Coulometric detection of components in liquid plugs by microfabricated flow channel and electrode structures

Fumihiro Sassa, Hind Laghzali, Junji Fukuda, Hiroaki Suzuki

Research output: Contribution to journalArticle

35 Citations (Scopus)

Abstract

Coulometry has been demonstrated to be effective for determining the analyte in a liquid plug on the nanoliter-scale confined in a flow channel. A plug prepared in a rhombus structure of an auxiliary flow channel was placed on a thin-film three-electrode system, and hydrogen peroxide was detected as a model analyte. Under a fixed potential, the current decayed rapidly, particularly in shallow flow channels, thus making reproducible amperometric detection difficult. On the other hand, the increasing charge during coulometry facilitated the measurements. A constricted flow channel structure with an array of platinum strips for the working electrode was effective at efficiently consuming the analyte to improve the sensitivity and lower the detection limit. Compared to the case of a single short working electrode with the same area, a 4-fold increase in sensitivity was observed for the best combination of flow channel height and interstrip distance. With an increase in the generated current while maintaining the background at a low level, the detection limit was lowered from 1.3 μM to 410 nM using working electrodes with the same area. Furthermore, the processing of solutions containing l-glutamate or l-glutamate oxidase and the detection of l-glutamate were demonstrated.

Original languageEnglish
Pages (from-to)8725-8732
Number of pages8
JournalAnalytical chemistry
Volume82
Issue number20
DOIs
Publication statusPublished - Oct 15 2010

Fingerprint

Channel flow
Electrodes
Coulometers
Liquids
Glutamic Acid
Platinum
Hydrogen Peroxide
Oxidoreductases
Thin films
Processing

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

Coulometric detection of components in liquid plugs by microfabricated flow channel and electrode structures. / Sassa, Fumihiro; Laghzali, Hind; Fukuda, Junji; Suzuki, Hiroaki.

In: Analytical chemistry, Vol. 82, No. 20, 15.10.2010, p. 8725-8732.

Research output: Contribution to journalArticle

Sassa, Fumihiro ; Laghzali, Hind ; Fukuda, Junji ; Suzuki, Hiroaki. / Coulometric detection of components in liquid plugs by microfabricated flow channel and electrode structures. In: Analytical chemistry. 2010 ; Vol. 82, No. 20. pp. 8725-8732.
@article{a77f721458fc4964b478d57acedef6af,
title = "Coulometric detection of components in liquid plugs by microfabricated flow channel and electrode structures",
abstract = "Coulometry has been demonstrated to be effective for determining the analyte in a liquid plug on the nanoliter-scale confined in a flow channel. A plug prepared in a rhombus structure of an auxiliary flow channel was placed on a thin-film three-electrode system, and hydrogen peroxide was detected as a model analyte. Under a fixed potential, the current decayed rapidly, particularly in shallow flow channels, thus making reproducible amperometric detection difficult. On the other hand, the increasing charge during coulometry facilitated the measurements. A constricted flow channel structure with an array of platinum strips for the working electrode was effective at efficiently consuming the analyte to improve the sensitivity and lower the detection limit. Compared to the case of a single short working electrode with the same area, a 4-fold increase in sensitivity was observed for the best combination of flow channel height and interstrip distance. With an increase in the generated current while maintaining the background at a low level, the detection limit was lowered from 1.3 μM to 410 nM using working electrodes with the same area. Furthermore, the processing of solutions containing l-glutamate or l-glutamate oxidase and the detection of l-glutamate were demonstrated.",
author = "Fumihiro Sassa and Hind Laghzali and Junji Fukuda and Hiroaki Suzuki",
year = "2010",
month = "10",
day = "15",
doi = "10.1021/ac102289a",
language = "English",
volume = "82",
pages = "8725--8732",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "20",

}

TY - JOUR

T1 - Coulometric detection of components in liquid plugs by microfabricated flow channel and electrode structures

AU - Sassa, Fumihiro

AU - Laghzali, Hind

AU - Fukuda, Junji

AU - Suzuki, Hiroaki

PY - 2010/10/15

Y1 - 2010/10/15

N2 - Coulometry has been demonstrated to be effective for determining the analyte in a liquid plug on the nanoliter-scale confined in a flow channel. A plug prepared in a rhombus structure of an auxiliary flow channel was placed on a thin-film three-electrode system, and hydrogen peroxide was detected as a model analyte. Under a fixed potential, the current decayed rapidly, particularly in shallow flow channels, thus making reproducible amperometric detection difficult. On the other hand, the increasing charge during coulometry facilitated the measurements. A constricted flow channel structure with an array of platinum strips for the working electrode was effective at efficiently consuming the analyte to improve the sensitivity and lower the detection limit. Compared to the case of a single short working electrode with the same area, a 4-fold increase in sensitivity was observed for the best combination of flow channel height and interstrip distance. With an increase in the generated current while maintaining the background at a low level, the detection limit was lowered from 1.3 μM to 410 nM using working electrodes with the same area. Furthermore, the processing of solutions containing l-glutamate or l-glutamate oxidase and the detection of l-glutamate were demonstrated.

AB - Coulometry has been demonstrated to be effective for determining the analyte in a liquid plug on the nanoliter-scale confined in a flow channel. A plug prepared in a rhombus structure of an auxiliary flow channel was placed on a thin-film three-electrode system, and hydrogen peroxide was detected as a model analyte. Under a fixed potential, the current decayed rapidly, particularly in shallow flow channels, thus making reproducible amperometric detection difficult. On the other hand, the increasing charge during coulometry facilitated the measurements. A constricted flow channel structure with an array of platinum strips for the working electrode was effective at efficiently consuming the analyte to improve the sensitivity and lower the detection limit. Compared to the case of a single short working electrode with the same area, a 4-fold increase in sensitivity was observed for the best combination of flow channel height and interstrip distance. With an increase in the generated current while maintaining the background at a low level, the detection limit was lowered from 1.3 μM to 410 nM using working electrodes with the same area. Furthermore, the processing of solutions containing l-glutamate or l-glutamate oxidase and the detection of l-glutamate were demonstrated.

UR - http://www.scopus.com/inward/record.url?scp=77958036043&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77958036043&partnerID=8YFLogxK

U2 - 10.1021/ac102289a

DO - 10.1021/ac102289a

M3 - Article

C2 - 20857923

AN - SCOPUS:77958036043

VL - 82

SP - 8725

EP - 8732

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 20

ER -