Control strategy of developed mechanical actuator in measuring hole surface parameter

Md Hazrat Ali, Akio Katsuki, Takao Sajima, Hiroshi Murakami, Syuhei Kurokawa

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This paper presents the control strategy of a new type of mechanical actuator used to help in measuring hole surface parameter. The actuator can carry up to a load of 26 kg during measurement. Often, the measurement unit’s attitude is misaligned due to the force acting on it. Actuator is used in order to control the misalignment of such system during measurement. In this research, the complete measurement system consists of a servo motor, a laser diode, a laser interferometer, an optical system, as well as an integrated computer system. The main purpose of this research is to develop the new type of actuator which can control the attitude (position and inclination) of a measurement probe. The experimental results show that it is possible to carry mechanically the loads up to 26 kg of the measurement probe during measurement of deep surface. In this paper, the developed actuator’s control strategy has been discussed widely in order to measure the surface parameter successfully.

Original languageEnglish
Pages (from-to)777-786
Number of pages10
JournalInternational Journal of Advanced Manufacturing Technology
Volume84
Issue number5-8
DOIs
Publication statusPublished - May 1 2016

Fingerprint

Mechanical actuators
Actuators
Units of measurement
Optical systems
Interferometers
Semiconductor lasers
Computer systems
Lasers

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Software
  • Mechanical Engineering
  • Computer Science Applications
  • Industrial and Manufacturing Engineering

Cite this

Control strategy of developed mechanical actuator in measuring hole surface parameter. / Ali, Md Hazrat; Katsuki, Akio; Sajima, Takao; Murakami, Hiroshi; Kurokawa, Syuhei.

In: International Journal of Advanced Manufacturing Technology, Vol. 84, No. 5-8, 01.05.2016, p. 777-786.

Research output: Contribution to journalArticle

@article{8830a28d355e41c7b7431bb360db66ca,
title = "Control strategy of developed mechanical actuator in measuring hole surface parameter",
abstract = "This paper presents the control strategy of a new type of mechanical actuator used to help in measuring hole surface parameter. The actuator can carry up to a load of 26 kg during measurement. Often, the measurement unit’s attitude is misaligned due to the force acting on it. Actuator is used in order to control the misalignment of such system during measurement. In this research, the complete measurement system consists of a servo motor, a laser diode, a laser interferometer, an optical system, as well as an integrated computer system. The main purpose of this research is to develop the new type of actuator which can control the attitude (position and inclination) of a measurement probe. The experimental results show that it is possible to carry mechanically the loads up to 26 kg of the measurement probe during measurement of deep surface. In this paper, the developed actuator’s control strategy has been discussed widely in order to measure the surface parameter successfully.",
author = "Ali, {Md Hazrat} and Akio Katsuki and Takao Sajima and Hiroshi Murakami and Syuhei Kurokawa",
year = "2016",
month = "5",
day = "1",
doi = "10.1007/s00170-013-5420-0",
language = "English",
volume = "84",
pages = "777--786",
journal = "International Journal of Advanced Manufacturing Technology",
issn = "0268-3768",
publisher = "Springer London",
number = "5-8",

}

TY - JOUR

T1 - Control strategy of developed mechanical actuator in measuring hole surface parameter

AU - Ali, Md Hazrat

AU - Katsuki, Akio

AU - Sajima, Takao

AU - Murakami, Hiroshi

AU - Kurokawa, Syuhei

PY - 2016/5/1

Y1 - 2016/5/1

N2 - This paper presents the control strategy of a new type of mechanical actuator used to help in measuring hole surface parameter. The actuator can carry up to a load of 26 kg during measurement. Often, the measurement unit’s attitude is misaligned due to the force acting on it. Actuator is used in order to control the misalignment of such system during measurement. In this research, the complete measurement system consists of a servo motor, a laser diode, a laser interferometer, an optical system, as well as an integrated computer system. The main purpose of this research is to develop the new type of actuator which can control the attitude (position and inclination) of a measurement probe. The experimental results show that it is possible to carry mechanically the loads up to 26 kg of the measurement probe during measurement of deep surface. In this paper, the developed actuator’s control strategy has been discussed widely in order to measure the surface parameter successfully.

AB - This paper presents the control strategy of a new type of mechanical actuator used to help in measuring hole surface parameter. The actuator can carry up to a load of 26 kg during measurement. Often, the measurement unit’s attitude is misaligned due to the force acting on it. Actuator is used in order to control the misalignment of such system during measurement. In this research, the complete measurement system consists of a servo motor, a laser diode, a laser interferometer, an optical system, as well as an integrated computer system. The main purpose of this research is to develop the new type of actuator which can control the attitude (position and inclination) of a measurement probe. The experimental results show that it is possible to carry mechanically the loads up to 26 kg of the measurement probe during measurement of deep surface. In this paper, the developed actuator’s control strategy has been discussed widely in order to measure the surface parameter successfully.

UR - http://www.scopus.com/inward/record.url?scp=84887305686&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84887305686&partnerID=8YFLogxK

U2 - 10.1007/s00170-013-5420-0

DO - 10.1007/s00170-013-5420-0

M3 - Article

VL - 84

SP - 777

EP - 786

JO - International Journal of Advanced Manufacturing Technology

JF - International Journal of Advanced Manufacturing Technology

SN - 0268-3768

IS - 5-8