024). Therefore, the proposed systolic T1 mapping with the SR-IDT, which was validated with respect to the conventional diastolic method, is a useful clinical tool for the quantitative characterization of the myocardium.

Original languageEnglish
Pages (from-to)415-422
Number of pages8
JournalRadiological physics and technology
Volume11
Issue number4
DOIs
Publication statusPublished - Dec 1 2018

Fingerprint

time lag
myocardium
recovery
saturation
Myocardium
diastole
systole
Diastole
Systole
Gadolinium
Volunteers
Heart Diseases
gadolinium
Healthy Volunteers
correlation coefficients
Control Groups
plots
cycles
augmentation
causes

All Science Journal Classification (ASJC) codes

  • Radiation
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Radiology Nuclear Medicine and imaging

Cite this

Accurate and robust systolic myocardial T1 mapping using saturation recovery with individualized delay time : comparison with diastolic T1 mapping. / Arai, Hideo; Kawakubo, Masateru; Sanui, Kenichi; Nishimura, Hiroshi; Kadokami, Toshiaki.

In: Radiological physics and technology, Vol. 11, No. 4, 01.12.2018, p. 415-422.

Research output: Contribution to journalArticle

@article{a38460c24f694b7b800e27586092a525,
title = "Accurate and robust systolic myocardial T1 mapping using saturation recovery with individualized delay time: comparison with diastolic T1 mapping",
abstract = "T1 mapping data are generally acquired in patients’ diastolic phase, wherein their myocardium is the thinnest in the cardiac cycle. However, the analysis of the thin myocardium may cause errors in image registrations and settings related to the region of interest. In this study, we validated systolic T1 mapping using the saturation recovery with individualized delay time (SR-IDT) method and compared it with conventional diastolic T1 mapping. Both diastolic and systolic T1 mappings were performed in the mid-ventricular plane in 10 healthy volunteers (35 ± 9 years, 9 males) and 29 consecutive patients with cardiac diseases (68 ± 14 years, 19 males). Comparison of the myocardial T1 value at diastole and systole was performed with both the Pearson correlation coefficient (r) and the Bland–Altman analysis. Additionally, the systolic myocardial T1 value was compared between the volunteers and patients by using Tukey’s test. Pearson correlation analysis demonstrated a strong positive correlation between diastolic and systolic T1 values (r = 0.88, P < 0.001). The Bland–Altman plot suggested that left ventricular T1 values in the diastole and systole showed high agreement (mean difference and 95{\%} limits of agreement = 17 ± 104 ms). Further, systolic T1 values with SR-IDT in patients in the late gadolinium enhancement (LGE) group were significantly higher than those in the control group (1585 ± 118 ms vs 1469 ± 69 ms; P = 0.024). Therefore, the proposed systolic T1 mapping with the SR-IDT, which was validated with respect to the conventional diastolic method, is a useful clinical tool for the quantitative characterization of the myocardium.",
author = "Hideo Arai and Masateru Kawakubo and Kenichi Sanui and Hiroshi Nishimura and Toshiaki Kadokami",
year = "2018",
month = "12",
day = "1",
doi = "10.1007/s12194-018-0478-x",
language = "English",
volume = "11",
pages = "415--422",
journal = "Radiological Physics and Technology",
issn = "1865-0333",
publisher = "Springer Japan",
number = "4",

}

TY - JOUR

T1 - Accurate and robust systolic myocardial T1 mapping using saturation recovery with individualized delay time

T2 - comparison with diastolic T1 mapping

AU - Arai, Hideo

AU - Kawakubo, Masateru

AU - Sanui, Kenichi

AU - Nishimura, Hiroshi

AU - Kadokami, Toshiaki

PY - 2018/12/1

Y1 - 2018/12/1

N2 - T1 mapping data are generally acquired in patients’ diastolic phase, wherein their myocardium is the thinnest in the cardiac cycle. However, the analysis of the thin myocardium may cause errors in image registrations and settings related to the region of interest. In this study, we validated systolic T1 mapping using the saturation recovery with individualized delay time (SR-IDT) method and compared it with conventional diastolic T1 mapping. Both diastolic and systolic T1 mappings were performed in the mid-ventricular plane in 10 healthy volunteers (35 ± 9 years, 9 males) and 29 consecutive patients with cardiac diseases (68 ± 14 years, 19 males). Comparison of the myocardial T1 value at diastole and systole was performed with both the Pearson correlation coefficient (r) and the Bland–Altman analysis. Additionally, the systolic myocardial T1 value was compared between the volunteers and patients by using Tukey’s test. Pearson correlation analysis demonstrated a strong positive correlation between diastolic and systolic T1 values (r = 0.88, P < 0.001). The Bland–Altman plot suggested that left ventricular T1 values in the diastole and systole showed high agreement (mean difference and 95% limits of agreement = 17 ± 104 ms). Further, systolic T1 values with SR-IDT in patients in the late gadolinium enhancement (LGE) group were significantly higher than those in the control group (1585 ± 118 ms vs 1469 ± 69 ms; P = 0.024). Therefore, the proposed systolic T1 mapping with the SR-IDT, which was validated with respect to the conventional diastolic method, is a useful clinical tool for the quantitative characterization of the myocardium.

AB - T1 mapping data are generally acquired in patients’ diastolic phase, wherein their myocardium is the thinnest in the cardiac cycle. However, the analysis of the thin myocardium may cause errors in image registrations and settings related to the region of interest. In this study, we validated systolic T1 mapping using the saturation recovery with individualized delay time (SR-IDT) method and compared it with conventional diastolic T1 mapping. Both diastolic and systolic T1 mappings were performed in the mid-ventricular plane in 10 healthy volunteers (35 ± 9 years, 9 males) and 29 consecutive patients with cardiac diseases (68 ± 14 years, 19 males). Comparison of the myocardial T1 value at diastole and systole was performed with both the Pearson correlation coefficient (r) and the Bland–Altman analysis. Additionally, the systolic myocardial T1 value was compared between the volunteers and patients by using Tukey’s test. Pearson correlation analysis demonstrated a strong positive correlation between diastolic and systolic T1 values (r = 0.88, P < 0.001). The Bland–Altman plot suggested that left ventricular T1 values in the diastole and systole showed high agreement (mean difference and 95% limits of agreement = 17 ± 104 ms). Further, systolic T1 values with SR-IDT in patients in the late gadolinium enhancement (LGE) group were significantly higher than those in the control group (1585 ± 118 ms vs 1469 ± 69 ms; P = 0.024). Therefore, the proposed systolic T1 mapping with the SR-IDT, which was validated with respect to the conventional diastolic method, is a useful clinical tool for the quantitative characterization of the myocardium.

UR - http://www.scopus.com/inward/record.url?scp=85053752773&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053752773&partnerID=8YFLogxK

U2 - 10.1007/s12194-018-0478-x

DO - 10.1007/s12194-018-0478-x

M3 - Article

C2 - 30251197

AN - SCOPUS:85053752773

VL - 11

SP - 415

EP - 422

JO - Radiological Physics and Technology

JF - Radiological Physics and Technology

SN - 1865-0333

IS - 4

ER -