TY - JOUR
T1 - Development of a computational phantom for validation of automated noise measurement in CT images
AU - Anam, Choirul
AU - Sutanto, Heri
AU - Adi, Kusworo
AU - Budi, Wahyu Setia
AU - Muhlisin, Zaenul
AU - Haryanto, Freddy
AU - Matsubara, Kosuke
AU - Fujibuchi, Toshioh
AU - Dougherty, Geoff
N1 - Funding Information:
This work was funded by the Riset Publikasi Internasional Bereputasi Tinggi (RPIBT), Diponegoro University (Contract Number: 329-116/UN7.P4.3/ PP/2019).
Publisher Copyright:
© 2020 IOP Publishing Ltd
PY - 2020/11
Y1 - 2020/11
N2 - The purpose of this study was to develop a computational phantom for validation of automatic noise calculations applied to all parts of the body, to investigate kernel size in determining noise, and to validate the accuracy of automatic noise calculation for several noise levels. The phantom consisted of objects with a very wide range of HU values, from −1000 to +950. The incremental value for each object was 10 HU. Each object had a size of 15 × 15 pixels separated by a distance of 5 pixels. There was no dominant homogeneous part in the phantom. The image of the phantom was then degraded to mimic the real image quality of CT by convolving it with a point spread function (PSF) and by addition of Gaussian noise. The magnitude of the Gaussian noises was varied (5, 10, 25, 50, 75 and 100 HUs), and they were considered as the ground truth noise (NG). We also used a computational phantom with added actual noise from a CT scanner. The phantom was used to validate the automated noise measurement based on the average of the ten smallest standard deviations (SD) from the standard deviation map (SDM). Kernel sizes from 3 × 3 up to 27 × 27 pixels were examined in this study. A computational phantom for automated noise calculations validation has been successfully developed. It was found that the measured noise (NM) was influenced by the kernel size. For kernels of 15 × 15 pixels or smaller, the NM value was much smaller than the NG. For kernel sizes from 17 × 17 to 21 × 21 pixels, the NM value was about 90% of NG. And for kernel sizes of 23 × 23 pixels and above, NM is greater than NG. It was also found that even with small kernel sizes the relationship between NM and NG is linear with R2 more than 0.995. Thus accurate noise levels can be automatically obtained even with small kernel sizes without any concern regarding the inhomogeneity of the object.
AB - The purpose of this study was to develop a computational phantom for validation of automatic noise calculations applied to all parts of the body, to investigate kernel size in determining noise, and to validate the accuracy of automatic noise calculation for several noise levels. The phantom consisted of objects with a very wide range of HU values, from −1000 to +950. The incremental value for each object was 10 HU. Each object had a size of 15 × 15 pixels separated by a distance of 5 pixels. There was no dominant homogeneous part in the phantom. The image of the phantom was then degraded to mimic the real image quality of CT by convolving it with a point spread function (PSF) and by addition of Gaussian noise. The magnitude of the Gaussian noises was varied (5, 10, 25, 50, 75 and 100 HUs), and they were considered as the ground truth noise (NG). We also used a computational phantom with added actual noise from a CT scanner. The phantom was used to validate the automated noise measurement based on the average of the ten smallest standard deviations (SD) from the standard deviation map (SDM). Kernel sizes from 3 × 3 up to 27 × 27 pixels were examined in this study. A computational phantom for automated noise calculations validation has been successfully developed. It was found that the measured noise (NM) was influenced by the kernel size. For kernels of 15 × 15 pixels or smaller, the NM value was much smaller than the NG. For kernel sizes from 17 × 17 to 21 × 21 pixels, the NM value was about 90% of NG. And for kernel sizes of 23 × 23 pixels and above, NM is greater than NG. It was also found that even with small kernel sizes the relationship between NM and NG is linear with R2 more than 0.995. Thus accurate noise levels can be automatically obtained even with small kernel sizes without any concern regarding the inhomogeneity of the object.
UR - http://www.scopus.com/inward/record.url?scp=85092794699&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85092794699&partnerID=8YFLogxK
U2 - 10.1088/2057-1976/abb2f8
DO - 10.1088/2057-1976/abb2f8
M3 - Article
C2 - 35135906
AN - SCOPUS:85092794699
SN - 2057-1976
VL - 6
JO - Biomedical Physics and Engineering Express
JF - Biomedical Physics and Engineering Express
IS - 6
M1 - A1
ER -