Blood compatibility of metal oxide layers on stainless-steel

Kanji Tsuru, Shinji Takemoto, Tatsuhiro Yamamoto, Satoshi Hayakawa, Akiyoshi Osaka, Seisuke Takashima

Research output: Contribution to journalConference article

2 Citations (Scopus)

Abstract

We examined blood compatibility of titanium oxide layer on stainless-steel (SUS316L). The oxide layers with varied thickness were yielded on SUS316L plates by dip-coating of sol-gel solution starting from tetraethyltitanate. The blood compatibility was evaluated in term of platelet adhesion using platelet rich plasma. With increase in the thickness of the oxide layer, the number of adherent platelets decreased rapidly, reached minimum around 150nm. This indicated that the thickness of titanium oxide layer affected platelet adhesion.

Original languageEnglish
Pages (from-to)327-332
Number of pages6
JournalMaterials Research Society Symposium - Proceedings
Volume734
Publication statusPublished - Jun 30 2003
EventPolymer/Metal Interfaces and Defect Mediated Phenomena in Ordered Polymers - Boston, MA, United States
Duration: Dec 2 2002Dec 6 2002

Fingerprint

Stainless Steel
Platelets
platelets
Oxides
compatibility
blood
metal oxides
stainless steels
Blood
Stainless steel
steel
Metals
oxide
Titanium oxides
adhesion
titanium oxides
titanium
Adhesion
oxides
Sol-gels

All Science Journal Classification (ASJC) codes

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

Tsuru, K., Takemoto, S., Yamamoto, T., Hayakawa, S., Osaka, A., & Takashima, S. (2003). Blood compatibility of metal oxide layers on stainless-steel. Materials Research Society Symposium - Proceedings, 734, 327-332.

Blood compatibility of metal oxide layers on stainless-steel. / Tsuru, Kanji; Takemoto, Shinji; Yamamoto, Tatsuhiro; Hayakawa, Satoshi; Osaka, Akiyoshi; Takashima, Seisuke.

In: Materials Research Society Symposium - Proceedings, Vol. 734, 30.06.2003, p. 327-332.

Research output: Contribution to journalConference article

Tsuru, K, Takemoto, S, Yamamoto, T, Hayakawa, S, Osaka, A & Takashima, S 2003, 'Blood compatibility of metal oxide layers on stainless-steel', Materials Research Society Symposium - Proceedings, vol. 734, pp. 327-332.
Tsuru K, Takemoto S, Yamamoto T, Hayakawa S, Osaka A, Takashima S. Blood compatibility of metal oxide layers on stainless-steel. Materials Research Society Symposium - Proceedings. 2003 Jun 30;734:327-332.
Tsuru, Kanji ; Takemoto, Shinji ; Yamamoto, Tatsuhiro ; Hayakawa, Satoshi ; Osaka, Akiyoshi ; Takashima, Seisuke. / Blood compatibility of metal oxide layers on stainless-steel. In: Materials Research Society Symposium - Proceedings. 2003 ; Vol. 734. pp. 327-332.
@article{e5895b897fdb46e2b354f50c8b87646c,
title = "Blood compatibility of metal oxide layers on stainless-steel",
abstract = "We examined blood compatibility of titanium oxide layer on stainless-steel (SUS316L). The oxide layers with varied thickness were yielded on SUS316L plates by dip-coating of sol-gel solution starting from tetraethyltitanate. The blood compatibility was evaluated in term of platelet adhesion using platelet rich plasma. With increase in the thickness of the oxide layer, the number of adherent platelets decreased rapidly, reached minimum around 150nm. This indicated that the thickness of titanium oxide layer affected platelet adhesion.",
author = "Kanji Tsuru and Shinji Takemoto and Tatsuhiro Yamamoto and Satoshi Hayakawa and Akiyoshi Osaka and Seisuke Takashima",
year = "2003",
month = "6",
day = "30",
language = "English",
volume = "734",
pages = "327--332",
journal = "Materials Research Society Symposium - Proceedings",
issn = "0272-9172",
publisher = "Materials Research Society",

}

TY - JOUR

T1 - Blood compatibility of metal oxide layers on stainless-steel

AU - Tsuru, Kanji

AU - Takemoto, Shinji

AU - Yamamoto, Tatsuhiro

AU - Hayakawa, Satoshi

AU - Osaka, Akiyoshi

AU - Takashima, Seisuke

PY - 2003/6/30

Y1 - 2003/6/30

N2 - We examined blood compatibility of titanium oxide layer on stainless-steel (SUS316L). The oxide layers with varied thickness were yielded on SUS316L plates by dip-coating of sol-gel solution starting from tetraethyltitanate. The blood compatibility was evaluated in term of platelet adhesion using platelet rich plasma. With increase in the thickness of the oxide layer, the number of adherent platelets decreased rapidly, reached minimum around 150nm. This indicated that the thickness of titanium oxide layer affected platelet adhesion.

AB - We examined blood compatibility of titanium oxide layer on stainless-steel (SUS316L). The oxide layers with varied thickness were yielded on SUS316L plates by dip-coating of sol-gel solution starting from tetraethyltitanate. The blood compatibility was evaluated in term of platelet adhesion using platelet rich plasma. With increase in the thickness of the oxide layer, the number of adherent platelets decreased rapidly, reached minimum around 150nm. This indicated that the thickness of titanium oxide layer affected platelet adhesion.

UR - http://www.scopus.com/inward/record.url?scp=0038649945&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0038649945&partnerID=8YFLogxK

M3 - Conference article

AN - SCOPUS:0038649945

VL - 734

SP - 327

EP - 332

JO - Materials Research Society Symposium - Proceedings

JF - Materials Research Society Symposium - Proceedings

SN - 0272-9172

ER -