Abstract
An active-clamp circuit is an effective method to suppress the switching surge and to realize the soft switching in switching dc-dc converters. Recently, the common-source type active-clamp forward converter was presented to enable easy gate drive with a direct connection of the sources of the two n-channel MOS-FET switches. In this paper, we apply the common-source type active-clamp circuit to various kinds of dc-dc converter topologies. The effectiveness of the common-mode noise reduction is experimentally confirmed and its mechanism is explained using an equivalent circuit.
Original language | English |
---|---|
Pages (from-to) | 1321-1326 |
Number of pages | 6 |
Journal | PESC Record - IEEE Annual Power Electronics Specialists Conference |
Volume | 3 |
Publication status | Published - Aug 22 2003 |
Event | 2003 IEEE 34th Annual Power Electronics Specialists Conference - Acapulco, NM, United States Duration: Jun 15 2003 → Jun 19 2003 |
All Science Journal Classification (ASJC) codes
- Modelling and Simulation
- Condensed Matter Physics
- Energy Engineering and Power Technology
- Electrical and Electronic Engineering