Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD

Keita Takahashi, Junji Morishita, Takeshi Hiwasa, Shiro Hatanaka, Shuji Sakai, Noriyuki Hashimoto, Yasuhiko Nakamura, Fukai Toyofuku, Yoshiharu Higashida, Masafumi Ohki

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The goal of this study was to investigate the effect of the different luminance settings of a high-brightness color liquid-crystal display (LCD) on the detectability of a simple grayscale object with low contrast by use of receiver operating characteristic (ROC) analysis. The detectability of a high-brightness color LCD with two maximum-luminance settings (500 and 170 cd/m2) was compared with the detectability of a monochrome LCD (500 cd/m2). The two LCDs used in this study were calibrated to the grayscale standard display function. The average areas under the ROC curve (AUCs) and the standard deviations for all thirteen observers for the 500 cd/m2 color LCD, 500 cd/m2 monochrome LCD, and 170 cd/m2 color LCD were 0.937 ± 0.040, 0.924 ± 0.056, and 0.915 ± 0.068, respectively. There were no statistically significant differences in the average AUCs among the three LCD monitor conditions. On the other hand, the total observation time for the 170 cd/m2 color LCD was significantly shorter than that for the 500 cd/m2 color and monochrome LCDs (p < 0.05). Irrespective of the maximum luminance settings (500 and 170 cd/m2), the color LCD provided a performance comparable to the monochrome LCD for detection of a simple grayscale object with low contrast.

Original languageEnglish
Pages (from-to)178-184
Number of pages7
JournalRadiological physics and technology
Volume3
Issue number2
DOIs
Publication statusPublished - Jul 1 2010

Fingerprint

Liquid Crystals
brightness
Color
liquid crystals
color
luminance
ROC Curve
receivers
curves
Area Under Curve
monitors
standard deviation
Observation

All Science Journal Classification (ASJC) codes

  • Radiation
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Radiology Nuclear Medicine and imaging

Cite this

Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD. / Takahashi, Keita; Morishita, Junji; Hiwasa, Takeshi; Hatanaka, Shiro; Sakai, Shuji; Hashimoto, Noriyuki; Nakamura, Yasuhiko; Toyofuku, Fukai; Higashida, Yoshiharu; Ohki, Masafumi.

In: Radiological physics and technology, Vol. 3, No. 2, 01.07.2010, p. 178-184.

Research output: Contribution to journalArticle

Takahashi, K, Morishita, J, Hiwasa, T, Hatanaka, S, Sakai, S, Hashimoto, N, Nakamura, Y, Toyofuku, F, Higashida, Y & Ohki, M 2010, 'Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD', Radiological physics and technology, vol. 3, no. 2, pp. 178-184. https://doi.org/10.1007/s12194-010-0095-9
Takahashi, Keita ; Morishita, Junji ; Hiwasa, Takeshi ; Hatanaka, Shiro ; Sakai, Shuji ; Hashimoto, Noriyuki ; Nakamura, Yasuhiko ; Toyofuku, Fukai ; Higashida, Yoshiharu ; Ohki, Masafumi. / Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD. In: Radiological physics and technology. 2010 ; Vol. 3, No. 2. pp. 178-184.
@article{15fa489d0a274fa0a734a8fe9210086f,
title = "Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD",
abstract = "The goal of this study was to investigate the effect of the different luminance settings of a high-brightness color liquid-crystal display (LCD) on the detectability of a simple grayscale object with low contrast by use of receiver operating characteristic (ROC) analysis. The detectability of a high-brightness color LCD with two maximum-luminance settings (500 and 170 cd/m2) was compared with the detectability of a monochrome LCD (500 cd/m2). The two LCDs used in this study were calibrated to the grayscale standard display function. The average areas under the ROC curve (AUCs) and the standard deviations for all thirteen observers for the 500 cd/m2 color LCD, 500 cd/m2 monochrome LCD, and 170 cd/m2 color LCD were 0.937 ± 0.040, 0.924 ± 0.056, and 0.915 ± 0.068, respectively. There were no statistically significant differences in the average AUCs among the three LCD monitor conditions. On the other hand, the total observation time for the 170 cd/m2 color LCD was significantly shorter than that for the 500 cd/m2 color and monochrome LCDs (p < 0.05). Irrespective of the maximum luminance settings (500 and 170 cd/m2), the color LCD provided a performance comparable to the monochrome LCD for detection of a simple grayscale object with low contrast.",
author = "Keita Takahashi and Junji Morishita and Takeshi Hiwasa and Shiro Hatanaka and Shuji Sakai and Noriyuki Hashimoto and Yasuhiko Nakamura and Fukai Toyofuku and Yoshiharu Higashida and Masafumi Ohki",
year = "2010",
month = "7",
day = "1",
doi = "10.1007/s12194-010-0095-9",
language = "English",
volume = "3",
pages = "178--184",
journal = "Radiological Physics and Technology",
issn = "1865-0333",
publisher = "Springer Japan",
number = "2",

