Clinical efficacy of cardiac resynchronization therapy with an implantable defibrillator in a Japanese population - Results of the MIRACLE-ICD outcome measured in Japanese indication (MOMIJI) study -

Shin Ichi Momomura, Hiroyuki Tsutsui, Yoshitaka Sugawara, Makoto Ito, Takeshi Mitsuhashi, Seiji Fukamizu, Mahito Noro, Naoki Matsumoto, Tomoyuki Tejim, Kaoru Sugi

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Background: Cardiac resynchronization therapy (CRT) is effective in reducing morbidity and mortality in systolic heart failure patients with cardiac dyssynchrony as demonstrated in studies with primarily Western populations. Although CRT devices with a defibrillator (CRT-D) became available in Japan since 2006, their efficacy remains uncertain in Japanese patients. In this prospective, multicenter study, the efficacy of CRT-D therapy in an all Japanese population was compared with the study conducted in the US, Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE-ICD). Methods and Results: Ninety-three patients were evaluated according to the subject selection criteria of the MIRACLE-ICD study, and 80 patients were enrolled. Results at baseline and 6-month post-CRT-D implantation were compared in terms of composite clinical response (CCR) and other secondary endpoints. Quality of life (QOL) was assessed with a validated Japanese version of the Minnesota Living with Heart Failure questionnaire. CCR was improved in 55 patients (68.8%), unchanged in 14 (17.5%), and worsened in 11 patients (13.7%) (MIRACLE-ICD general phase: 62.0%, 13.4% and 24.6%, respectively). Non-inferiority was verified by 1-sided test with 10% equivalence margin. QOL score improved significantly (50.0±26.2 vs. 23.6±20.2, P<0.01). Conclusions: The MOMIJI study demonstrated that CRT-D effectiveness as assessed with CCR was non-inferior to the trials conducted outside Japan, thus suggesting that the benefits of CRT-D are similar between Japanese and non-Japanese patients.

Original languageEnglish
Pages (from-to)1911-1919
Number of pages9
JournalCirculation Journal
Volume76
Issue number8
DOIs
Publication statusPublished - 2012
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Fingerprint Dive into the research topics of 'Clinical efficacy of cardiac resynchronization therapy with an implantable defibrillator in a Japanese population - Results of the MIRACLE-ICD outcome measured in Japanese indication (MOMIJI) study -'. Together they form a unique fingerprint.

  • Cite this