An application of contra-rotating rotors, consisting of front and rear rotors rotating in the opposite direction from each other, has been proposed against a demand for developing a higher specific speed axial flow pump with a more compact structure, higher efficiency and higher cavitation performance. As axial flow pumps are used for standby operations of air-lock and air/water mixing discharge to prevent floods, air/water two-phase flow performance of the contra-rotating pump has to be also investigated. In the present paper, therefore, experimental results on air/water two-phase flow performance of a test pump with contra-rotating rotors are shown and compared with those of a conventional axial flow pump, consisting of a front rotor and a rear stator. Even under two-phase flow conditions head characteristic curve of the contra-rotating type has a more strongly negative slope than that of the conventional type. The contra-rotating type maintains higher head and higher efficiency even in the low flow rate range and vice versa in the high flow rate range. This result will be discussed by considering the change of outlet flow from front rotor due to two-phase flow with the help of observed air behavior in the rotors. Then effects of changes of rear rotor rotational speed different from front rotor speed, which is an advantage of the contra-rotating axial flow pump, on two-phase flow performance are examined. Under the condition of constant ratio of air to water flow rates, the head rise of the rear rotor linearly increases with rear rotor rotational speed. Air/water two-phase flow performance of the contra-rotating axial flow pump can be improved by this control procedure for the rear rotor rotational speed.

Original languageEnglish
Title of host publicationProceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005
Pages1069-1074
Number of pages6
Publication statusPublished - Dec 20 2005
Event2005 ASME Fluids Engineering Division Summer Conference - Houston, TX, United States
Duration: Jun 19 2005Jun 23 2005

Publication series

NameProceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference
Volume1 PART B

Other

Other2005 ASME Fluids Engineering Division Summer Conference
CountryUnited States
CityHouston, TX
Period6/19/056/23/05

Fingerprint

Axial flow
Speed control
Two phase flow
Rotors
Pumps
Air
Water
Flow rate
Cavitation
Discharge (fluid mechanics)
Stators

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Shigemitsu, T., Watanabe, S., Furukawa, A., & Okuma, K. (2005). Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor. In Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005 (pp. 1069-1074). [FEDSM2005-77002] (Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference; Vol. 1 PART B).

Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor. / Shigemitsu, Toru; Watanabe, Satoshi; Furukawa, Akinori; Okuma, Kusuo.

Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005. 2005. p. 1069-1074 FEDSM2005-77002 (Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference; Vol. 1 PART B).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Shigemitsu, T, Watanabe, S, Furukawa, A & Okuma, K 2005, Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor. in Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005., FEDSM2005-77002, Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference, vol. 1 PART B, pp. 1069-1074, 2005 ASME Fluids Engineering Division Summer Conference, Houston, TX, United States, 6/19/05.
Shigemitsu T, Watanabe S, Furukawa A, Okuma K. Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor. In Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005. 2005. p. 1069-1074. FEDSM2005-77002. (Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference).
Shigemitsu, Toru ; Watanabe, Satoshi ; Furukawa, Akinori ; Okuma, Kusuo. / Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor. Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005. 2005. pp. 1069-1074 (Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference).
@inproceedings{99a409ae6523451788285b6d98da047d,
title = "Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor",
abstract = "An application of contra-rotating rotors, consisting of front and rear rotors rotating in the opposite direction from each other, has been proposed against a demand for developing a higher specific speed axial flow pump with a more compact structure, higher efficiency and higher cavitation performance. As axial flow pumps are used for standby operations of air-lock and air/water mixing discharge to prevent floods, air/water two-phase flow performance of the contra-rotating pump has to be also investigated. In the present paper, therefore, experimental results on air/water two-phase flow performance of a test pump with contra-rotating rotors are shown and compared with those of a conventional axial flow pump, consisting of a front rotor and a rear stator. Even under two-phase flow conditions head characteristic curve of the contra-rotating type has a more strongly negative slope than that of the conventional type. The contra-rotating type maintains higher head and higher efficiency even in the low flow rate range and vice versa in the high flow rate range. This result will be discussed by considering the change of outlet flow from front rotor due to two-phase flow with the help of observed air behavior in the rotors. Then effects of changes of rear rotor rotational speed different from front rotor speed, which is an advantage of the contra-rotating axial flow pump, on two-phase flow performance are examined. Under the condition of constant ratio of air to water flow rates, the head rise of the rear rotor linearly increases with rear rotor rotational speed. Air/water two-phase flow performance of the contra-rotating axial flow pump can be improved by this control procedure for the rear rotor rotational speed.",
author = "Toru Shigemitsu and Satoshi Watanabe and Akinori Furukawa and Kusuo Okuma",
year = "2005",
month = "12",
day = "20",
language = "English",
isbn = "0791841987",
series = "Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference",
pages = "1069--1074",
booktitle = "Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005",

