An approximate analysis of axisymmetric stress field by using transmission light flow birefringence technique.

K. Funatsu, Toshihisa Kajiwara

Research output: Contribution to journalArticle

Abstract

A method for analyzing an approximately axisymmetric stress field was established. The extinction angle obtained from the isoclinic pattern was taken to be almost equal to the inclination of the principal axis of a refractive index ellipsoid and the phase difference to be dependent only on local values of the double refractive index. Analysis of the local values of the primary double refractive index was made using an approximate equation. The method was applied to stress analysis of the flow around a sphere constituting an example of an axisymmetric flow field. The assumptions cited were shown to be reasonable and the method expressed effective for approximate stress analysis of axisymmetric flow fields with double refractive indices rising to the axis, if suitable correction for such indices is made. (P.J.B.)

Original languageEnglish
JournalKagaku Kogaku Ronbunshu
Volume12
Issue number5 , Sep. 1986, p.575-581.
Publication statusPublished - Jan 1 1986
Externally publishedYes

Fingerprint

Light transmission
Birefringence
Refractive index
Stress analysis
Flow fields

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

An approximate analysis of axisymmetric stress field by using transmission light flow birefringence technique. / Funatsu, K.; Kajiwara, Toshihisa.

In: Kagaku Kogaku Ronbunshu, Vol. 12, No. 5 , Sep. 1986, p.575-581., 01.01.1986.

Research output: Contribution to journalArticle

@article{b413d1ee134242778ca24ae72d72ad2a,
title = "An approximate analysis of axisymmetric stress field by using transmission light flow birefringence technique.",
abstract = "A method for analyzing an approximately axisymmetric stress field was established. The extinction angle obtained from the isoclinic pattern was taken to be almost equal to the inclination of the principal axis of a refractive index ellipsoid and the phase difference to be dependent only on local values of the double refractive index. Analysis of the local values of the primary double refractive index was made using an approximate equation. The method was applied to stress analysis of the flow around a sphere constituting an example of an axisymmetric flow field. The assumptions cited were shown to be reasonable and the method expressed effective for approximate stress analysis of axisymmetric flow fields with double refractive indices rising to the axis, if suitable correction for such indices is made. (P.J.B.)",
author = "K. Funatsu and Toshihisa Kajiwara",
year = "1986",
month = "1",
day = "1",
language = "English",
volume = "12",
journal = "Kagaku Kogaku Ronbunshu",
issn = "0386-216X",
publisher = "The Society of Chemical Engineers, Japan",
number = "5 , Sep. 1986, p.575-581.",

}

TY - JOUR

T1 - An approximate analysis of axisymmetric stress field by using transmission light flow birefringence technique.

AU - Funatsu, K.

AU - Kajiwara, Toshihisa

PY - 1986/1/1

Y1 - 1986/1/1

N2 - A method for analyzing an approximately axisymmetric stress field was established. The extinction angle obtained from the isoclinic pattern was taken to be almost equal to the inclination of the principal axis of a refractive index ellipsoid and the phase difference to be dependent only on local values of the double refractive index. Analysis of the local values of the primary double refractive index was made using an approximate equation. The method was applied to stress analysis of the flow around a sphere constituting an example of an axisymmetric flow field. The assumptions cited were shown to be reasonable and the method expressed effective for approximate stress analysis of axisymmetric flow fields with double refractive indices rising to the axis, if suitable correction for such indices is made. (P.J.B.)

AB - A method for analyzing an approximately axisymmetric stress field was established. The extinction angle obtained from the isoclinic pattern was taken to be almost equal to the inclination of the principal axis of a refractive index ellipsoid and the phase difference to be dependent only on local values of the double refractive index. Analysis of the local values of the primary double refractive index was made using an approximate equation. The method was applied to stress analysis of the flow around a sphere constituting an example of an axisymmetric flow field. The assumptions cited were shown to be reasonable and the method expressed effective for approximate stress analysis of axisymmetric flow fields with double refractive indices rising to the axis, if suitable correction for such indices is made. (P.J.B.)

UR - http://www.scopus.com/inward/record.url?scp=0022514148&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022514148&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0022514148

VL - 12

JO - Kagaku Kogaku Ronbunshu

JF - Kagaku Kogaku Ronbunshu

SN - 0386-216X

IS - 5 , Sep. 1986, p.575-581.

ER -