Determination of rare earth impurities in ultrapure europium oxide by inductively-coupled plasma mass spectrometry

Shu Xiu Zhang, Shinichiro Murachi, Totaro Imasaka, Midori Watanabe

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

Trace quantities of rare earth elements (REEs) in ultrapure europium oxide (Eu2O3) are measured by inductively coupled plasma mass spectrometry (ICP-MS). The signal intensity of REE decreases with increasing concentration of europium oxide. Then, the internal standard method is examined to minimize this signal suppression. Four internal standards, cadmium (111Cd+) and indium (115In+), and thallium (205TI+) and bismuth (209Bi+) are investigated, since their mass numbers are close to those of lighter (89Y+-157Gd+) and heavier (159Tb+-175Lu+) REEs, respectively. The use of internal standards o Cd and In suppress interference for lighter REEs, and Tl and Bi for heavier REEs. These results imply the interference concerned with a mass-related space charge effect. In trace analysis of REE impurities in ultrapure Eu2O3, In and Tl are suggested to be used as internal standards for lighter and heavier REEs, respectively, due to the recoveries close to 100%. Lighter REE oxide ions occurring in a plasma generally interfere with the determination of heavier REEs. However, almost all REEs are determined correctly even at ultratrace levels by a proper selection of isotope. Unfortunately, polyatomic ions from the europium oxide such as 153EuO+ and 153Eu18OH+ ions seriously interfere with the determination of 169Tm+ and 172Yb+. These interferences are reduced by using ion chromatography (IC) combined with ICP-MS detection.

Original languageEnglish
Pages (from-to)193-201
Number of pages9
JournalAnalytica Chimica Acta
Volume314
Issue number3
DOIs
Publication statusPublished - Oct 20 1995

Fingerprint

Europium
Inductively coupled plasma mass spectrometry
europium
Rare earth elements
Oxides
Rare earths
Mass Spectrometry
rare earth element
mass spectrometry
oxide
Impurities
Ions
plasma
Bismuth
Indium
Thallium
Cadmium
Isotopes
Chromatography
ion

All Science Journal Classification (ASJC) codes

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Determination of rare earth impurities in ultrapure europium oxide by inductively-coupled plasma mass spectrometry. / Zhang, Shu Xiu; Murachi, Shinichiro; Imasaka, Totaro; Watanabe, Midori.

In: Analytica Chimica Acta, Vol. 314, No. 3, 20.10.1995, p. 193-201.

Research output: Contribution to journalArticle

@article{3d3161fc098949618d72ed6d91427f6f,
title = "Determination of rare earth impurities in ultrapure europium oxide by inductively-coupled plasma mass spectrometry",
abstract = "Trace quantities of rare earth elements (REEs) in ultrapure europium oxide (Eu2O3) are measured by inductively coupled plasma mass spectrometry (ICP-MS). The signal intensity of REE decreases with increasing concentration of europium oxide. Then, the internal standard method is examined to minimize this signal suppression. Four internal standards, cadmium (111Cd+) and indium (115In+), and thallium (205TI+) and bismuth (209Bi+) are investigated, since their mass numbers are close to those of lighter (89Y+-157Gd+) and heavier (159Tb+-175Lu+) REEs, respectively. The use of internal standards o Cd and In suppress interference for lighter REEs, and Tl and Bi for heavier REEs. These results imply the interference concerned with a mass-related space charge effect. In trace analysis of REE impurities in ultrapure Eu2O3, In and Tl are suggested to be used as internal standards for lighter and heavier REEs, respectively, due to the recoveries close to 100{\%}. Lighter REE oxide ions occurring in a plasma generally interfere with the determination of heavier REEs. However, almost all REEs are determined correctly even at ultratrace levels by a proper selection of isotope. Unfortunately, polyatomic ions from the europium oxide such as 153EuO+ and 153Eu18OH+ ions seriously interfere with the determination of 169Tm+ and 172Yb+. These interferences are reduced by using ion chromatography (IC) combined with ICP-MS detection.",
author = "Zhang, {Shu Xiu} and Shinichiro Murachi and Totaro Imasaka and Midori Watanabe",
year = "1995",
month = "10",
day = "20",
doi = "10.1016/0003-2670(95)00273-3",
language = "English",
volume = "314",
pages = "193--201",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "3",

}

TY - JOUR

T1 - Determination of rare earth impurities in ultrapure europium oxide by inductively-coupled plasma mass spectrometry

AU - Zhang, Shu Xiu

AU - Murachi, Shinichiro

AU - Imasaka, Totaro

AU - Watanabe, Midori

PY - 1995/10/20

Y1 - 1995/10/20

N2 - Trace quantities of rare earth elements (REEs) in ultrapure europium oxide (Eu2O3) are measured by inductively coupled plasma mass spectrometry (ICP-MS). The signal intensity of REE decreases with increasing concentration of europium oxide. Then, the internal standard method is examined to minimize this signal suppression. Four internal standards, cadmium (111Cd+) and indium (115In+), and thallium (205TI+) and bismuth (209Bi+) are investigated, since their mass numbers are close to those of lighter (89Y+-157Gd+) and heavier (159Tb+-175Lu+) REEs, respectively. The use of internal standards o Cd and In suppress interference for lighter REEs, and Tl and Bi for heavier REEs. These results imply the interference concerned with a mass-related space charge effect. In trace analysis of REE impurities in ultrapure Eu2O3, In and Tl are suggested to be used as internal standards for lighter and heavier REEs, respectively, due to the recoveries close to 100%. Lighter REE oxide ions occurring in a plasma generally interfere with the determination of heavier REEs. However, almost all REEs are determined correctly even at ultratrace levels by a proper selection of isotope. Unfortunately, polyatomic ions from the europium oxide such as 153EuO+ and 153Eu18OH+ ions seriously interfere with the determination of 169Tm+ and 172Yb+. These interferences are reduced by using ion chromatography (IC) combined with ICP-MS detection.

AB - Trace quantities of rare earth elements (REEs) in ultrapure europium oxide (Eu2O3) are measured by inductively coupled plasma mass spectrometry (ICP-MS). The signal intensity of REE decreases with increasing concentration of europium oxide. Then, the internal standard method is examined to minimize this signal suppression. Four internal standards, cadmium (111Cd+) and indium (115In+), and thallium (205TI+) and bismuth (209Bi+) are investigated, since their mass numbers are close to those of lighter (89Y+-157Gd+) and heavier (159Tb+-175Lu+) REEs, respectively. The use of internal standards o Cd and In suppress interference for lighter REEs, and Tl and Bi for heavier REEs. These results imply the interference concerned with a mass-related space charge effect. In trace analysis of REE impurities in ultrapure Eu2O3, In and Tl are suggested to be used as internal standards for lighter and heavier REEs, respectively, due to the recoveries close to 100%. Lighter REE oxide ions occurring in a plasma generally interfere with the determination of heavier REEs. However, almost all REEs are determined correctly even at ultratrace levels by a proper selection of isotope. Unfortunately, polyatomic ions from the europium oxide such as 153EuO+ and 153Eu18OH+ ions seriously interfere with the determination of 169Tm+ and 172Yb+. These interferences are reduced by using ion chromatography (IC) combined with ICP-MS detection.

UR - http://www.scopus.com/inward/record.url?scp=0028834581&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028834581&partnerID=8YFLogxK

U2 - 10.1016/0003-2670(95)00273-3

DO - 10.1016/0003-2670(95)00273-3

M3 - Article

AN - SCOPUS:0028834581

VL - 314

SP - 193

EP - 201

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 3

ER -