Early detection and removal of adenomatous polyps reduces colorectal cancer death. However, many studies have reported that up to 20% of adenomas can be missed during colonoscopy. To improve visualization and reduce the blind spot of the colonic mucosa for an increase in the adenoma detection rate, many endoscopic techniques and technologies have been developed. The benefit of the high-definition endoscope for improving adenoma and polyp detection is marginal. Wide-angle colonoscope has failed to improve adenoma detection compared to standard colonoscopy. Although the cap-assisted colonoscope can reduce cecal intubation times, it does not seem to improve adenoma and polyp detection. The diagnostic accuracy of the colon capsule endoscope is low compared to the conventional colonoscope. Third Eye® retroscope®, which provides additional retrograde viewing, has revealed significant improvement in adenoma and polyp detection compared to standard colonoscopy. However, this device increases procedural times. Recently developed full-spectrum endoscopy colonoscope and extra-wide-angle-view colonoscope have demonstrated a significantly lower miss rate of polyps. However, clinical trials are mandatory to determine the efficacy of these novel technologies for cancer screening. In addition, education and training for these novel techniques and technologies should seriously be considered to improve adenoma and polyp detection.

Original languageEnglish
Pages (from-to)40-44
Number of pages5
JournalDigestive Endoscopy
Volume27
Issue numberS1
DOIs
Publication statusPublished - Apr 1 2015

Fingerprint

Colonoscopy
Colonoscopes
Polyps
Adenoma
Technology
Capsule Endoscopes
Adenomatous Polyps
Endoscopes
Optic Disk
Early Detection of Cancer
Intubation
Endoscopy
Colorectal Neoplasms
Teaching
Colon
Mucous Membrane
Clinical Trials
Education
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging
  • Gastroenterology

Cite this

Advanced technology for the improvement of adenoma and polyp detection during colonoscopy. / Moriyama, Tomohiko; Uraoka, Toshio; Esaki, Motohiro; Matsumoto, Takayuki.

In: Digestive Endoscopy, Vol. 27, No. S1, 01.04.2015, p. 40-44.

Research output: Contribution to journalArticle

Moriyama, Tomohiko ; Uraoka, Toshio ; Esaki, Motohiro ; Matsumoto, Takayuki. / Advanced technology for the improvement of adenoma and polyp detection during colonoscopy. In: Digestive Endoscopy. 2015 ; Vol. 27, No. S1. pp. 40-44.
@article{f7bc3ab1fb1b45dcbafd4af209641fac,
title = "Advanced technology for the improvement of adenoma and polyp detection during colonoscopy",
abstract = "Early detection and removal of adenomatous polyps reduces colorectal cancer death. However, many studies have reported that up to 20{\%} of adenomas can be missed during colonoscopy. To improve visualization and reduce the blind spot of the colonic mucosa for an increase in the adenoma detection rate, many endoscopic techniques and technologies have been developed. The benefit of the high-definition endoscope for improving adenoma and polyp detection is marginal. Wide-angle colonoscope has failed to improve adenoma detection compared to standard colonoscopy. Although the cap-assisted colonoscope can reduce cecal intubation times, it does not seem to improve adenoma and polyp detection. The diagnostic accuracy of the colon capsule endoscope is low compared to the conventional colonoscope. Third Eye{\circledR} retroscope{\circledR}, which provides additional retrograde viewing, has revealed significant improvement in adenoma and polyp detection compared to standard colonoscopy. However, this device increases procedural times. Recently developed full-spectrum endoscopy colonoscope and extra-wide-angle-view colonoscope have demonstrated a significantly lower miss rate of polyps. However, clinical trials are mandatory to determine the efficacy of these novel technologies for cancer screening. In addition, education and training for these novel techniques and technologies should seriously be considered to improve adenoma and polyp detection.",
author = "Tomohiko Moriyama and Toshio Uraoka and Motohiro Esaki and Takayuki Matsumoto",
year = "2015",
month = "4",
day = "1",
doi = "10.1111/den.12428",
language = "English",
volume = "27",
pages = "40--44",
journal = "Digestive Endoscopy",
issn = "0915-5635",
publisher = "Wiley-Blackwell",
number = "S1",

}

TY - JOUR

T1 - Advanced technology for the improvement of adenoma and polyp detection during colonoscopy

AU - Moriyama, Tomohiko

AU - Uraoka, Toshio

AU - Esaki, Motohiro

AU - Matsumoto, Takayuki

PY - 2015/4/1

Y1 - 2015/4/1

N2 - Early detection and removal of adenomatous polyps reduces colorectal cancer death. However, many studies have reported that up to 20% of adenomas can be missed during colonoscopy. To improve visualization and reduce the blind spot of the colonic mucosa for an increase in the adenoma detection rate, many endoscopic techniques and technologies have been developed. The benefit of the high-definition endoscope for improving adenoma and polyp detection is marginal. Wide-angle colonoscope has failed to improve adenoma detection compared to standard colonoscopy. Although the cap-assisted colonoscope can reduce cecal intubation times, it does not seem to improve adenoma and polyp detection. The diagnostic accuracy of the colon capsule endoscope is low compared to the conventional colonoscope. Third Eye® retroscope®, which provides additional retrograde viewing, has revealed significant improvement in adenoma and polyp detection compared to standard colonoscopy. However, this device increases procedural times. Recently developed full-spectrum endoscopy colonoscope and extra-wide-angle-view colonoscope have demonstrated a significantly lower miss rate of polyps. However, clinical trials are mandatory to determine the efficacy of these novel technologies for cancer screening. In addition, education and training for these novel techniques and technologies should seriously be considered to improve adenoma and polyp detection.

AB - Early detection and removal of adenomatous polyps reduces colorectal cancer death. However, many studies have reported that up to 20% of adenomas can be missed during colonoscopy. To improve visualization and reduce the blind spot of the colonic mucosa for an increase in the adenoma detection rate, many endoscopic techniques and technologies have been developed. The benefit of the high-definition endoscope for improving adenoma and polyp detection is marginal. Wide-angle colonoscope has failed to improve adenoma detection compared to standard colonoscopy. Although the cap-assisted colonoscope can reduce cecal intubation times, it does not seem to improve adenoma and polyp detection. The diagnostic accuracy of the colon capsule endoscope is low compared to the conventional colonoscope. Third Eye® retroscope®, which provides additional retrograde viewing, has revealed significant improvement in adenoma and polyp detection compared to standard colonoscopy. However, this device increases procedural times. Recently developed full-spectrum endoscopy colonoscope and extra-wide-angle-view colonoscope have demonstrated a significantly lower miss rate of polyps. However, clinical trials are mandatory to determine the efficacy of these novel technologies for cancer screening. In addition, education and training for these novel techniques and technologies should seriously be considered to improve adenoma and polyp detection.

UR - http://www.scopus.com/inward/record.url?scp=84926473660&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84926473660&partnerID=8YFLogxK

U2 - 10.1111/den.12428

DO - 10.1111/den.12428

M3 - Article

C2 - 25556542

AN - SCOPUS:84926473660

VL - 27

SP - 40

EP - 44

JO - Digestive Endoscopy

JF - Digestive Endoscopy

SN - 0915-5635

IS - S1

ER -