Cathepsin L activity analysis method for evaluation of skin conditions of human

Yusuke Tahara, Akira Date, Teruhiko Makino, Tadamichi Shimizu, Masaki Yamaguchi

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

In order to develop an analysis method of skin conditions for humans, we have been investigating cathepsin L (Cat L) activity derived from stratum corneum as a biomarker. In the present work, an analysis method for a low amount of Cat L activity was demonstrated that was made possible by collecting stratum corneum using a tape stripping, concentrating stratum corneum sample solution and using an inhibitor and a fluorescent substrate of Cat L. Within the range of Cat L activity between 0.003 and 0.04 U/L, the calibration curve for this method showed coefficient with R 2 = 0.98. The Cat L activity ranged between 0.005 and 0.028 U/L in all of the stratum corneum samples in the subjective evaluation. It was indicated that this analysis method had a sufficient range for the analysis of human Cat L activity. The determined coefficient between the Cat L activity and the total protein showed 0.09, which was a comparatively low level. Therefore, it was considered that the Cat L/total protein ratio might be a useful index of the skin condition for humans. Thus, it was indicated that this analysis method might be suitable for an easy analysis of Cat L activity.

Original languageEnglish
Pages (from-to)15-19
Number of pages5
Journalbunseki kagaku
Volume58
Issue number1
DOIs
Publication statusPublished - May 7 2009
Externally publishedYes

Fingerprint

Cathepsin L
Skin
Biomarkers
Tapes
Proteins
Calibration

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

Cathepsin L activity analysis method for evaluation of skin conditions of human. / Tahara, Yusuke; Date, Akira; Makino, Teruhiko; Shimizu, Tadamichi; Yamaguchi, Masaki.

In: bunseki kagaku, Vol. 58, No. 1, 07.05.2009, p. 15-19.

Research output: Contribution to journalArticle

Tahara, Yusuke ; Date, Akira ; Makino, Teruhiko ; Shimizu, Tadamichi ; Yamaguchi, Masaki. / Cathepsin L activity analysis method for evaluation of skin conditions of human. In: bunseki kagaku. 2009 ; Vol. 58, No. 1. pp. 15-19.
@article{92c67781bb4a43a4ac3e80f37a49f2ac,
title = "Cathepsin L activity analysis method for evaluation of skin conditions of human",
abstract = "In order to develop an analysis method of skin conditions for humans, we have been investigating cathepsin L (Cat L) activity derived from stratum corneum as a biomarker. In the present work, an analysis method for a low amount of Cat L activity was demonstrated that was made possible by collecting stratum corneum using a tape stripping, concentrating stratum corneum sample solution and using an inhibitor and a fluorescent substrate of Cat L. Within the range of Cat L activity between 0.003 and 0.04 U/L, the calibration curve for this method showed coefficient with R 2 = 0.98. The Cat L activity ranged between 0.005 and 0.028 U/L in all of the stratum corneum samples in the subjective evaluation. It was indicated that this analysis method had a sufficient range for the analysis of human Cat L activity. The determined coefficient between the Cat L activity and the total protein showed 0.09, which was a comparatively low level. Therefore, it was considered that the Cat L/total protein ratio might be a useful index of the skin condition for humans. Thus, it was indicated that this analysis method might be suitable for an easy analysis of Cat L activity.",
author = "Yusuke Tahara and Akira Date and Teruhiko Makino and Tadamichi Shimizu and Masaki Yamaguchi",
year = "2009",
month = "5",
day = "7",
doi = "10.2116/bunsekikagaku.58.15",
language = "English",
volume = "58",
pages = "15--19",
journal = "Bunseki Kagaku",
issn = "0525-1931",
publisher = "公益社団法人日本分析化学会",
number = "1",

}

TY - JOUR

T1 - Cathepsin L activity analysis method for evaluation of skin conditions of human

AU - Tahara, Yusuke

AU - Date, Akira

AU - Makino, Teruhiko

AU - Shimizu, Tadamichi

AU - Yamaguchi, Masaki

PY - 2009/5/7

Y1 - 2009/5/7

N2 - In order to develop an analysis method of skin conditions for humans, we have been investigating cathepsin L (Cat L) activity derived from stratum corneum as a biomarker. In the present work, an analysis method for a low amount of Cat L activity was demonstrated that was made possible by collecting stratum corneum using a tape stripping, concentrating stratum corneum sample solution and using an inhibitor and a fluorescent substrate of Cat L. Within the range of Cat L activity between 0.003 and 0.04 U/L, the calibration curve for this method showed coefficient with R 2 = 0.98. The Cat L activity ranged between 0.005 and 0.028 U/L in all of the stratum corneum samples in the subjective evaluation. It was indicated that this analysis method had a sufficient range for the analysis of human Cat L activity. The determined coefficient between the Cat L activity and the total protein showed 0.09, which was a comparatively low level. Therefore, it was considered that the Cat L/total protein ratio might be a useful index of the skin condition for humans. Thus, it was indicated that this analysis method might be suitable for an easy analysis of Cat L activity.

AB - In order to develop an analysis method of skin conditions for humans, we have been investigating cathepsin L (Cat L) activity derived from stratum corneum as a biomarker. In the present work, an analysis method for a low amount of Cat L activity was demonstrated that was made possible by collecting stratum corneum using a tape stripping, concentrating stratum corneum sample solution and using an inhibitor and a fluorescent substrate of Cat L. Within the range of Cat L activity between 0.003 and 0.04 U/L, the calibration curve for this method showed coefficient with R 2 = 0.98. The Cat L activity ranged between 0.005 and 0.028 U/L in all of the stratum corneum samples in the subjective evaluation. It was indicated that this analysis method had a sufficient range for the analysis of human Cat L activity. The determined coefficient between the Cat L activity and the total protein showed 0.09, which was a comparatively low level. Therefore, it was considered that the Cat L/total protein ratio might be a useful index of the skin condition for humans. Thus, it was indicated that this analysis method might be suitable for an easy analysis of Cat L activity.

UR - http://www.scopus.com/inward/record.url?scp=65449184216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=65449184216&partnerID=8YFLogxK

U2 - 10.2116/bunsekikagaku.58.15

DO - 10.2116/bunsekikagaku.58.15

M3 - Article

AN - SCOPUS:65449184216

VL - 58

SP - 15

EP - 19

JO - Bunseki Kagaku

JF - Bunseki Kagaku

SN - 0525-1931

IS - 1

ER -