Development and evaluation of a visual aid using see-through display for patients with retinitis pigmentosa

Yasuhiro Ikeda, Eiji Suzuki, Takashi Kuramata, Tetsuo Kozaki, Tetsuya Koyama, Yuji Kato, yusuke murakami, Hiroshi Enaida, Tatsuro Ishibashi

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Purpose: Patients in the early stage of retinitis pigmentosa (RP) suffer from night blindness and, therefore, have mobility problems at night. To assist such patients with walking in the dark, we developed a wearable visual aid utilizing a see-through display upon which assistive images from a high-sensitivity video camera are superimposed. We evaluated the efficacy of our new visual aid for RP patients. Methods: The device is equipped with a camera with a minimum illuminance of 0.08 lux and a view angle of 53° × 40°. The experiment was conducted in a room with dimmed light (illuminance level 0.2–1.2 lux). Eight subjects with RP were instructed to arrive at a goal 16 m away from the starting point, both with and without the device, passing through four 1.5-m-wide gates consisting of pairs of black square carpet pieces, white poles, red and white traffic cones and cardboard boxes with and without the device in a darkened room. Three gates, except for the boxes, which were nearest the goal, were randomly arranged along the x-axis at each trial. The number of trial failures and the time required to walk the course were assessed as outcomes. Results: Seven of the 8 subjects could walk with the aid of the device without any failure. With the device, the number of trial failures significantly decreased in number (p < 0.05) in all subjects. Conclusions: This device enabled the subjects to see objects that could not be recognized by the unaided eye. Our visual aid effectively assisted RP patients with night blindness.

Original languageEnglish
Pages (from-to)43-47
Number of pages5
JournalJapanese Journal of Ophthalmology
Volume59
Issue number1
DOIs
Publication statusPublished - Jan 1 2015

Fingerprint

Audiovisual Aids
Retinitis Pigmentosa
Equipment and Supplies
Night Blindness
Walking
Light

All Science Journal Classification (ASJC) codes

  • Ophthalmology

Cite this

Development and evaluation of a visual aid using see-through display for patients with retinitis pigmentosa. / Ikeda, Yasuhiro; Suzuki, Eiji; Kuramata, Takashi; Kozaki, Tetsuo; Koyama, Tetsuya; Kato, Yuji; murakami, yusuke; Enaida, Hiroshi; Ishibashi, Tatsuro.

In: Japanese Journal of Ophthalmology, Vol. 59, No. 1, 01.01.2015, p. 43-47.

Research output: Contribution to journalArticle

Ikeda, Yasuhiro ; Suzuki, Eiji ; Kuramata, Takashi ; Kozaki, Tetsuo ; Koyama, Tetsuya ; Kato, Yuji ; murakami, yusuke ; Enaida, Hiroshi ; Ishibashi, Tatsuro. / Development and evaluation of a visual aid using see-through display for patients with retinitis pigmentosa. In: Japanese Journal of Ophthalmology. 2015 ; Vol. 59, No. 1. pp. 43-47.
@article{41cade0e0c184f0f97e1e5e1c750ad6b,
title = "Development and evaluation of a visual aid using see-through display for patients with retinitis pigmentosa",
abstract = "Purpose: Patients in the early stage of retinitis pigmentosa (RP) suffer from night blindness and, therefore, have mobility problems at night. To assist such patients with walking in the dark, we developed a wearable visual aid utilizing a see-through display upon which assistive images from a high-sensitivity video camera are superimposed. We evaluated the efficacy of our new visual aid for RP patients. Methods: The device is equipped with a camera with a minimum illuminance of 0.08 lux and a view angle of 53° × 40°. The experiment was conducted in a room with dimmed light (illuminance level 0.2–1.2 lux). Eight subjects with RP were instructed to arrive at a goal 16 m away from the starting point, both with and without the device, passing through four 1.5-m-wide gates consisting of pairs of black square carpet pieces, white poles, red and white traffic cones and cardboard boxes with and without the device in a darkened room. Three gates, except for the boxes, which were nearest the goal, were randomly arranged along the x-axis at each trial. The number of trial failures and the time required to walk the course were assessed as outcomes. Results: Seven of the 8 subjects could walk with the aid of the device without any failure. With the device, the number of trial failures significantly decreased in number (p < 0.05) in all subjects. Conclusions: This device enabled the subjects to see objects that could not be recognized by the unaided eye. Our visual aid effectively assisted RP patients with night blindness.",
author = "Yasuhiro Ikeda and Eiji Suzuki and Takashi Kuramata and Tetsuo Kozaki and Tetsuya Koyama and Yuji Kato and yusuke murakami and Hiroshi Enaida and Tatsuro Ishibashi",
year = "2015",
month = "1",
day = "1",
doi = "10.1007/s10384-014-0354-0",
language = "English",
volume = "59",
pages = "43--47",
journal = "Japanese Journal of Ophthalmology",
issn = "0021-5155",
publisher = "Springer Japan",
number = "1",

