Development of the horror emotion amplification system by means of biofeedback method

Ryoko Ueoka, Kouya Ishigaki

Research output: Chapter in Book/Report/Conference proceedingConference contribution

5 Citations (Scopus)

Abstract

Current 3D digital film gives us a more realistic sensation. However there is still some problem that keeps us away from immersing the horror contents. In order to find an effective way to amplify horror emotion to viewers, we propose cross modal display system to enhance horror emotion. As a first step, we developed a pseudo heart beat feedback system to give vibrotactile feedback. We made a locker-type 3d movie watching environment while generating heart beat-like vibration on the sole of the foot. We conducted the experiment to view the horror movie with the system. In this experiment, we gave two types of pseudo heart beat vibration. One is to raise heart beat vibration by referring a user’s heart rate real time. Other is to raise heart beat vibration in a stepwise manner up to predetermined heart rate value. We evaluated which method is effective to raise viewer’s real heartbeat.

Original languageEnglish
Title of host publicationHuman Interface and the Management of Information
Subtitle of host publicationInformation and Knowledge in Context - 17th International Conference, HCI International 2015, Proceedings
EditorsSakae Yamamoto
PublisherSpringer Verlag
Pages657-665
Number of pages9
ISBN (Print)9783319206172
DOIs
Publication statusPublished - Jan 1 2015
Event17th International Conference on Human-Computer Interaction, HCI International 2015 - Los Angeles, United States
Duration: Aug 2 2015Aug 7 2015

Publication series

NameLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
Volume9173
ISSN (Print)0302-9743
ISSN (Electronic)1611-3349

Other

Other17th International Conference on Human-Computer Interaction, HCI International 2015
CountryUnited States
CityLos Angeles
Period8/2/158/7/15

Fingerprint

Biofeedback
Beat
Amplification
Vibration
Heart Rate
Feedback Systems
Feedback
Experiment
Display
Emotion
Heart
Experiments
Display devices

All Science Journal Classification (ASJC) codes

  • Theoretical Computer Science
  • Computer Science(all)

Cite this

Ueoka, R., & Ishigaki, K. (2015). Development of the horror emotion amplification system by means of biofeedback method. In S. Yamamoto (Ed.), Human Interface and the Management of Information: Information and Knowledge in Context - 17th International Conference, HCI International 2015, Proceedings (pp. 657-665). (Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics); Vol. 9173). Springer Verlag. https://doi.org/10.1007/978-3-319-20618-9_64

Development of the horror emotion amplification system by means of biofeedback method. / Ueoka, Ryoko; Ishigaki, Kouya.

Human Interface and the Management of Information: Information and Knowledge in Context - 17th International Conference, HCI International 2015, Proceedings. ed. / Sakae Yamamoto. Springer Verlag, 2015. p. 657-665 (Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics); Vol. 9173).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ueoka, R & Ishigaki, K 2015, Development of the horror emotion amplification system by means of biofeedback method. in S Yamamoto (ed.), Human Interface and the Management of Information: Information and Knowledge in Context - 17th International Conference, HCI International 2015, Proceedings. Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), vol. 9173, Springer Verlag, pp. 657-665, 17th International Conference on Human-Computer Interaction, HCI International 2015, Los Angeles, United States, 8/2/15. https://doi.org/10.1007/978-3-319-20618-9_64
Ueoka R, Ishigaki K. Development of the horror emotion amplification system by means of biofeedback method. In Yamamoto S, editor, Human Interface and the Management of Information: Information and Knowledge in Context - 17th International Conference, HCI International 2015, Proceedings. Springer Verlag. 2015. p. 657-665. (Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)). https://doi.org/10.1007/978-3-319-20618-9_64
Ueoka, Ryoko ; Ishigaki, Kouya. / Development of the horror emotion amplification system by means of biofeedback method. Human Interface and the Management of Information: Information and Knowledge in Context - 17th International Conference, HCI International 2015, Proceedings. editor / Sakae Yamamoto. Springer Verlag, 2015. pp. 657-665 (Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)).
@inproceedings{30b8732f2e8d4bb8b140a09adb3c0766,
title = "Development of the horror emotion amplification system by means of biofeedback method",
abstract = "Current 3D digital film gives us a more realistic sensation. However there is still some problem that keeps us away from immersing the horror contents. In order to find an effective way to amplify horror emotion to viewers, we propose cross modal display system to enhance horror emotion. As a first step, we developed a pseudo heart beat feedback system to give vibrotactile feedback. We made a locker-type 3d movie watching environment while generating heart beat-like vibration on the sole of the foot. We conducted the experiment to view the horror movie with the system. In this experiment, we gave two types of pseudo heart beat vibration. One is to raise heart beat vibration by referring a user’s heart rate real time. Other is to raise heart beat vibration in a stepwise manner up to predetermined heart rate value. We evaluated which method is effective to raise viewer’s real heartbeat.",
author = "Ryoko Ueoka and Kouya Ishigaki",
year = "2015",
month = "1",
day = "1",
doi = "10.1007/978-3-319-20618-9_64",
language = "English",
isbn = "9783319206172",
series = "Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)",
publisher = "Springer Verlag",
pages = "657--665",
editor = "Sakae Yamamoto",
booktitle = "Human Interface and the Management of Information",
address = "Germany",

}

TY - GEN

T1 - Development of the horror emotion amplification system by means of biofeedback method

AU - Ueoka, Ryoko

AU - Ishigaki, Kouya

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Current 3D digital film gives us a more realistic sensation. However there is still some problem that keeps us away from immersing the horror contents. In order to find an effective way to amplify horror emotion to viewers, we propose cross modal display system to enhance horror emotion. As a first step, we developed a pseudo heart beat feedback system to give vibrotactile feedback. We made a locker-type 3d movie watching environment while generating heart beat-like vibration on the sole of the foot. We conducted the experiment to view the horror movie with the system. In this experiment, we gave two types of pseudo heart beat vibration. One is to raise heart beat vibration by referring a user’s heart rate real time. Other is to raise heart beat vibration in a stepwise manner up to predetermined heart rate value. We evaluated which method is effective to raise viewer’s real heartbeat.

AB - Current 3D digital film gives us a more realistic sensation. However there is still some problem that keeps us away from immersing the horror contents. In order to find an effective way to amplify horror emotion to viewers, we propose cross modal display system to enhance horror emotion. As a first step, we developed a pseudo heart beat feedback system to give vibrotactile feedback. We made a locker-type 3d movie watching environment while generating heart beat-like vibration on the sole of the foot. We conducted the experiment to view the horror movie with the system. In this experiment, we gave two types of pseudo heart beat vibration. One is to raise heart beat vibration by referring a user’s heart rate real time. Other is to raise heart beat vibration in a stepwise manner up to predetermined heart rate value. We evaluated which method is effective to raise viewer’s real heartbeat.

UR - http://www.scopus.com/inward/record.url?scp=84947232515&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84947232515&partnerID=8YFLogxK

U2 - 10.1007/978-3-319-20618-9_64

DO - 10.1007/978-3-319-20618-9_64

M3 - Conference contribution

SN - 9783319206172

T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)

SP - 657

EP - 665

BT - Human Interface and the Management of Information

A2 - Yamamoto, Sakae

PB - Springer Verlag

ER -