Dynamic Characterstics of the Push-Pull DC to DC Converter

Masahito Shoyama, Koosuke Harada

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The dynamic characteristics of the push-pull dc to dcconverter are analyzed both theoretically and experimentally for the modes of operation which are caused by the interaction between magnetizing current of the transformer and that of the reactor. Among all six modes of operation, four modes are of the first-order system. In two out of the four modes, the instantaneous reactor current does not fall to zero at any point in the switching cycle.

Original languageEnglish
Pages (from-to)3-8
Number of pages6
JournalIEEE Transactions on Power Electronics
VolumePE-1
Issue number1
DOIs
Publication statusPublished - Jan 1986

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cite this