TY - JOUR
T1 - Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators
AU - Anai, Shigeo
AU - Arimura, Hidetaka
AU - Nakamura, Katsumasa
AU - Araki, Fujio
AU - Matsuki, Takaomi
AU - Yoshikawa, Hideki
AU - Yoshidome, Satoshi
AU - Shioyama, Yoshiyuki
AU - Honda, Hiroshi
AU - Ikeda, Nobuo
PY - 2011/7
Y1 - 2011/7
N2 - The X-ray source or focal radiation is one of the factors that can degrade the conformal field edge in stereotactic body radiotherapy. For that reason, it is very important to estimate the total focal radiation profiles of linear accelerators, which consists of X-ray focal-spot radiation and extra-focal radiation profiles. Our purpose in this study was to propose an experimental method for estimating the focal-spot and extra-focal radiation profiles of linear accelerators based on triple Gaussian functions. We measured the total X-ray focal radiation profiles of the accelerators by moving a slit in conjunction with a photon field p-type silicon diode. The slit width was changed so that the extra-focal radiation could be optimally included in the total focal radiation. The total focal radiation profiles of an accelerator at 4-MV and 10-MV energies were approximated with a combination of triple Gaussian functions, which correspond to the focal-spot radiation, extra-focal radiation, and radiation transmitted through the slit assembly. As a result, the ratios of the Gaussian peak value of the extra-focal radiation to that of the focal spot for 4 and 10 MV were 0.077 and 0.159, respectively. The peak widths of the focal-spot and extra-focal radiation profiles were 0.57 and 25.0 mm for 4 MV, respectively, and 0.60 and 22.0 mm for 10 MV, respectively. We concluded that the proposed focal radiation profile model based on the triple Gaussian functions may be feasible for estimating the X-ray focal-spot and extra-focal radiation profiles.
AB - The X-ray source or focal radiation is one of the factors that can degrade the conformal field edge in stereotactic body radiotherapy. For that reason, it is very important to estimate the total focal radiation profiles of linear accelerators, which consists of X-ray focal-spot radiation and extra-focal radiation profiles. Our purpose in this study was to propose an experimental method for estimating the focal-spot and extra-focal radiation profiles of linear accelerators based on triple Gaussian functions. We measured the total X-ray focal radiation profiles of the accelerators by moving a slit in conjunction with a photon field p-type silicon diode. The slit width was changed so that the extra-focal radiation could be optimally included in the total focal radiation. The total focal radiation profiles of an accelerator at 4-MV and 10-MV energies were approximated with a combination of triple Gaussian functions, which correspond to the focal-spot radiation, extra-focal radiation, and radiation transmitted through the slit assembly. As a result, the ratios of the Gaussian peak value of the extra-focal radiation to that of the focal spot for 4 and 10 MV were 0.077 and 0.159, respectively. The peak widths of the focal-spot and extra-focal radiation profiles were 0.57 and 25.0 mm for 4 MV, respectively, and 0.60 and 22.0 mm for 10 MV, respectively. We concluded that the proposed focal radiation profile model based on the triple Gaussian functions may be feasible for estimating the X-ray focal-spot and extra-focal radiation profiles.
UR - http://www.scopus.com/inward/record.url?scp=79960446040&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79960446040&partnerID=8YFLogxK
U2 - 10.1007/s12194-011-0118-1
DO - 10.1007/s12194-011-0118-1
M3 - Article
C2 - 21431890
AN - SCOPUS:79960446040
VL - 4
SP - 173
EP - 179
JO - Radiological Physics and Technology
JF - Radiological Physics and Technology
SN - 1865-0333
IS - 2
ER -