Development of new mechanical shear connector using burring steel plate

Teruhisa Tanaka, Junichi Sakai, Akihiko Kawano

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This research is development of new mechanical shear connector for joining steel and concrete which expected high-strength and high-stiffness. It is a steel plate using burring which is a kind of machining, and calls it "Burring shear connector". Inorder to examine the effectiveness of the burring steel plate, we performed a basic experiment (push-out test) which pushes steel with them outside from concrete block. The experimental parameter was the flange heights. A headed stud and a perfobond plate connector (PBL), which is the common type of shear connector, were also tested for the purpose of comparison. From the result of the experiment, the burring shear connector showed a good resistance performance as compared with the conventional mechanical shear connectors.

Original languageEnglish
Pages (from-to)2237-2245
Number of pages9
JournalJournal of Structural and Construction Engineering
Volume78
Issue number694
DOIs
Publication statusPublished - Jan 1 2013

Fingerprint

Steel
Connectors (structural)
Concrete blocks
Flanges
Joining
Machining
Experiments
Stiffness
Concretes

All Science Journal Classification (ASJC) codes

  • Architecture
  • Building and Construction

Cite this

Development of new mechanical shear connector using burring steel plate. / Tanaka, Teruhisa; Sakai, Junichi; Kawano, Akihiko.

In: Journal of Structural and Construction Engineering, Vol. 78, No. 694, 01.01.2013, p. 2237-2245.

Research output: Contribution to journalArticle

Tanaka, Teruhisa ; Sakai, Junichi ; Kawano, Akihiko. / Development of new mechanical shear connector using burring steel plate. In: Journal of Structural and Construction Engineering. 2013 ; Vol. 78, No. 694. pp. 2237-2245.
@article{29f324f0efe74741a0f832c56ca8fcdf,
title = "Development of new mechanical shear connector using burring steel plate",
abstract = "This research is development of new mechanical shear connector for joining steel and concrete which expected high-strength and high-stiffness. It is a steel plate using burring which is a kind of machining, and calls it {"}Burring shear connector{"}. Inorder to examine the effectiveness of the burring steel plate, we performed a basic experiment (push-out test) which pushes steel with them outside from concrete block. The experimental parameter was the flange heights. A headed stud and a perfobond plate connector (PBL), which is the common type of shear connector, were also tested for the purpose of comparison. From the result of the experiment, the burring shear connector showed a good resistance performance as compared with the conventional mechanical shear connectors.",
author = "Teruhisa Tanaka and Junichi Sakai and Akihiko Kawano",
year = "2013",
month = "1",
day = "1",
doi = "10.3130/aijs.78.2237",
language = "English",
volume = "78",
pages = "2237--2245",
journal = "Journal of Structural and Construction Engineering",
issn = "1340-4202",
publisher = "日本建築学会",
number = "694",

}

TY - JOUR

T1 - Development of new mechanical shear connector using burring steel plate

AU - Tanaka, Teruhisa

AU - Sakai, Junichi

AU - Kawano, Akihiko

PY - 2013/1/1

Y1 - 2013/1/1

N2 - This research is development of new mechanical shear connector for joining steel and concrete which expected high-strength and high-stiffness. It is a steel plate using burring which is a kind of machining, and calls it "Burring shear connector". Inorder to examine the effectiveness of the burring steel plate, we performed a basic experiment (push-out test) which pushes steel with them outside from concrete block. The experimental parameter was the flange heights. A headed stud and a perfobond plate connector (PBL), which is the common type of shear connector, were also tested for the purpose of comparison. From the result of the experiment, the burring shear connector showed a good resistance performance as compared with the conventional mechanical shear connectors.

AB - This research is development of new mechanical shear connector for joining steel and concrete which expected high-strength and high-stiffness. It is a steel plate using burring which is a kind of machining, and calls it "Burring shear connector". Inorder to examine the effectiveness of the burring steel plate, we performed a basic experiment (push-out test) which pushes steel with them outside from concrete block. The experimental parameter was the flange heights. A headed stud and a perfobond plate connector (PBL), which is the common type of shear connector, were also tested for the purpose of comparison. From the result of the experiment, the burring shear connector showed a good resistance performance as compared with the conventional mechanical shear connectors.

UR - http://www.scopus.com/inward/record.url?scp=84904187823&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904187823&partnerID=8YFLogxK

U2 - 10.3130/aijs.78.2237

DO - 10.3130/aijs.78.2237

M3 - Article

VL - 78

SP - 2237

EP - 2245

JO - Journal of Structural and Construction Engineering

JF - Journal of Structural and Construction Engineering

SN - 1340-4202

IS - 694

ER -