In this study, high-performance monitoring system for blood sugar was developed by using microchip electrophoresis with a plastic chip. A combination of a reductive amination as sugar labeling and sugar-borate complex formation realized highly selective detection of blood sugar even in a blood sample. This paper demonstrates that this system enables us to determine blood sugar with high sensitivity and high accuracy, and it will be applicable to clinical diagnosis.

Original languageEnglish
Pages813-815
Number of pages3
Publication statusPublished - Jan 1 2006
Externally publishedYes
Event10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006 - Tokyo, Japan
Duration: Nov 5 2006Nov 9 2006

Other

Other10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006
CountryJapan
CityTokyo
Period11/5/0611/9/06

Fingerprint

Electrophoresis
Sugars
Blood Glucose
Blood
Amination
Borates
Labeling
Plastics
Monitoring

All Science Journal Classification (ASJC) codes

  • Chemical Engineering (miscellaneous)
  • Bioengineering

Cite this

Maeda, E., Kataoka, M., Shinohara, Y., Kaji, N., Tokeshi, M., & Baba, Y. (2006). Determination of blood sugar using microchip electrophoresis. 813-815. Paper presented at 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006, Tokyo, Japan.

Determination of blood sugar using microchip electrophoresis. / Maeda, Eiki; Kataoka, Masatoshi; Shinohara, Yasuo; Kaji, Noritada; Tokeshi, Manabu; Baba, Yoshinobu.

2006. 813-815 Paper presented at 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006, Tokyo, Japan.

Research output: Contribution to conferencePaper

Maeda, E, Kataoka, M, Shinohara, Y, Kaji, N, Tokeshi, M & Baba, Y 2006, 'Determination of blood sugar using microchip electrophoresis' Paper presented at 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006, Tokyo, Japan, 11/5/06 - 11/9/06, pp. 813-815.
Maeda E, Kataoka M, Shinohara Y, Kaji N, Tokeshi M, Baba Y. Determination of blood sugar using microchip electrophoresis. 2006. Paper presented at 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006, Tokyo, Japan.
Maeda, Eiki ; Kataoka, Masatoshi ; Shinohara, Yasuo ; Kaji, Noritada ; Tokeshi, Manabu ; Baba, Yoshinobu. / Determination of blood sugar using microchip electrophoresis. Paper presented at 10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006, Tokyo, Japan.3 p.
@conference{f6f0fc12c58545d9892dc157bf3653bf,
title = "Determination of blood sugar using microchip electrophoresis",
abstract = "In this study, high-performance monitoring system for blood sugar was developed by using microchip electrophoresis with a plastic chip. A combination of a reductive amination as sugar labeling and sugar-borate complex formation realized highly selective detection of blood sugar even in a blood sample. This paper demonstrates that this system enables us to determine blood sugar with high sensitivity and high accuracy, and it will be applicable to clinical diagnosis.",
author = "Eiki Maeda and Masatoshi Kataoka and Yasuo Shinohara and Noritada Kaji and Manabu Tokeshi and Yoshinobu Baba",
year = "2006",
month = "1",
day = "1",
language = "English",
pages = "813--815",
note = "10th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2006 ; Conference date: 05-11-2006 Through 09-11-2006",

}

TY - CONF

T1 - Determination of blood sugar using microchip electrophoresis

AU - Maeda, Eiki

AU - Kataoka, Masatoshi

AU - Shinohara, Yasuo

AU - Kaji, Noritada

AU - Tokeshi, Manabu

AU - Baba, Yoshinobu

PY - 2006/1/1

Y1 - 2006/1/1

N2 - In this study, high-performance monitoring system for blood sugar was developed by using microchip electrophoresis with a plastic chip. A combination of a reductive amination as sugar labeling and sugar-borate complex formation realized highly selective detection of blood sugar even in a blood sample. This paper demonstrates that this system enables us to determine blood sugar with high sensitivity and high accuracy, and it will be applicable to clinical diagnosis.

AB - In this study, high-performance monitoring system for blood sugar was developed by using microchip electrophoresis with a plastic chip. A combination of a reductive amination as sugar labeling and sugar-borate complex formation realized highly selective detection of blood sugar even in a blood sample. This paper demonstrates that this system enables us to determine blood sugar with high sensitivity and high accuracy, and it will be applicable to clinical diagnosis.

UR - http://www.scopus.com/inward/record.url?scp=84902530715&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84902530715&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:84902530715

SP - 813

EP - 815

ER -