Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology

Takaya Sasaki, Nobuo Tsuboi, Yusuke Okabayashi, Kotaro Haruhara, Go Kanzaki, Kentaro Koike, Akimitsu Kobayashi, Izumi Yamamoto, Sho Takahashi, Toshiharu Ninomiya, Akira Shimizu, Andrew D. Rule, John F. Bertram, Takashi Yokoo

Research output: Contribution to journalArticle

Abstract

Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced and unenhanced CT examinations were randomly assigned to development and validation groups. The enhanced CT-measured arterial phase and the venous phase images of kidneys were regarded as the true values for cortical volume and parenchymal volume, respectively. Linear multiple regression analysis was used to create models for estimating cortical volume using explanatory variables including unenhanced CT-measured parenchymal volume. Nephron number was determined as the product of cortical volume and the glomerular density in biopsies of donors. Five equations for estimating cortical volume were created and verified. In donors, estimated nephron number by unenhanced CT was consistent with that by enhanced CT, with minimal errors in all models (636–655 ± 210–219 vs. 648 ± 224 × 103/kidney). Clinical characteristics combined with parenchymal volume did not improve the equation over parenchymal volume alone. These results support the feasibility of estimating nephron number by a combination of unenhanced CT and biopsy-based stereology, with a possible application for renal disease patients who are often not suitable for contrast media.

Original languageEnglish
Article number14400
JournalScientific reports
Volume9
Issue number1
DOIs
Publication statusPublished - Dec 1 2019

Fingerprint

Nephrons
Tomography
Biopsy
Kidney
Tissue Donors
Living Donors
Contrast Media
Linear Models
Regression Analysis

All Science Journal Classification (ASJC) codes

  • General

Cite this

Sasaki, T., Tsuboi, N., Okabayashi, Y., Haruhara, K., Kanzaki, G., Koike, K., ... Yokoo, T. (2019). Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology. Scientific reports, 9(1), [14400]. https://doi.org/10.1038/s41598-019-50529-x

Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology. / Sasaki, Takaya; Tsuboi, Nobuo; Okabayashi, Yusuke; Haruhara, Kotaro; Kanzaki, Go; Koike, Kentaro; Kobayashi, Akimitsu; Yamamoto, Izumi; Takahashi, Sho; Ninomiya, Toshiharu; Shimizu, Akira; