T1 - Advanced integrated cooling systems for thermal management in data centers
AU - Abe, Yoshiyuki
AU - Fukagaya, Masato
AU - Kitagawa, Takashi
AU - Ohta, Haruhiko
AU - Shinmoto, Yasuhisa
AU - Sato, Masahide
AU - Iimura, Ken Ichi
PY - 2010/6/30
Y1 - 2010/6/30
N2 - For a drastic energy conservation in data centers (more than 30%), a new advanced concept of thermal management systems of integrated cooling network in server racks is proposed, and a series of developmental studies toward the realization of the concept have been conducted. The concept consists of the following technological items: - Plug-in thermal network cables, - Narrow channel heat exchangers (single-phase and two-phase), - Thin flat-type heat pipes, - Development of nano-fluids for heat transfer enhancement. In this concept, CPUs in server racks are directly cooled with the aid of advanced 1.5 mm thick flat-type heat pipes or 3 mm thick narrow channel heat exchangers, though CPUs in server racks, at present, are cooled down with massive heat sinks by forced air flow in the racks. In the case of heat pipes, condensation regions are cooled by either single-phase or two-phase narrow channel heat sink instead of air-cooled finned heat sink. These cooling units are accommodated in server racks. In addition, plug-in thermal network cables, in which a working fluid for narrow channel heat exchangers is running, are integrated among server racks, and thermal energy dissipated in server racks are inclusively merged and managed by the thermal network cables. The working fluid heated up by the dissipated heat is recuperated in an outdoor cooling system. An attempt at the applications of silver nano-fluids as a working fluid in heat pipes and thermal network is also conducted in the present study. Silver nano-fluids are thermochemically synthesized by a microwave heating technique, which allows for superior stable suspension characteristics.
AB - For a drastic energy conservation in data centers (more than 30%), a new advanced concept of thermal management systems of integrated cooling network in server racks is proposed, and a series of developmental studies toward the realization of the concept have been conducted. The concept consists of the following technological items: - Plug-in thermal network cables, - Narrow channel heat exchangers (single-phase and two-phase), - Thin flat-type heat pipes, - Development of nano-fluids for heat transfer enhancement. In this concept, CPUs in server racks are directly cooled with the aid of advanced 1.5 mm thick flat-type heat pipes or 3 mm thick narrow channel heat exchangers, though CPUs in server racks, at present, are cooled down with massive heat sinks by forced air flow in the racks. In the case of heat pipes, condensation regions are cooled by either single-phase or two-phase narrow channel heat sink instead of air-cooled finned heat sink. These cooling units are accommodated in server racks. In addition, plug-in thermal network cables, in which a working fluid for narrow channel heat exchangers is running, are integrated among server racks, and thermal energy dissipated in server racks are inclusively merged and managed by the thermal network cables. The working fluid heated up by the dissipated heat is recuperated in an outdoor cooling system. An attempt at the applications of silver nano-fluids as a working fluid in heat pipes and thermal network is also conducted in the present study. Silver nano-fluids are thermochemically synthesized by a microwave heating technique, which allows for superior stable suspension characteristics.
UR - http://www.scopus.com/inward/record.url?scp=77953923746&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77953923746&partnerID=8YFLogxK
U2 - 10.1115/InterPACK2009-89009
DO - 10.1115/InterPACK2009-89009
M3 - Conference contribution
AN - SCOPUS:77953923746
SN - 9780791843604
T3 - Proceedings of the ASME InterPack Conference 2009, IPACK2009
SP - 619
EP - 624
BT - Proceedings of the ASME InterPack Conference 2009, IPACK2009
T2 - 2009 ASME InterPack Conference, IPACK2009
Y2 - 19 July 2009 through 23 July 2009
ER -