Dissolution method for the determination of silicon in plant samples with ICP-AES

Koich Akiyama, Tadashi Nakanishi, Ryo Ohnishi, Tasuku Akagi

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Dissolution methods for the determination of silicon in plant samples with inductively coupled plasma atomic emission spectrometry (ICP-AES) were examined. Plant samples (0.1 g) ashed by an electric furnace at 700°C were dissolved by three methods: an acid dissolution method, where the ashes were dissolved with a hydrochloric acid solution; an alkaline dissolution method, where the ashes were dissolved with a sodium carbonate solution; and an alkaline fusion method, where the ashes were fused with sodium carbonate salt. The effect of evaporation after dissolution was also examined. It was found that evaporation exerted a critical effect on the analytical results of silicon, i.e., complete evaporation reduced the results to about half that obtained with incomplete evaporation. Two tea leaf samples (commercial and sampled) with a low silicon concentration could be dissolved by all three methods when the resultant solution was followed by incomplete evaporation. The reproducibility of the silicon concentration with the alkaline dissolution method and acid dissolution method was about 3%, and the recovery of silicon after both methods was more than 95%. In the case of Magnolia leaves with a high silicon concentration, the alkaline dissolution method gave a greater concentration of silicon with better precision (5%) than the alkaline fusion method.

Original languageEnglish
Pages (from-to)1229-1232
Number of pages4
Journalbunseki kagaku
Volume53
Issue number11
DOIs
Publication statusPublished - Nov 1 2004

Fingerprint

Inductively coupled plasma
Silicon
Spectrometry
Ashes
Dissolution
Evaporation
Fusion reactions
Electric furnaces
Acids
Hydrochloric Acid
Salts
Recovery

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

Dissolution method for the determination of silicon in plant samples with ICP-AES. / Akiyama, Koich; Nakanishi, Tadashi; Ohnishi, Ryo; Akagi, Tasuku.

In: bunseki kagaku, Vol. 53, No. 11, 01.11.2004, p. 1229-1232.

Research output: Contribution to journalArticle

Akiyama, Koich ; Nakanishi, Tadashi ; Ohnishi, Ryo ; Akagi, Tasuku. / Dissolution method for the determination of silicon in plant samples with ICP-AES. In: bunseki kagaku. 2004 ; Vol. 53, No. 11. pp. 1229-1232.
@article{a20fc1ce6d57427e8e0b6ba6d4248b24,
title = "Dissolution method for the determination of silicon in plant samples with ICP-AES",
abstract = "Dissolution methods for the determination of silicon in plant samples with inductively coupled plasma atomic emission spectrometry (ICP-AES) were examined. Plant samples (0.1 g) ashed by an electric furnace at 700°C were dissolved by three methods: an acid dissolution method, where the ashes were dissolved with a hydrochloric acid solution; an alkaline dissolution method, where the ashes were dissolved with a sodium carbonate solution; and an alkaline fusion method, where the ashes were fused with sodium carbonate salt. The effect of evaporation after dissolution was also examined. It was found that evaporation exerted a critical effect on the analytical results of silicon, i.e., complete evaporation reduced the results to about half that obtained with incomplete evaporation. Two tea leaf samples (commercial and sampled) with a low silicon concentration could be dissolved by all three methods when the resultant solution was followed by incomplete evaporation. The reproducibility of the silicon concentration with the alkaline dissolution method and acid dissolution method was about 3{\%}, and the recovery of silicon after both methods was more than 95{\%}. In the case of Magnolia leaves with a high silicon concentration, the alkaline dissolution method gave a greater concentration of silicon with better precision (5{\%}) than the alkaline fusion method.",
author = "Koich Akiyama and Tadashi Nakanishi and Ryo Ohnishi and Tasuku Akagi",
year = "2004",
month = "11",
day = "1",
doi = "10.2116/bunsekikagaku.53.1229",
language = "English",
volume = "53",
pages = "1229--1232",
journal = "Bunseki Kagaku",
issn = "0525-1931",
publisher = "公益社団法人日本分析化学会",
number = "11",

}

TY - JOUR

T1 - Dissolution method for the determination of silicon in plant samples with ICP-AES

AU - Akiyama, Koich

AU - Nakanishi, Tadashi

AU - Ohnishi, Ryo

AU - Akagi, Tasuku

PY - 2004/11/1

Y1 - 2004/11/1

N2 - Dissolution methods for the determination of silicon in plant samples with inductively coupled plasma atomic emission spectrometry (ICP-AES) were examined. Plant samples (0.1 g) ashed by an electric furnace at 700°C were dissolved by three methods: an acid dissolution method, where the ashes were dissolved with a hydrochloric acid solution; an alkaline dissolution method, where the ashes were dissolved with a sodium carbonate solution; and an alkaline fusion method, where the ashes were fused with sodium carbonate salt. The effect of evaporation after dissolution was also examined. It was found that evaporation exerted a critical effect on the analytical results of silicon, i.e., complete evaporation reduced the results to about half that obtained with incomplete evaporation. Two tea leaf samples (commercial and sampled) with a low silicon concentration could be dissolved by all three methods when the resultant solution was followed by incomplete evaporation. The reproducibility of the silicon concentration with the alkaline dissolution method and acid dissolution method was about 3%, and the recovery of silicon after both methods was more than 95%. In the case of Magnolia leaves with a high silicon concentration, the alkaline dissolution method gave a greater concentration of silicon with better precision (5%) than the alkaline fusion method.

AB - Dissolution methods for the determination of silicon in plant samples with inductively coupled plasma atomic emission spectrometry (ICP-AES) were examined. Plant samples (0.1 g) ashed by an electric furnace at 700°C were dissolved by three methods: an acid dissolution method, where the ashes were dissolved with a hydrochloric acid solution; an alkaline dissolution method, where the ashes were dissolved with a sodium carbonate solution; and an alkaline fusion method, where the ashes were fused with sodium carbonate salt. The effect of evaporation after dissolution was also examined. It was found that evaporation exerted a critical effect on the analytical results of silicon, i.e., complete evaporation reduced the results to about half that obtained with incomplete evaporation. Two tea leaf samples (commercial and sampled) with a low silicon concentration could be dissolved by all three methods when the resultant solution was followed by incomplete evaporation. The reproducibility of the silicon concentration with the alkaline dissolution method and acid dissolution method was about 3%, and the recovery of silicon after both methods was more than 95%. In the case of Magnolia leaves with a high silicon concentration, the alkaline dissolution method gave a greater concentration of silicon with better precision (5%) than the alkaline fusion method.

UR - http://www.scopus.com/inward/record.url?scp=12144284432&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12144284432&partnerID=8YFLogxK

U2 - 10.2116/bunsekikagaku.53.1229

DO - 10.2116/bunsekikagaku.53.1229

M3 - Article

AN - SCOPUS:12144284432

VL - 53

SP - 1229

EP - 1232

JO - Bunseki Kagaku

JF - Bunseki Kagaku

SN - 0525-1931

IS - 11

ER -