Estimation of equivalent diffusion length for desiccator geometries applicable to formaldehyde emission test

Yujin Kang, Yutaro Kyuma, Sungjun Yoo, Kazuki Takenouchi, Hitomi Yoshida, Shin ichi Tanabe, Kazuhide Ito

Research output: Contribution to journalArticle

Abstract

In order to estimate formaldehyde emission rate from building materials, desiccator method (JIS A 1460) has been widely used as an alternative of small test chamber method based on JIS A 1901. Recently, market supply of desiccator specified by JIS R 3503 was canceled and there is no prospect of future production, and hence it is necessary to investigate the various desiccators on market and to clarify their performance related formaldehyde emission test. This paper reports numerical analysis by reproducing diffusion phenomenon in desiccators appropriate for the formaldehyde emission test.

Original languageEnglish
Pages (from-to)883-889
Number of pages7
JournalJournal of Environmental Engineering (Japan)
Volume83
Issue number753
DOIs
Publication statusPublished - Nov 1 2018

Fingerprint

Formaldehyde
Geometry
Numerical analysis

All Science Journal Classification (ASJC) codes

  • Environmental Engineering

Cite this

Estimation of equivalent diffusion length for desiccator geometries applicable to formaldehyde emission test. / Kang, Yujin; Kyuma, Yutaro; Yoo, Sungjun; Takenouchi, Kazuki; Yoshida, Hitomi; Tanabe, Shin ichi; Ito, Kazuhide.

In: Journal of Environmental Engineering (Japan), Vol. 83, No. 753, 01.11.2018, p. 883-889.

Research output: Contribution to journalArticle

Kang, Yujin ; Kyuma, Yutaro ; Yoo, Sungjun ; Takenouchi, Kazuki ; Yoshida, Hitomi ; Tanabe, Shin ichi ; Ito, Kazuhide. / Estimation of equivalent diffusion length for desiccator geometries applicable to formaldehyde emission test. In: Journal of Environmental Engineering (Japan). 2018 ; Vol. 83, No. 753. pp. 883-889.
@article{209f6d4facae42f48de0752f6964ef1e,
title = "Estimation of equivalent diffusion length for desiccator geometries applicable to formaldehyde emission test",
abstract = "In order to estimate formaldehyde emission rate from building materials, desiccator method (JIS A 1460) has been widely used as an alternative of small test chamber method based on JIS A 1901. Recently, market supply of desiccator specified by JIS R 3503 was canceled and there is no prospect of future production, and hence it is necessary to investigate the various desiccators on market and to clarify their performance related formaldehyde emission test. This paper reports numerical analysis by reproducing diffusion phenomenon in desiccators appropriate for the formaldehyde emission test.",
author = "Yujin Kang and Yutaro Kyuma and Sungjun Yoo and Kazuki Takenouchi and Hitomi Yoshida and Tanabe, {Shin ichi} and Kazuhide Ito",
year = "2018",
month = "11",
day = "1",
doi = "10.3130/aije.83.883",
language = "English",
volume = "83",
pages = "883--889",
journal = "Journal of Environmental Engineering (Japan)",
issn = "1348-0685",
publisher = "Architectural Institute of Japan",
number = "753",

}

TY - JOUR

T1 - Estimation of equivalent diffusion length for desiccator geometries applicable to formaldehyde emission test

AU - Kang, Yujin

AU - Kyuma, Yutaro

AU - Yoo, Sungjun

AU - Takenouchi, Kazuki

AU - Yoshida, Hitomi

AU - Tanabe, Shin ichi

AU - Ito, Kazuhide

PY - 2018/11/1

Y1 - 2018/11/1

N2 - In order to estimate formaldehyde emission rate from building materials, desiccator method (JIS A 1460) has been widely used as an alternative of small test chamber method based on JIS A 1901. Recently, market supply of desiccator specified by JIS R 3503 was canceled and there is no prospect of future production, and hence it is necessary to investigate the various desiccators on market and to clarify their performance related formaldehyde emission test. This paper reports numerical analysis by reproducing diffusion phenomenon in desiccators appropriate for the formaldehyde emission test.

AB - In order to estimate formaldehyde emission rate from building materials, desiccator method (JIS A 1460) has been widely used as an alternative of small test chamber method based on JIS A 1901. Recently, market supply of desiccator specified by JIS R 3503 was canceled and there is no prospect of future production, and hence it is necessary to investigate the various desiccators on market and to clarify their performance related formaldehyde emission test. This paper reports numerical analysis by reproducing diffusion phenomenon in desiccators appropriate for the formaldehyde emission test.

UR - http://www.scopus.com/inward/record.url?scp=85057819628&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057819628&partnerID=8YFLogxK

U2 - 10.3130/aije.83.883

DO - 10.3130/aije.83.883

M3 - Article

VL - 83

SP - 883

EP - 889

JO - Journal of Environmental Engineering (Japan)

JF - Journal of Environmental Engineering (Japan)

SN - 1348-0685

IS - 753

ER -