Effect of Hydrothermal Waves on Evaporation Distribution during Drop Evaporation

Yuki Fukatani, Takaaki Wakui, Suhaila Hussain, Masamichi Kohno, Yasuyuki Takata, Khellil Sefiane, Jungho Kim

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The objective of this study is to clarify physical mechanisms involved in the evaporation of small (a few microliters) sessile drops. We aim to understand the relation between local thermal information at the solid-liquid interface and overall evaporation. An infrared (IR) camera and a charge-coupled device (CCD) camera were used to determine the temperature and heat flux distribution at the solid-liquid interface and the profile of the evaporating drop, respectively. The temperature distribution at the solid-liquid interface was determined using a multilayer substrate consisting of a silicon wafer coated with a thin thermal insulator that is partially transparent to IR. The liquids used were water and FC-72. The evaporation rate of water drops was found to occur mostly at the contact line. However, the heat transfer distribution at the liquid-solid interface was relatively uniform, indicating the heat transferred from the wall must be transported within the drop to the contact line. The mechanisms by which this occurs have yet to be determined. In contrast, the evaporation rate of FC-72 drops where hydrothermal waves were present was found to be proportional to the liquid-vapor interface area rather than the circumference of the drop, indicating a more uniform distribution of evaporation.

Original languageEnglish
Pages (from-to)729-739
Number of pages11
JournalHeat Transfer Engineering
Volume37
Issue number7-8
DOIs
Publication statusPublished - May 23 2016

Fingerprint

liquid-solid interfaces
Evaporation
evaporation
evaporation rate
Liquids
cameras
Contacts (fluid mechanics)
liquid-vapor interfaces
circumferences
water
Infrared radiation
heat flux
charge coupled devices
temperature distribution
Water
heat transfer
insulators
wafers
CCD cameras
Silicon wafers

All Science Journal Classification (ASJC) codes

  • Condensed Matter Physics
  • Mechanical Engineering
  • Fluid Flow and Transfer Processes

Cite this

Effect of Hydrothermal Waves on Evaporation Distribution during Drop Evaporation. / Fukatani, Yuki; Wakui, Takaaki; Hussain, Suhaila; Kohno, Masamichi; Takata, Yasuyuki; Sefiane, Khellil; Kim, Jungho.

In: Heat Transfer Engineering, Vol. 37, No. 7-8, 23.05.2016, p. 729-739.

Research output: Contribution to journalArticle

Fukatani, Yuki ; Wakui, Takaaki ; Hussain, Suhaila ; Kohno, Masamichi ; Takata, Yasuyuki ; Sefiane, Khellil ; Kim, Jungho. / Effect of Hydrothermal Waves on Evaporation Distribution during Drop Evaporation. In: Heat Transfer Engineering. 2016 ; Vol. 37, No. 7-8. pp. 729-739.
@article{bc01616c3c9b4fe08013a9714c422653,
title = "Effect of Hydrothermal Waves on Evaporation Distribution during Drop Evaporation",
abstract = "The objective of this study is to clarify physical mechanisms involved in the evaporation of small (a few microliters) sessile drops. We aim to understand the relation between local thermal information at the solid-liquid interface and overall evaporation. An infrared (IR) camera and a charge-coupled device (CCD) camera were used to determine the temperature and heat flux distribution at the solid-liquid interface and the profile of the evaporating drop, respectively. The temperature distribution at the solid-liquid interface was determined using a multilayer substrate consisting of a silicon wafer coated with a thin thermal insulator that is partially transparent to IR. The liquids used were water and FC-72. The evaporation rate of water drops was found to occur mostly at the contact line. However, the heat transfer distribution at the liquid-solid interface was relatively uniform, indicating the heat transferred from the wall must be transported within the drop to the contact line. The mechanisms by which this occurs have yet to be determined. In contrast, the evaporation rate of FC-72 drops where hydrothermal waves were present was found to be proportional to the liquid-vapor interface area rather than the circumference of the drop, indicating a more uniform distribution of evaporation.",
author = "Yuki Fukatani and Takaaki Wakui and Suhaila Hussain and Masamichi Kohno and Yasuyuki Takata and Khellil Sefiane and Jungho Kim",
year = "2016",
month = "5",
day = "23",
doi = "10.1080/01457632.2015.1067103",
language = "English",
volume = "37",
pages = "729--739",
journal = "Heat Transfer Engineering",
issn = "0145-7632",
publisher = "Taylor and Francis Ltd.",
number = "7-8",

}

TY - JOUR

T1 - Effect of Hydrothermal Waves on Evaporation Distribution during Drop Evaporation

AU - Fukatani, Yuki

AU - Wakui, Takaaki

AU - Hussain, Suhaila

AU - Kohno, Masamichi

AU - Takata, Yasuyuki

AU - Sefiane, Khellil

AU - Kim, Jungho

PY - 2016/5/23

Y1 - 2016/5/23

N2 - The objective of this study is to clarify physical mechanisms involved in the evaporation of small (a few microliters) sessile drops. We aim to understand the relation between local thermal information at the solid-liquid interface and overall evaporation. An infrared (IR) camera and a charge-coupled device (CCD) camera were used to determine the temperature and heat flux distribution at the solid-liquid interface and the profile of the evaporating drop, respectively. The temperature distribution at the solid-liquid interface was determined using a multilayer substrate consisting of a silicon wafer coated with a thin thermal insulator that is partially transparent to IR. The liquids used were water and FC-72. The evaporation rate of water drops was found to occur mostly at the contact line. However, the heat transfer distribution at the liquid-solid interface was relatively uniform, indicating the heat transferred from the wall must be transported within the drop to the contact line. The mechanisms by which this occurs have yet to be determined. In contrast, the evaporation rate of FC-72 drops where hydrothermal waves were present was found to be proportional to the liquid-vapor interface area rather than the circumference of the drop, indicating a more uniform distribution of evaporation.

AB - The objective of this study is to clarify physical mechanisms involved in the evaporation of small (a few microliters) sessile drops. We aim to understand the relation between local thermal information at the solid-liquid interface and overall evaporation. An infrared (IR) camera and a charge-coupled device (CCD) camera were used to determine the temperature and heat flux distribution at the solid-liquid interface and the profile of the evaporating drop, respectively. The temperature distribution at the solid-liquid interface was determined using a multilayer substrate consisting of a silicon wafer coated with a thin thermal insulator that is partially transparent to IR. The liquids used were water and FC-72. The evaporation rate of water drops was found to occur mostly at the contact line. However, the heat transfer distribution at the liquid-solid interface was relatively uniform, indicating the heat transferred from the wall must be transported within the drop to the contact line. The mechanisms by which this occurs have yet to be determined. In contrast, the evaporation rate of FC-72 drops where hydrothermal waves were present was found to be proportional to the liquid-vapor interface area rather than the circumference of the drop, indicating a more uniform distribution of evaporation.

UR - http://www.scopus.com/inward/record.url?scp=84946944717&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84946944717&partnerID=8YFLogxK

U2 - 10.1080/01457632.2015.1067103

DO - 10.1080/01457632.2015.1067103

M3 - Article

AN - SCOPUS:84946944717

VL - 37

SP - 729

EP - 739

JO - Heat Transfer Engineering

JF - Heat Transfer Engineering

SN - 0145-7632

IS - 7-8

ER -