Enzyme-linked immunosorbent assay by enhanced chemiluminescence detection for the standardization of estrogenic miroestrol in Pueraria candollei Graham ex Benth

Gorawit Yusakul, Orapin Udomsin, Hiroyuki Tanaka, Satoshi Morimoto, Thaweesak Juengwatanatrakul, Waraporn Putalun

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Miroestrol (ME) is a potent phytoestrogen from the P. candollei tuberous root. It has been approved for use in clinical trials due to its beneficial effect on disorders associated with estrogen deficiency. To ensure medical efficacy and safety, high performance analytical methods for ME analysis are required to standardize products from the P. candollei root. An enhanced chemiluminescence enzyme-linked immunosorbent assay (ECL-ELISA) was developed and validated using a polyclonal antibody against ME and a chemiluminescent system of luminol-H2O2-horseradish peroxidase-4-(1-imidazolyl) phenol. The ECL-ELISA system exhibited linearity over a concentration range of 0.31-10.00 ng mL-1, for which the relative standard variation (%RSD) was less than 10% for both intra- and interplate determinations. The ECL-ELISA is reliable for the determination of ME as reflected by the high recovery percentage (101.22-103.06%). As a comparative analysis, the ME content in each sample determined by ECL-ELISA was correlated with high coefficients of determination with colorimetric ELISA (R2 = 0.998) and high performance liquid chromatography (HPLC) (R2 = 0.998) methods. The ECL-ELISA method could be applied to all of the commercial products containing P. candollei root, when the products contain between 0.706 ± 0.046 and 13.123 ± 0.794 μg g-1 dry wt. of ME. This method is useful as a high performance analytical method for the quantity control of ME in raw materials and end products at both the research and industrial levels.

Original languageEnglish
Pages (from-to)568-575
Number of pages8
JournalLuminescence
Volume30
Issue number5
DOIs
Publication statusPublished - 2015

Fingerprint

Pueraria
Immunosorbents
Chemiluminescence
Luminescence
Standardization
Assays
Enzyme-Linked Immunosorbent Assay
Enzymes
Phytoestrogens
Luminol
High performance liquid chromatography
Horseradish Peroxidase
Phenol
miroestrol
Raw materials
Estrogens
High Pressure Liquid Chromatography
Clinical Trials
Safety
Recovery

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Chemistry (miscellaneous)

Cite this

Enzyme-linked immunosorbent assay by enhanced chemiluminescence detection for the standardization of estrogenic miroestrol in Pueraria candollei Graham ex Benth. / Yusakul, Gorawit; Udomsin, Orapin; Tanaka, Hiroyuki; Morimoto, Satoshi; Juengwatanatrakul, Thaweesak; Putalun, Waraporn.

In: Luminescence, Vol. 30, No. 5, 2015, p. 568-575.

Research output: Contribution to journalArticle

Yusakul, Gorawit ; Udomsin, Orapin ; Tanaka, Hiroyuki ; Morimoto, Satoshi ; Juengwatanatrakul, Thaweesak ; Putalun, Waraporn. / Enzyme-linked immunosorbent assay by enhanced chemiluminescence detection for the standardization of estrogenic miroestrol in Pueraria candollei Graham ex Benth. In: Luminescence. 2015 ; Vol. 30, No. 5. pp. 568-575.
@article{af54daab4d5247749512600589a5136a,
title = "Enzyme-linked immunosorbent assay by enhanced chemiluminescence detection for the standardization of estrogenic miroestrol in Pueraria candollei Graham ex Benth",
abstract = "Miroestrol (ME) is a potent phytoestrogen from the P. candollei tuberous root. It has been approved for use in clinical trials due to its beneficial effect on disorders associated with estrogen deficiency. To ensure medical efficacy and safety, high performance analytical methods for ME analysis are required to standardize products from the P. candollei root. An enhanced chemiluminescence enzyme-linked immunosorbent assay (ECL-ELISA) was developed and validated using a polyclonal antibody against ME and a chemiluminescent system of luminol-H2O2-horseradish peroxidase-4-(1-imidazolyl) phenol. The ECL-ELISA system exhibited linearity over a concentration range of 0.31-10.00 ng mL-1, for which the relative standard variation ({\%}RSD) was less than 10{\%} for both intra- and interplate determinations. The ECL-ELISA is reliable for the determination of ME as reflected by the high recovery percentage (101.22-103.06{\%}). As a comparative analysis, the ME content in each sample determined by ECL-ELISA was correlated with high coefficients of determination with colorimetric ELISA (R2 = 0.998) and high performance liquid chromatography (HPLC) (R2 = 0.998) methods. The ECL-ELISA method could be applied to all of the commercial products containing P. candollei root, when the products contain between 0.706 ± 0.046 and 13.123 ± 0.794 μg g-1 dry wt. of ME. This method is useful as a high performance analytical method for the quantity control of ME in raw materials and end products at both the research and industrial levels.",
author = "Gorawit Yusakul and Orapin Udomsin and Hiroyuki Tanaka and Satoshi Morimoto and Thaweesak Juengwatanatrakul and Waraporn Putalun",
year = "2015",
doi = "10.1002/bio.2787",
language = "English",
volume = "30",
pages = "568--575",
journal = "Luminescence",
issn = "1522-7235",
publisher = "John Wiley and Sons Ltd",
number = "5",