}

TY - JOUR

T1 - Comparison of detectability of a simple object with low contrast displayed on a high-brightness color LCD and a monochrome LCD

AU - Takahashi, Keita

AU - Morishita, Junji

AU - Hiwasa, Takeshi

AU - Hatanaka, Shiro

AU - Sakai, Shuji

AU - Hashimoto, Noriyuki

AU - Nakamura, Yasuhiko

AU - Toyofuku, Fukai

AU - Higashida, Yoshiharu

AU - Ohki, Masafumi

PY - 2010/7/1

Y1 - 2010/7/1

N2 - The goal of this study was to investigate the effect of the different luminance settings of a high-brightness color liquid-crystal display (LCD) on the detectability of a simple grayscale object with low contrast by use of receiver operating characteristic (ROC) analysis. The detectability of a high-brightness color LCD with two maximum-luminance settings (500 and 170 cd/m2) was compared with the detectability of a monochrome LCD (500 cd/m2). The two LCDs used in this study were calibrated to the grayscale standard display function. The average areas under the ROC curve (AUCs) and the standard deviations for all thirteen observers for the 500 cd/m2 color LCD, 500 cd/m2 monochrome LCD, and 170 cd/m2 color LCD were 0.937 ± 0.040, 0.924 ± 0.056, and 0.915 ± 0.068, respectively. There were no statistically significant differences in the average AUCs among the three LCD monitor conditions. On the other hand, the total observation time for the 170 cd/m2 color LCD was significantly shorter than that for the 500 cd/m2 color and monochrome LCDs (p < 0.05). Irrespective of the maximum luminance settings (500 and 170 cd/m2), the color LCD provided a performance comparable to the monochrome LCD for detection of a simple grayscale object with low contrast.

AB - The goal of this study was to investigate the effect of the different luminance settings of a high-brightness color liquid-crystal display (LCD) on the detectability of a simple grayscale object with low contrast by use of receiver operating characteristic (ROC) analysis. The detectability of a high-brightness color LCD with two maximum-luminance settings (500 and 170 cd/m2) was compared with the detectability of a monochrome LCD (500 cd/m2). The two LCDs used in this study were calibrated to the grayscale standard display function. The average areas under the ROC curve (AUCs) and the standard deviations for all thirteen observers for the 500 cd/m2 color LCD, 500 cd/m2 monochrome LCD, and 170 cd/m2 color LCD were 0.937 ± 0.040, 0.924 ± 0.056, and 0.915 ± 0.068, respectively. There were no statistically significant differences in the average AUCs among the three LCD monitor conditions. On the other hand, the total observation time for the 170 cd/m2 color LCD was significantly shorter than that for the 500 cd/m2 color and monochrome LCDs (p < 0.05). Irrespective of the maximum luminance settings (500 and 170 cd/m2), the color LCD provided a performance comparable to the monochrome LCD for detection of a simple grayscale object with low contrast.

UR - http://www.scopus.com/inward/record.url?scp=77955517466&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77955517466&partnerID=8YFLogxK

U2 - 10.1007/s12194-010-0095-9

DO - 10.1007/s12194-010-0095-9

M3 - Article

C2 - 20821093

AN - SCOPUS:77955517466

VL - 3

SP - 178

EP - 184

JO - Radiological Physics and Technology

JF - Radiological Physics and Technology

SN - 1865-0333

IS - 2

ER -