Estimation of AC losses in the windings of a 1 MVA HTS transformer

Yuzo Fukuda, Kazuhiro Kajikawa, Masataka Iwakuma, Kazuo Funaki, Takaaki Bohno, Akira Tomioka, Masayuki Konno, Yujiro Yagi, Hiroshi Maruyama, Shigeru Yoshida, Katsuya Tsutsumi, Hidemi Hayashi, Kazuo Honda

Research output: Contribution to journalArticle

Abstract

AC losses in the windings of an HTS transformer are important to design its system. We fabricated an HTS transformer and measured the AC losses. We estimated the AC losses by following procedures. First, we calculated the magnetic field distribution in each turn. Secondary, we estimated the losses of each turn referring to AC losses in the strand. Finally, we can calculate the AC loss in the windings by the total sum of the losses in each turn. We compared the calculated result with observed one, and discussed the validity of the proposed method.

Original languageEnglish
Pages (from-to)31-36
Number of pages6
JournalResearch Reports on Information Science and Electrical Engineering of Kyushu University
Volume8
Issue number1
Publication statusPublished - Mar 1 2003

Fingerprint

Magnetic fields

All Science Journal Classification (ASJC) codes

  • Computer Science(all)
  • Electrical and Electronic Engineering

Cite this

Estimation of AC losses in the windings of a 1 MVA HTS transformer. / Fukuda, Yuzo; Kajikawa, Kazuhiro; Iwakuma, Masataka; Funaki, Kazuo; Bohno, Takaaki; Tomioka, Akira; Konno, Masayuki; Yagi, Yujiro; Maruyama, Hiroshi; Yoshida, Shigeru; Tsutsumi, Katsuya; Hayashi, Hidemi; Honda, Kazuo.

In: Research Reports on Information Science and Electrical Engineering of Kyushu University, Vol. 8, No. 1, 01.03.2003, p. 31-36.

Research output: Contribution to journalArticle

Fukuda, Y, Kajikawa, K, Iwakuma, M, Funaki, K, Bohno, T, Tomioka, A, Konno, M, Yagi, Y, Maruyama, H, Yoshida, S, Tsutsumi, K, Hayashi, H & Honda, K 2003, 'Estimation of AC losses in the windings of a 1 MVA HTS transformer', Research Reports on Information Science and Electrical Engineering of Kyushu University, vol. 8, no. 1, pp. 31-36.
Fukuda, Yuzo ; Kajikawa, Kazuhiro ; Iwakuma, Masataka ; Funaki, Kazuo ; Bohno, Takaaki ; Tomioka, Akira ; Konno, Masayuki ; Yagi, Yujiro ; Maruyama, Hiroshi ; Yoshida, Shigeru ; Tsutsumi, Katsuya ; Hayashi, Hidemi ; Honda, Kazuo. / Estimation of AC losses in the windings of a 1 MVA HTS transformer. In: Research Reports on Information Science and Electrical Engineering of Kyushu University. 2003 ; Vol. 8, No. 1. pp. 31-36.
@article{90cc2e7e8cfd413bb633d4f53e6a4f2b,
title = "Estimation of AC losses in the windings of a 1 MVA HTS transformer",
abstract = "AC losses in the windings of an HTS transformer are important to design its system. We fabricated an HTS transformer and measured the AC losses. We estimated the AC losses by following procedures. First, we calculated the magnetic field distribution in each turn. Secondary, we estimated the losses of each turn referring to AC losses in the strand. Finally, we can calculate the AC loss in the windings by the total sum of the losses in each turn. We compared the calculated result with observed one, and discussed the validity of the proposed method.",
author = "Yuzo Fukuda and Kazuhiro Kajikawa and Masataka Iwakuma and Kazuo Funaki and Takaaki Bohno and Akira Tomioka and Masayuki Konno and Yujiro Yagi and Hiroshi Maruyama and Shigeru Yoshida and Katsuya Tsutsumi and Hidemi Hayashi and Kazuo Honda",
year = "2003",
month = "3",
day = "1",
language = "English",
volume = "8",
pages = "31--36",
journal = "Research Reports on Information Science and Electrical Engineering of Kyushu University",
issn = "1342-3819",
publisher = "Kyushu University, Faculty of Science",
number = "1",

}

TY - JOUR

T1 - Estimation of AC losses in the windings of a 1 MVA HTS transformer

AU - Fukuda, Yuzo

AU - Kajikawa, Kazuhiro

AU - Iwakuma, Masataka

AU - Funaki, Kazuo

AU - Bohno, Takaaki

AU - Tomioka, Akira

AU - Konno, Masayuki

AU - Yagi, Yujiro

AU - Maruyama, Hiroshi

AU - Yoshida, Shigeru

AU - Tsutsumi, Katsuya

AU - Hayashi, Hidemi

AU - Honda, Kazuo

PY - 2003/3/1

Y1 - 2003/3/1

N2 - AC losses in the windings of an HTS transformer are important to design its system. We fabricated an HTS transformer and measured the AC losses. We estimated the AC losses by following procedures. First, we calculated the magnetic field distribution in each turn. Secondary, we estimated the losses of each turn referring to AC losses in the strand. Finally, we can calculate the AC loss in the windings by the total sum of the losses in each turn. We compared the calculated result with observed one, and discussed the validity of the proposed method.

AB - AC losses in the windings of an HTS transformer are important to design its system. We fabricated an HTS transformer and measured the AC losses. We estimated the AC losses by following procedures. First, we calculated the magnetic field distribution in each turn. Secondary, we estimated the losses of each turn referring to AC losses in the strand. Finally, we can calculate the AC loss in the windings by the total sum of the losses in each turn. We compared the calculated result with observed one, and discussed the validity of the proposed method.

UR - http://www.scopus.com/inward/record.url?scp=0037835682&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037835682&partnerID=8YFLogxK

M3 - Article

VL - 8

SP - 31

EP - 36

JO - Research Reports on Information Science and Electrical Engineering of Kyushu University

JF - Research Reports on Information Science and Electrical Engineering of Kyushu University

SN - 1342-3819

IS - 1

ER -