Cryogenic cooling system for HTS cable

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

Original languageEnglish
Pages (from-to)1-8
Number of pages8
JournalProgress in Superconductivity and Cryogenics (PSAC)
Volume19
Issue number2
DOIs
Publication statusPublished - Jun 1 2017

Fingerprint

Superconducting cables
Cooling systems
Cryogenics
Temperature
Cryogenic equipment
Superconducting fault current limiters
Refrigerators
Liquid nitrogen
Cables
Thermodynamic properties

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Cryogenic cooling system for HTS cable. / Yoshida, Shigeru.

In: Progress in Superconductivity and Cryogenics (PSAC), Vol. 19, No. 2, 01.06.2017, p. 1-8.

Research output: Contribution to journalArticle

@article{616a9211daed4dffbfc238a950c2534f,
title = "Cryogenic cooling system for HTS cable",
abstract = "Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.",
author = "Shigeru Yoshida",
year = "2017",
month = "6",
day = "1",
doi = "10.9714/psac.2017.19.2.001",
language = "English",
volume = "19",
pages = "1--8",
journal = "Progress in Superconductivity and Cryogenics (PSAC)",
issn = "1229-3008",
publisher = "Korea Institute of Applied Superconductivity and Cryogenics",
number = "2",

}

TY - JOUR

T1 - Cryogenic cooling system for HTS cable

AU - Yoshida, Shigeru

PY - 2017/6/1

Y1 - 2017/6/1

N2 - Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

AB - Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

UR - http://www.scopus.com/inward/record.url?scp=85021807824&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021807824&partnerID=8YFLogxK

U2 - 10.9714/psac.2017.19.2.001

DO - 10.9714/psac.2017.19.2.001

M3 - Article

VL - 19

SP - 1

EP - 8

JO - Progress in Superconductivity and Cryogenics (PSAC)

JF - Progress in Superconductivity and Cryogenics (PSAC)

SN - 1229-3008

IS - 2

ER -