Active noise control assuming quiet zone move

Ikuma Ikeda, Shinya Kijimoto, Koichi Matsuda, Yosuke Koba, Toshihiko Higashi

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Active noise control (ANC) in 3-dimensional sound field, e.g. an office room, is investigated in this paper. Since the size of the controlled area normally depends on the wave length of the target noise, it is difficult to control in the whole room using ANC technique. Instead, around-head-control is investigated in this paper. To realize the around-head-control, an evaluation point is required to correspond with the head movement while controlling. However, the evaluation point movement while controlling has not been considered in a conventional ANC. Against this problem, the new algorithm is proposed in this paper. The algorithm calculates filters as function of position by using a Time-Delay filter and a Distance-Attenuation coefficient. The Time-Delay filter and the DistanceAttenuation coefficient are calculated from the position of the evaluation point. Computer simulations with acoustic characteristics in an anechoic chamber and an ordinary room are carried out. The validity of the proposed algorithm is shown from these simulations.

Original languageEnglish
Pages (from-to)1273-1280
Number of pages8
JournalNihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
Volume74
Issue number5
Publication statusPublished - May 1 2008

Fingerprint

Active noise control
Time delay
Anechoic chambers
Acoustic fields
Acoustics
Wavelength
Computer simulation

All Science Journal Classification (ASJC) codes

  • Mechanics of Materials
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering

Cite this

Active noise control assuming quiet zone move. / Ikeda, Ikuma; Kijimoto, Shinya; Matsuda, Koichi; Koba, Yosuke; Higashi, Toshihiko.

In: Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, Vol. 74, No. 5, 01.05.2008, p. 1273-1280.

Research output: Contribution to journalArticle

Ikeda, Ikuma ; Kijimoto, Shinya ; Matsuda, Koichi ; Koba, Yosuke ; Higashi, Toshihiko. / Active noise control assuming quiet zone move. In: Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C. 2008 ; Vol. 74, No. 5. pp. 1273-1280.
@article{a9833813506d45ef83eff87da6effb00,
title = "Active noise control assuming quiet zone move",
abstract = "Active noise control (ANC) in 3-dimensional sound field, e.g. an office room, is investigated in this paper. Since the size of the controlled area normally depends on the wave length of the target noise, it is difficult to control in the whole room using ANC technique. Instead, around-head-control is investigated in this paper. To realize the around-head-control, an evaluation point is required to correspond with the head movement while controlling. However, the evaluation point movement while controlling has not been considered in a conventional ANC. Against this problem, the new algorithm is proposed in this paper. The algorithm calculates filters as function of position by using a Time-Delay filter and a Distance-Attenuation coefficient. The Time-Delay filter and the DistanceAttenuation coefficient are calculated from the position of the evaluation point. Computer simulations with acoustic characteristics in an anechoic chamber and an ordinary room are carried out. The validity of the proposed algorithm is shown from these simulations.",
author = "Ikuma Ikeda and Shinya Kijimoto and Koichi Matsuda and Yosuke Koba and Toshihiko Higashi",
year = "2008",
month = "5",
day = "1",
language = "English",
volume = "74",
pages = "1273--1280",
journal = "Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C",
issn = "0387-5024",
publisher = "The Japan Society of Mechanical Engineers",
number = "5",

}

TY - JOUR

T1 - Active noise control assuming quiet zone move

AU - Ikeda, Ikuma

AU - Kijimoto, Shinya

AU - Matsuda, Koichi

AU - Koba, Yosuke

AU - Higashi, Toshihiko

PY - 2008/5/1

Y1 - 2008/5/1

N2 - Active noise control (ANC) in 3-dimensional sound field, e.g. an office room, is investigated in this paper. Since the size of the controlled area normally depends on the wave length of the target noise, it is difficult to control in the whole room using ANC technique. Instead, around-head-control is investigated in this paper. To realize the around-head-control, an evaluation point is required to correspond with the head movement while controlling. However, the evaluation point movement while controlling has not been considered in a conventional ANC. Against this problem, the new algorithm is proposed in this paper. The algorithm calculates filters as function of position by using a Time-Delay filter and a Distance-Attenuation coefficient. The Time-Delay filter and the DistanceAttenuation coefficient are calculated from the position of the evaluation point. Computer simulations with acoustic characteristics in an anechoic chamber and an ordinary room are carried out. The validity of the proposed algorithm is shown from these simulations.

AB - Active noise control (ANC) in 3-dimensional sound field, e.g. an office room, is investigated in this paper. Since the size of the controlled area normally depends on the wave length of the target noise, it is difficult to control in the whole room using ANC technique. Instead, around-head-control is investigated in this paper. To realize the around-head-control, an evaluation point is required to correspond with the head movement while controlling. However, the evaluation point movement while controlling has not been considered in a conventional ANC. Against this problem, the new algorithm is proposed in this paper. The algorithm calculates filters as function of position by using a Time-Delay filter and a Distance-Attenuation coefficient. The Time-Delay filter and the DistanceAttenuation coefficient are calculated from the position of the evaluation point. Computer simulations with acoustic characteristics in an anechoic chamber and an ordinary room are carried out. The validity of the proposed algorithm is shown from these simulations.

UR - http://www.scopus.com/inward/record.url?scp=49249109207&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=49249109207&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:49249109207

VL - 74

SP - 1273

EP - 1280

JO - Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

JF - Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

SN - 0387-5024

IS - 5

ER -