TY - JOUR
T1 - Development of a 22/43 GHz-band quasi-optical perforated plate and dual-band observation system of the Nobeyama 45 m telescope
AU - Okada, Nozomi
AU - Hashimoto, Ikumi
AU - Kimura, Kimihiro
AU - Manabe, Takeshi
AU - Tokuda, Kazuki
AU - Onishi, Toshikazu
AU - Ogawa, Hideo
AU - Imai, Hiroshi
AU - Minamidani, Tetsuhiro
N1 - Funding Information:
This work was supported by the KAKENHI program (16H02167) and the Joint Development Research supported by the Research Coordination Committee, National Astronomical Observatory of Japan (NAOJ), National Institutes of Natural Sciences (NINS).
Publisher Copyright:
© 2019 The Author(s) 2019. Published by Oxford University Press on behalf of the Astronomical Society of Japan.
PY - 2019/9/1
Y1 - 2019/9/1
N2 - We have developed a system of simultaneous observations in the 22 and 43 GHz bands using the Nobeyama 45 m telescope, and are also working to add the 86 GHz band. Multi-frequency observations are realized by mounting perforated plates in the optics as dichroic frequency-selective devices. This paper presents the development of the perforated plate for the 22 and 43 GHz bands and the results of the commissioning observations with this plate on the Nobeyama 45 m telescope. The perforated plate is designed to be installed in the large telescope optics with a physical beam diameter as large as $50\:$cm for transmitting the higher frequency (43 GHz) band and for reflecting the lower frequency (22 GHz) band. The developed plate achieves an insertion loss of $0.22\:$dB (5%) at $43\:$GHz. The effects of the mounted plate on the systematic offsets and on the accuracy degradation of pointing were confirmed to be negligible. The differences in the main-beam/aperture efficiencies from those without the plate were confirmed to be within a few percent points. In addition, we successfully detected interferometry fringes in a very long baseline interferometry (VLBI) observation using the 45 m telescope and the VLBI Exploration of Radio Astrometry (VERA) 20 m telescopes, which confirmed that the dual-band observation system is operationally effective in both single-dish and VLBI observations.
AB - We have developed a system of simultaneous observations in the 22 and 43 GHz bands using the Nobeyama 45 m telescope, and are also working to add the 86 GHz band. Multi-frequency observations are realized by mounting perforated plates in the optics as dichroic frequency-selective devices. This paper presents the development of the perforated plate for the 22 and 43 GHz bands and the results of the commissioning observations with this plate on the Nobeyama 45 m telescope. The perforated plate is designed to be installed in the large telescope optics with a physical beam diameter as large as $50\:$cm for transmitting the higher frequency (43 GHz) band and for reflecting the lower frequency (22 GHz) band. The developed plate achieves an insertion loss of $0.22\:$dB (5%) at $43\:$GHz. The effects of the mounted plate on the systematic offsets and on the accuracy degradation of pointing were confirmed to be negligible. The differences in the main-beam/aperture efficiencies from those without the plate were confirmed to be within a few percent points. In addition, we successfully detected interferometry fringes in a very long baseline interferometry (VLBI) observation using the 45 m telescope and the VLBI Exploration of Radio Astrometry (VERA) 20 m telescopes, which confirmed that the dual-band observation system is operationally effective in both single-dish and VLBI observations.
UR - http://www.scopus.com/inward/record.url?scp=85106791675&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85106791675&partnerID=8YFLogxK
U2 - 10.1093/pasj/psz126
DO - 10.1093/pasj/psz126
M3 - Article
AN - SCOPUS:85106791675
SN - 0021-924X
VL - 166
JO - Journal of Biochemistry
JF - Journal of Biochemistry
IS - 3
M1 - 7
ER -