Design and electronics commissioning of the physics prototype of a si-w electromagnetic calorimeter for the international linear collider

J. Repond, J. Yu, M. Hawkes, Y. Mikami, O. Miller, K. Watson, A. Wilson, G. Mavromanolakis, A. Thomson, R. Ward, W. Yan, F. Badaud, D. Boumediene, C. Crloganu, R. Cornat, P. Gay, Gris Ph Gris, S. Manen, F. Morisseau, L. RoyerC. Blazey, D. Chakraborty, A. Dyshkant, K. Francis, D. Hedin, G. Lima, V. Zutshi, Hostachy J-Y Hostachy, L. Morin, E. Garutti, V. Korbel, F. Sefkow, M. Groll, G. Kim, Kim D-W Kim, K. Lee, S. Lee, K. Kawagoe, Y. Tamura, A. Bowerman, D. Dauncey, A. M. Magnan, C. Noronha, H. Yilmaz, O. Zorba, V. Bartsch, M. Butterworth, M. Postranecky, M. Warren, M. Wing, M. Faucci Giannelli, G. Green, F. Salvatore, T. Wu, D. Bailey, J. Barlow, M. Kelly, S. Snow, J. Thompson, M. Danilov, V. Kochetkov, N. Baranova, P. Ermolov, D. Karmanov, M. Korolev, M. Merkin, A. Voronin, B. Bouquet, S. Callier, F. Dulucq, J. Fleury, H. Li, G. Martin-Chassard, F. Richard, Ch De La Taille, R. Poeschl, L. Raux, M. Ruan, N. Seguin-Moreau, F. Wicek, Z. Zhang, M. Anduze, V. Boudry, J. C. Brient, C. Clerc, G. Gaycken, C. Jauffret, A. Karar, P. Mora De Freitas, G. Musat, M. Reinhard, A. Rougé, L. Sanchez, Vanel J-Ch Vanel, H. Videau, J. Zacek, J. Cvach, P. Gallus, M. Havranek, M. Janata, M. Marcisovsky, I. Polak, J. Popule, L. Tomasek, M. Tomasek, P. Ruzicka, P. Sicho, J. Smolik, V. Vrba, J. Zalesak, Arestov Yu Arestov, A. Baird, N. Halsall, W. Nam, H. Park, J. Yang

Research output: Contribution to journalArticle

80 Citations (Scopus)

Abstract

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A "physics prototype" has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18×18 cm2 and a pad size of 1×1 cm 2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.630.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.

Original languageEnglish
Article numberP08001
JournalJournal of Instrumentation
Volume3
Issue number8
DOIs
Publication statusPublished - Dec 1 2008
Externally publishedYes

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Mathematical Physics
  • Instrumentation

Cite this