}

TY - JOUR

T1 - Enzyme-linked immunosorbent assay by enhanced chemiluminescence detection for the standardization of estrogenic miroestrol in Pueraria candollei Graham ex Benth

AU - Yusakul, Gorawit

AU - Udomsin, Orapin

AU - Tanaka, Hiroyuki

AU - Morimoto, Satoshi

AU - Juengwatanatrakul, Thaweesak

AU - Putalun, Waraporn

PY - 2015

Y1 - 2015

N2 - Miroestrol (ME) is a potent phytoestrogen from the P. candollei tuberous root. It has been approved for use in clinical trials due to its beneficial effect on disorders associated with estrogen deficiency. To ensure medical efficacy and safety, high performance analytical methods for ME analysis are required to standardize products from the P. candollei root. An enhanced chemiluminescence enzyme-linked immunosorbent assay (ECL-ELISA) was developed and validated using a polyclonal antibody against ME and a chemiluminescent system of luminol-H2O2-horseradish peroxidase-4-(1-imidazolyl) phenol. The ECL-ELISA system exhibited linearity over a concentration range of 0.31-10.00 ng mL-1, for which the relative standard variation (%RSD) was less than 10% for both intra- and interplate determinations. The ECL-ELISA is reliable for the determination of ME as reflected by the high recovery percentage (101.22-103.06%). As a comparative analysis, the ME content in each sample determined by ECL-ELISA was correlated with high coefficients of determination with colorimetric ELISA (R2 = 0.998) and high performance liquid chromatography (HPLC) (R2 = 0.998) methods. The ECL-ELISA method could be applied to all of the commercial products containing P. candollei root, when the products contain between 0.706 ± 0.046 and 13.123 ± 0.794 μg g-1 dry wt. of ME. This method is useful as a high performance analytical method for the quantity control of ME in raw materials and end products at both the research and industrial levels.

AB - Miroestrol (ME) is a potent phytoestrogen from the P. candollei tuberous root. It has been approved for use in clinical trials due to its beneficial effect on disorders associated with estrogen deficiency. To ensure medical efficacy and safety, high performance analytical methods for ME analysis are required to standardize products from the P. candollei root. An enhanced chemiluminescence enzyme-linked immunosorbent assay (ECL-ELISA) was developed and validated using a polyclonal antibody against ME and a chemiluminescent system of luminol-H2O2-horseradish peroxidase-4-(1-imidazolyl) phenol. The ECL-ELISA system exhibited linearity over a concentration range of 0.31-10.00 ng mL-1, for which the relative standard variation (%RSD) was less than 10% for both intra- and interplate determinations. The ECL-ELISA is reliable for the determination of ME as reflected by the high recovery percentage (101.22-103.06%). As a comparative analysis, the ME content in each sample determined by ECL-ELISA was correlated with high coefficients of determination with colorimetric ELISA (R2 = 0.998) and high performance liquid chromatography (HPLC) (R2 = 0.998) methods. The ECL-ELISA method could be applied to all of the commercial products containing P. candollei root, when the products contain between 0.706 ± 0.046 and 13.123 ± 0.794 μg g-1 dry wt. of ME. This method is useful as a high performance analytical method for the quantity control of ME in raw materials and end products at both the research and industrial levels.

UR - http://www.scopus.com/inward/record.url?scp=84939783448&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84939783448&partnerID=8YFLogxK

U2 - 10.1002/bio.2787

DO - 10.1002/bio.2787

M3 - Article

VL - 30

SP - 568

EP - 575

JO - Luminescence

JF - Luminescence

SN - 1522-7235

IS - 5

ER -