}

TY - GEN

T1 - Air/water two-phase flow performance of contra-rotating axial flow pump and rotational speed control of rear rotor

AU - Shigemitsu, Toru

AU - Watanabe, Satoshi

AU - Furukawa, Akinori

AU - Okuma, Kusuo

PY - 2005/12/20

Y1 - 2005/12/20

N2 - An application of contra-rotating rotors, consisting of front and rear rotors rotating in the opposite direction from each other, has been proposed against a demand for developing a higher specific speed axial flow pump with a more compact structure, higher efficiency and higher cavitation performance. As axial flow pumps are used for standby operations of air-lock and air/water mixing discharge to prevent floods, air/water two-phase flow performance of the contra-rotating pump has to be also investigated. In the present paper, therefore, experimental results on air/water two-phase flow performance of a test pump with contra-rotating rotors are shown and compared with those of a conventional axial flow pump, consisting of a front rotor and a rear stator. Even under two-phase flow conditions head characteristic curve of the contra-rotating type has a more strongly negative slope than that of the conventional type. The contra-rotating type maintains higher head and higher efficiency even in the low flow rate range and vice versa in the high flow rate range. This result will be discussed by considering the change of outlet flow from front rotor due to two-phase flow with the help of observed air behavior in the rotors. Then effects of changes of rear rotor rotational speed different from front rotor speed, which is an advantage of the contra-rotating axial flow pump, on two-phase flow performance are examined. Under the condition of constant ratio of air to water flow rates, the head rise of the rear rotor linearly increases with rear rotor rotational speed. Air/water two-phase flow performance of the contra-rotating axial flow pump can be improved by this control procedure for the rear rotor rotational speed.

AB - An application of contra-rotating rotors, consisting of front and rear rotors rotating in the opposite direction from each other, has been proposed against a demand for developing a higher specific speed axial flow pump with a more compact structure, higher efficiency and higher cavitation performance. As axial flow pumps are used for standby operations of air-lock and air/water mixing discharge to prevent floods, air/water two-phase flow performance of the contra-rotating pump has to be also investigated. In the present paper, therefore, experimental results on air/water two-phase flow performance of a test pump with contra-rotating rotors are shown and compared with those of a conventional axial flow pump, consisting of a front rotor and a rear stator. Even under two-phase flow conditions head characteristic curve of the contra-rotating type has a more strongly negative slope than that of the conventional type. The contra-rotating type maintains higher head and higher efficiency even in the low flow rate range and vice versa in the high flow rate range. This result will be discussed by considering the change of outlet flow from front rotor due to two-phase flow with the help of observed air behavior in the rotors. Then effects of changes of rear rotor rotational speed different from front rotor speed, which is an advantage of the contra-rotating axial flow pump, on two-phase flow performance are examined. Under the condition of constant ratio of air to water flow rates, the head rise of the rear rotor linearly increases with rear rotor rotational speed. Air/water two-phase flow performance of the contra-rotating axial flow pump can be improved by this control procedure for the rear rotor rotational speed.

UR - http://www.scopus.com/inward/record.url?scp=28944444429&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28944444429&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:28944444429

SN - 0791841987

SN - 9780791841983

T3 - Proceedings of the American Society of Mechanical Engineers Fluids Engineering Division Summer Conference

SP - 1069

EP - 1074

BT - Proceedings of ASME Fluids Engineering Division Summer Conference, 2005 Symposia, FEDSM2005

ER -