}

TY - JOUR

T1 - Development and evaluation of a visual aid using see-through display for patients with retinitis pigmentosa

AU - Ikeda, Yasuhiro

AU - Suzuki, Eiji

AU - Kuramata, Takashi

AU - Kozaki, Tetsuo

AU - Koyama, Tetsuya

AU - Kato, Yuji

AU - murakami, yusuke

AU - Enaida, Hiroshi

AU - Ishibashi, Tatsuro

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Purpose: Patients in the early stage of retinitis pigmentosa (RP) suffer from night blindness and, therefore, have mobility problems at night. To assist such patients with walking in the dark, we developed a wearable visual aid utilizing a see-through display upon which assistive images from a high-sensitivity video camera are superimposed. We evaluated the efficacy of our new visual aid for RP patients. Methods: The device is equipped with a camera with a minimum illuminance of 0.08 lux and a view angle of 53° × 40°. The experiment was conducted in a room with dimmed light (illuminance level 0.2–1.2 lux). Eight subjects with RP were instructed to arrive at a goal 16 m away from the starting point, both with and without the device, passing through four 1.5-m-wide gates consisting of pairs of black square carpet pieces, white poles, red and white traffic cones and cardboard boxes with and without the device in a darkened room. Three gates, except for the boxes, which were nearest the goal, were randomly arranged along the x-axis at each trial. The number of trial failures and the time required to walk the course were assessed as outcomes. Results: Seven of the 8 subjects could walk with the aid of the device without any failure. With the device, the number of trial failures significantly decreased in number (p < 0.05) in all subjects. Conclusions: This device enabled the subjects to see objects that could not be recognized by the unaided eye. Our visual aid effectively assisted RP patients with night blindness.

AB - Purpose: Patients in the early stage of retinitis pigmentosa (RP) suffer from night blindness and, therefore, have mobility problems at night. To assist such patients with walking in the dark, we developed a wearable visual aid utilizing a see-through display upon which assistive images from a high-sensitivity video camera are superimposed. We evaluated the efficacy of our new visual aid for RP patients. Methods: The device is equipped with a camera with a minimum illuminance of 0.08 lux and a view angle of 53° × 40°. The experiment was conducted in a room with dimmed light (illuminance level 0.2–1.2 lux). Eight subjects with RP were instructed to arrive at a goal 16 m away from the starting point, both with and without the device, passing through four 1.5-m-wide gates consisting of pairs of black square carpet pieces, white poles, red and white traffic cones and cardboard boxes with and without the device in a darkened room. Three gates, except for the boxes, which were nearest the goal, were randomly arranged along the x-axis at each trial. The number of trial failures and the time required to walk the course were assessed as outcomes. Results: Seven of the 8 subjects could walk with the aid of the device without any failure. With the device, the number of trial failures significantly decreased in number (p < 0.05) in all subjects. Conclusions: This device enabled the subjects to see objects that could not be recognized by the unaided eye. Our visual aid effectively assisted RP patients with night blindness.

UR - http://www.scopus.com/inward/record.url?scp=84937511247&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937511247&partnerID=8YFLogxK

U2 - 10.1007/s10384-014-0354-0

DO - 10.1007/s10384-014-0354-0

M3 - Article

C2 - 25352068

AN - SCOPUS:84937511247

VL - 59

SP - 43

EP - 47

JO - Japanese Journal of Ophthalmology

JF - Japanese Journal of Ophthalmology

SN - 0021-5155

IS - 1

ER -