Abstract
Problems of synchronous rectification in a parallel-module DC-DC converter system are described. These include excessive power dissipation due to the bidirectional current flow capability of MOSFETs and abnormal oscillation due to the cross coupling of the MOSFETs used as synchronous rectifiers. The abnormal oscillation, which causes excessive voltage stress, is analyzed; the results of which are subsequently confirmed by experiment.
Original language | English |
---|---|
Pages (from-to) | 404-411 |
Number of pages | 8 |
Journal | INTELEC, International Telecommunications Energy Conference (Proceedings) |
Publication status | Published - Dec 1 1998 |
Event | Proceedings of the 1998 20th International Telecommunications Energy Conference, INTELEC - San Francisco, CA, USA Duration: Oct 4 1998 → Oct 8 1998 |
All Science Journal Classification (ASJC) codes
- Energy Engineering and Power Technology
- Electrical and Electronic Engineering