Effects of posterior pelvic tilt on anterior instability in total hip arthroplasty

A parametric experimental modeling evaluation

Taishi Sato, Yasuharu Nakashima, Akinobu Matsushita, Masanori Fujii, Yukihide Iwamoto

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Background Anterior dislocation is one of the concerns of patients with posterior pelvic tilt undergoing total hip arthroplasty. This study aimed to evaluate the magnitude of posterior pelvic tilt constituting a risk for anterior dislocation by measuring the range of motion until impingement and dislocation under various pelvic tilt. Methods Using a jig mounted prosthetic hip model, the ranges of external rotation at extension and internal rotation at flexion until reaching dislocation were tested. The site of impingement prior to dislocation was also recorded. Posterior pelvic tilt and the cup version were changed with 10 increments from 0 to 40 and from 10 retroversion to 30 anteversion, respectively. Effects of increasing femoral offset were also tested. We defined a required range of motion as having 30 external rotation at extension and 40 internal rotation at 90 flexion. Findings External rotation decreased in a posterior pelvic tilt-dependent manner. In the case with more than 20 posterior pelvic tilt, available external rotation extended beyond required range with the cup anteversion of 20. Decreasing cup anteversion improved external rotation, however, internal rotation decreased simultaneously. In the case with posterior pelvic tilt more than 20, only cup anteversion with 0 or 10 satisfied the required range of motion. A + 4 mm horizontal offset improved external rotation by 10 with delaying bony impingement. Interpretation More than 20 of posterior pelvic tilt may cause anterior instability and diminish the optimal range of cup version. Increasing the femoral offset improved external rotation without reducing internal rotation.

Original languageEnglish
Pages (from-to)178-181
Number of pages4
JournalClinical Biomechanics
Volume28
Issue number2
DOIs
Publication statusPublished - Feb 1 2013

Fingerprint

Arthroplasty
Hip
Articular Range of Motion
Thigh

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Orthopedics and Sports Medicine

Cite this

@article{857ccc11b84147c0a1eac6da613bf1ea,
title = "Effects of posterior pelvic tilt on anterior instability in total hip arthroplasty: A parametric experimental modeling evaluation",
abstract = "Background Anterior dislocation is one of the concerns of patients with posterior pelvic tilt undergoing total hip arthroplasty. This study aimed to evaluate the magnitude of posterior pelvic tilt constituting a risk for anterior dislocation by measuring the range of motion until impingement and dislocation under various pelvic tilt. Methods Using a jig mounted prosthetic hip model, the ranges of external rotation at extension and internal rotation at flexion until reaching dislocation were tested. The site of impingement prior to dislocation was also recorded. Posterior pelvic tilt and the cup version were changed with 10 increments from 0 to 40 and from 10 retroversion to 30 anteversion, respectively. Effects of increasing femoral offset were also tested. We defined a required range of motion as having 30 external rotation at extension and 40 internal rotation at 90 flexion. Findings External rotation decreased in a posterior pelvic tilt-dependent manner. In the case with more than 20 posterior pelvic tilt, available external rotation extended beyond required range with the cup anteversion of 20. Decreasing cup anteversion improved external rotation, however, internal rotation decreased simultaneously. In the case with posterior pelvic tilt more than 20, only cup anteversion with 0 or 10 satisfied the required range of motion. A + 4 mm horizontal offset improved external rotation by 10 with delaying bony impingement. Interpretation More than 20 of posterior pelvic tilt may cause anterior instability and diminish the optimal range of cup version. Increasing the femoral offset improved external rotation without reducing internal rotation.",
author = "Taishi Sato and Yasuharu Nakashima and Akinobu Matsushita and Masanori Fujii and Yukihide Iwamoto",
year = "2013",
month = "2",
day = "1",
doi = "10.1016/j.clinbiomech.2012.12.011",
language = "English",
volume = "28",
pages = "178--181",
journal = "Clinical Biomechanics",
issn = "0268-0033",
publisher = "Elsevier Limited",
number = "2",

}

TY - JOUR

T1 - Effects of posterior pelvic tilt on anterior instability in total hip arthroplasty

T2 - A parametric experimental modeling evaluation

AU - Sato, Taishi

AU - Nakashima, Yasuharu

AU - Matsushita, Akinobu

AU - Fujii, Masanori

AU - Iwamoto, Yukihide

PY - 2013/2/1

Y1 - 2013/2/1

N2 - Background Anterior dislocation is one of the concerns of patients with posterior pelvic tilt undergoing total hip arthroplasty. This study aimed to evaluate the magnitude of posterior pelvic tilt constituting a risk for anterior dislocation by measuring the range of motion until impingement and dislocation under various pelvic tilt. Methods Using a jig mounted prosthetic hip model, the ranges of external rotation at extension and internal rotation at flexion until reaching dislocation were tested. The site of impingement prior to dislocation was also recorded. Posterior pelvic tilt and the cup version were changed with 10 increments from 0 to 40 and from 10 retroversion to 30 anteversion, respectively. Effects of increasing femoral offset were also tested. We defined a required range of motion as having 30 external rotation at extension and 40 internal rotation at 90 flexion. Findings External rotation decreased in a posterior pelvic tilt-dependent manner. In the case with more than 20 posterior pelvic tilt, available external rotation extended beyond required range with the cup anteversion of 20. Decreasing cup anteversion improved external rotation, however, internal rotation decreased simultaneously. In the case with posterior pelvic tilt more than 20, only cup anteversion with 0 or 10 satisfied the required range of motion. A + 4 mm horizontal offset improved external rotation by 10 with delaying bony impingement. Interpretation More than 20 of posterior pelvic tilt may cause anterior instability and diminish the optimal range of cup version. Increasing the femoral offset improved external rotation without reducing internal rotation.

AB - Background Anterior dislocation is one of the concerns of patients with posterior pelvic tilt undergoing total hip arthroplasty. This study aimed to evaluate the magnitude of posterior pelvic tilt constituting a risk for anterior dislocation by measuring the range of motion until impingement and dislocation under various pelvic tilt. Methods Using a jig mounted prosthetic hip model, the ranges of external rotation at extension and internal rotation at flexion until reaching dislocation were tested. The site of impingement prior to dislocation was also recorded. Posterior pelvic tilt and the cup version were changed with 10 increments from 0 to 40 and from 10 retroversion to 30 anteversion, respectively. Effects of increasing femoral offset were also tested. We defined a required range of motion as having 30 external rotation at extension and 40 internal rotation at 90 flexion. Findings External rotation decreased in a posterior pelvic tilt-dependent manner. In the case with more than 20 posterior pelvic tilt, available external rotation extended beyond required range with the cup anteversion of 20. Decreasing cup anteversion improved external rotation, however, internal rotation decreased simultaneously. In the case with posterior pelvic tilt more than 20, only cup anteversion with 0 or 10 satisfied the required range of motion. A + 4 mm horizontal offset improved external rotation by 10 with delaying bony impingement. Interpretation More than 20 of posterior pelvic tilt may cause anterior instability and diminish the optimal range of cup version. Increasing the femoral offset improved external rotation without reducing internal rotation.

UR - http://www.scopus.com/inward/record.url?scp=84875754757&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875754757&partnerID=8YFLogxK

U2 - 10.1016/j.clinbiomech.2012.12.011

DO - 10.1016/j.clinbiomech.2012.12.011

M3 - Article

VL - 28

SP - 178

EP - 181

JO - Clinical Biomechanics

JF - Clinical Biomechanics

SN - 0268-0033

IS - 2

ER -