TY - JOUR
T1 - Aortic Insufficiency and Hemocompatibility-related Adverse Events in Patients with Left Ventricular Assist Devices
AU - Imamura, Teruhiko
AU - Kim, Gene
AU - Nitta, Daisuke
AU - Fujino, Takeo
AU - Smith, Bryan
AU - Kalantari, Sara
AU - Nguyen, Ann
AU - Narang, Nikhil
AU - Holzhauser, Luise
AU - Grinstein, Jonathan
AU - Juricek, Colleen
AU - Rodgers, Daniel
AU - Song, Tae
AU - Ota, Takeyoshi
AU - Jeevanandam, Valluvan
AU - Sayer, Gabriel
AU - Uriel, Nir
N1 - Funding Information:
TI receives financial support from Postdoctoral Fellowship for Research Abroad of the Japan Society for the Promotion of Science; NU receives grant support from Abbott and Medtronic; GS is a consultant for Medtronic; VJ is a consultant for Abbott.
Publisher Copyright:
© 2019 Elsevier Inc.
PY - 2019/10
Y1 - 2019/10
N2 - Aim: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of AI on HRAE. Methods and Results: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate of diastolic flow acceleration using Doppler echocardiography of the outflow cannula. Regurgitation fraction was derived from these parameters. Significant AI was defined as regurgitation fraction > 30%. Among 105 patients (median age, 56 years; 76% male), 36 patients (34%) had significant AI. Baseline characteristics were statistically not significantly different between those with and without significant AI except for higher rates of ischemic etiology and atrial fibrillation in the significant AI group (P < 0.05 for both). One-year survival free from HRAE was 44% in patients with AI compared to 67% in patients without significant AI (P = 0.018). The average hemocompatibility score, which defines the net burden of HRAE, was higher in the AI group (1.72 vs 0.64; P = 0.009), due mostly to higher tier I (mild HRAE; P = 0.034) and tier IIIB scores (severe HRAE; P = 0.011). Conclusion: Significant AI, as assessed by Doppler echocardiographic parameters, was associated with HRAE during LVAD support.
AB - Aim: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of AI on HRAE. Methods and Results: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate of diastolic flow acceleration using Doppler echocardiography of the outflow cannula. Regurgitation fraction was derived from these parameters. Significant AI was defined as regurgitation fraction > 30%. Among 105 patients (median age, 56 years; 76% male), 36 patients (34%) had significant AI. Baseline characteristics were statistically not significantly different between those with and without significant AI except for higher rates of ischemic etiology and atrial fibrillation in the significant AI group (P < 0.05 for both). One-year survival free from HRAE was 44% in patients with AI compared to 67% in patients without significant AI (P = 0.018). The average hemocompatibility score, which defines the net burden of HRAE, was higher in the AI group (1.72 vs 0.64; P = 0.009), due mostly to higher tier I (mild HRAE; P = 0.034) and tier IIIB scores (severe HRAE; P = 0.011). Conclusion: Significant AI, as assessed by Doppler echocardiographic parameters, was associated with HRAE during LVAD support.
UR - http://www.scopus.com/inward/record.url?scp=85071678718&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85071678718&partnerID=8YFLogxK
U2 - 10.1016/j.cardfail.2019.08.003
DO - 10.1016/j.cardfail.2019.08.003
M3 - Article
C2 - 31419485
AN - SCOPUS:85071678718
SN - 1071-9164
VL - 25
SP - 787
EP - 794
JO - Journal of Cardiac Failure
JF - Journal of Cardiac Failure
IS - 10
ER -