We develop a monitor system to control a parallel-type superconducting (SC) level sensor and to indicate the level of liquid hydrogen in a container. The parallel-type level sensor is composed of an MgB2 wire and non-SC wire, which are vertically located in parallel and electrically connected in series. We assemble the monitor unit using a power supply, central processing unit (CPU), analog-to-digital (AD)/digital-to-analog (DA) converter, touch panel, voltage dividers and isolators. The terminal voltages of the MgB2 wire and non-SC wire with a constant current produced by the power supply are stored in the memory of CPU through the isolators, voltage dividers and AD converter. The liquid level is calculated in the CPU according to a pre-written program code. The obtained result is displayed on the touch panel and also output externally via the DA converter and isolator. Furthermore, the normal operation of the developed monitor system is validated using dummy voltages from an oscillator.

Original languageEnglish
Article number012041
JournalJournal of Physics: Conference Series
Volume1293
Issue number1
DOIs
Publication statusPublished - Oct 15 2019
Event31st International Symposium on Superconductivity, ISS 2018 - Tsukuba, Ibaraki, Japan
Duration: Dec 12 2018Dec 14 2018

Fingerprint

liquid hydrogen
monitors
isolators
wire
digital to analog converters
central processing units
touch
dividers
sensors
electric potential
power supplies
liquid levels
dummies
analog to digital converters
containers
oscillators
analogs
output

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

Cite this

Development of monitor system for parallel-type superconducting level sensor for liquid hydrogen. / Tanaka, Naoki; Kajikawa, Kazuhiro; Oguro, Hidetoshi; Sugino, Makoto; Nakanishi, Tsutomu; Aoki, Itsuo.

In: Journal of Physics: Conference Series, Vol. 1293, No. 1, 012041, 15.10.2019.

Research output: Contribution to journalConference article

Tanaka, Naoki ; Kajikawa, Kazuhiro ; Oguro, Hidetoshi ; Sugino, Makoto ; Nakanishi, Tsutomu ; Aoki, Itsuo. / Development of monitor system for parallel-type superconducting level sensor for liquid hydrogen. In: Journal of Physics: Conference Series. 2019 ; Vol. 1293, No. 1.
@article{7f891d1e79dd4c9d8c50a04c90a67d07,
title = "Development of monitor system for parallel-type superconducting level sensor for liquid hydrogen",
abstract = "We develop a monitor system to control a parallel-type superconducting (SC) level sensor and to indicate the level of liquid hydrogen in a container. The parallel-type level sensor is composed of an MgB2 wire and non-SC wire, which are vertically located in parallel and electrically connected in series. We assemble the monitor unit using a power supply, central processing unit (CPU), analog-to-digital (AD)/digital-to-analog (DA) converter, touch panel, voltage dividers and isolators. The terminal voltages of the MgB2 wire and non-SC wire with a constant current produced by the power supply are stored in the memory of CPU through the isolators, voltage dividers and AD converter. The liquid level is calculated in the CPU according to a pre-written program code. The obtained result is displayed on the touch panel and also output externally via the DA converter and isolator. Furthermore, the normal operation of the developed monitor system is validated using dummy voltages from an oscillator.",
author = "Naoki Tanaka and Kazuhiro Kajikawa and Hidetoshi Oguro and Makoto Sugino and Tsutomu Nakanishi and Itsuo Aoki",
year = "2019",
month = "10",
day = "15",
doi = "10.1088/1742-6596/1293/1/012041",
language = "English",
volume = "1293",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Development of monitor system for parallel-type superconducting level sensor for liquid hydrogen

AU - Tanaka, Naoki

AU - Kajikawa, Kazuhiro

AU - Oguro, Hidetoshi

AU - Sugino, Makoto

AU - Nakanishi, Tsutomu

AU - Aoki, Itsuo

PY - 2019/10/15

Y1 - 2019/10/15

N2 - We develop a monitor system to control a parallel-type superconducting (SC) level sensor and to indicate the level of liquid hydrogen in a container. The parallel-type level sensor is composed of an MgB2 wire and non-SC wire, which are vertically located in parallel and electrically connected in series. We assemble the monitor unit using a power supply, central processing unit (CPU), analog-to-digital (AD)/digital-to-analog (DA) converter, touch panel, voltage dividers and isolators. The terminal voltages of the MgB2 wire and non-SC wire with a constant current produced by the power supply are stored in the memory of CPU through the isolators, voltage dividers and AD converter. The liquid level is calculated in the CPU according to a pre-written program code. The obtained result is displayed on the touch panel and also output externally via the DA converter and isolator. Furthermore, the normal operation of the developed monitor system is validated using dummy voltages from an oscillator.

AB - We develop a monitor system to control a parallel-type superconducting (SC) level sensor and to indicate the level of liquid hydrogen in a container. The parallel-type level sensor is composed of an MgB2 wire and non-SC wire, which are vertically located in parallel and electrically connected in series. We assemble the monitor unit using a power supply, central processing unit (CPU), analog-to-digital (AD)/digital-to-analog (DA) converter, touch panel, voltage dividers and isolators. The terminal voltages of the MgB2 wire and non-SC wire with a constant current produced by the power supply are stored in the memory of CPU through the isolators, voltage dividers and AD converter. The liquid level is calculated in the CPU according to a pre-written program code. The obtained result is displayed on the touch panel and also output externally via the DA converter and isolator. Furthermore, the normal operation of the developed monitor system is validated using dummy voltages from an oscillator.

UR - http://www.scopus.com/inward/record.url?scp=85075943800&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85075943800&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/1293/1/012041

DO - 10.1088/1742-6596/1293/1/012041

M3 - Conference article

AN - SCOPUS:85075943800

VL - 1293

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012041

ER -