TY - JOUR
T1 - Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography
AU - Sakai, Miho
AU - Hayakawa, Yoshihiro
AU - Funada, Yasuhiro
AU - Ando, Takashi
AU - Fukusaki, Eiichiro
AU - Bamba, Takeshi
N1 - Publisher Copyright:
© 2017
PY - 2017/9/15
Y1 - 2017/9/15
N2 - In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔPcolumnsideinsplitless and ΔPcolumnsideinsplit, respectively, where ΔPcolumnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop.
AB - In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔPcolumnsideinsplitless and ΔPcolumnsideinsplit, respectively, where ΔPcolumnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop.
UR - http://www.scopus.com/inward/record.url?scp=85027276906&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85027276906&partnerID=8YFLogxK
U2 - 10.1016/j.chroma.2017.07.077
DO - 10.1016/j.chroma.2017.07.077
M3 - Article
C2 - 28802523
AN - SCOPUS:85027276906
SN - 0021-9673
VL - 1515
SP - 218
EP - 231
JO - Journal of Chromatography A
JF - Journal of Chromatography A
ER -