Development of an automated method for evaluation of sharpness of digital radiographs using edge method

I. Kawashita, K. Maeda, Hidetaka Arimura, K. Morikawa, T. Ishida

Research output: Contribution to journalConference article

5 Citations (Scopus)

Abstract

The presampling modulation transfer function (MTF) can be determined by the edge spread function (ESF) in which the sampling interval is narrower than the pixel-to-pixel interval from slight angled edge image. It is important that the precision of the presampling MTF depend on the precision of the edge angle. In this study, we have developed the automated method, which includes a precise edge angle determination process for the measurement of the presampling MTF. To determine the precise edge angle, we employed the image projection technique of the Sobel output image. The image projection technique includes an image rotation in all direction (360-degree) and the integration of the Sobel output along the vertical center band. The edge angle is determined when the output value of the projection becomes maximum. We compared the difference between the presampling MTFs obtained by the slit method and the edge method. The presampling MTFs of the computed radiography (CR) system obtained by the edge method was comparable to those of the slit method. The method in this study is easy and sufficient for the quantitative evaluation of resolution property of digital imaging system.

Original languageEnglish
Pages (from-to)331-338
Number of pages8
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume4320
DOIs
Publication statusPublished - Jan 1 2001
Externally publishedYes
EventMedical Imaging 2001: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 18 2001Feb 20 2001

Fingerprint

sharpness
Optical transfer function
Sharpness
modulation transfer function
evaluation
Evaluation
Pixels
Transfer Function
Angle
Modulation
Radiography
Projection
Imaging systems
Output
projection
Pixel
Sampling
slits
Digital Imaging
output

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

Cite this

Development of an automated method for evaluation of sharpness of digital radiographs using edge method. / Kawashita, I.; Maeda, K.; Arimura, Hidetaka; Morikawa, K.; Ishida, T.

In: Proceedings of SPIE - The International Society for Optical Engineering, Vol. 4320, 01.01.2001, p. 331-338.

Research output: Contribution to journalConference article

@article{62ee6a77b6f54df3ae6a3bea830370f1,
title = "Development of an automated method for evaluation of sharpness of digital radiographs using edge method",
abstract = "The presampling modulation transfer function (MTF) can be determined by the edge spread function (ESF) in which the sampling interval is narrower than the pixel-to-pixel interval from slight angled edge image. It is important that the precision of the presampling MTF depend on the precision of the edge angle. In this study, we have developed the automated method, which includes a precise edge angle determination process for the measurement of the presampling MTF. To determine the precise edge angle, we employed the image projection technique of the Sobel output image. The image projection technique includes an image rotation in all direction (360-degree) and the integration of the Sobel output along the vertical center band. The edge angle is determined when the output value of the projection becomes maximum. We compared the difference between the presampling MTFs obtained by the slit method and the edge method. The presampling MTFs of the computed radiography (CR) system obtained by the edge method was comparable to those of the slit method. The method in this study is easy and sufficient for the quantitative evaluation of resolution property of digital imaging system.",
author = "I. Kawashita and K. Maeda and Hidetaka Arimura and K. Morikawa and T. Ishida",
year = "2001",
month = "1",
day = "1",
doi = "10.1117/12.430929",
language = "English",
volume = "4320",
pages = "331--338",
journal = "Proceedings of SPIE - The International Society for Optical Engineering",
issn = "0277-786X",
publisher = "SPIE",

}

TY - JOUR

T1 - Development of an automated method for evaluation of sharpness of digital radiographs using edge method

AU - Kawashita, I.

AU - Maeda, K.

AU - Arimura, Hidetaka

AU - Morikawa, K.

AU - Ishida, T.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - The presampling modulation transfer function (MTF) can be determined by the edge spread function (ESF) in which the sampling interval is narrower than the pixel-to-pixel interval from slight angled edge image. It is important that the precision of the presampling MTF depend on the precision of the edge angle. In this study, we have developed the automated method, which includes a precise edge angle determination process for the measurement of the presampling MTF. To determine the precise edge angle, we employed the image projection technique of the Sobel output image. The image projection technique includes an image rotation in all direction (360-degree) and the integration of the Sobel output along the vertical center band. The edge angle is determined when the output value of the projection becomes maximum. We compared the difference between the presampling MTFs obtained by the slit method and the edge method. The presampling MTFs of the computed radiography (CR) system obtained by the edge method was comparable to those of the slit method. The method in this study is easy and sufficient for the quantitative evaluation of resolution property of digital imaging system.

AB - The presampling modulation transfer function (MTF) can be determined by the edge spread function (ESF) in which the sampling interval is narrower than the pixel-to-pixel interval from slight angled edge image. It is important that the precision of the presampling MTF depend on the precision of the edge angle. In this study, we have developed the automated method, which includes a precise edge angle determination process for the measurement of the presampling MTF. To determine the precise edge angle, we employed the image projection technique of the Sobel output image. The image projection technique includes an image rotation in all direction (360-degree) and the integration of the Sobel output along the vertical center band. The edge angle is determined when the output value of the projection becomes maximum. We compared the difference between the presampling MTFs obtained by the slit method and the edge method. The presampling MTFs of the computed radiography (CR) system obtained by the edge method was comparable to those of the slit method. The method in this study is easy and sufficient for the quantitative evaluation of resolution property of digital imaging system.

UR - http://www.scopus.com/inward/record.url?scp=0034860507&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034860507&partnerID=8YFLogxK

U2 - 10.1117/12.430929

DO - 10.1117/12.430929

M3 - Conference article

AN - SCOPUS:0034860507

VL - 4320

SP - 331

EP - 338

JO - Proceedings of SPIE - The International Society for Optical Engineering

JF - Proceedings of SPIE - The International Society for Optical Engineering

SN - 0277-786X

ER -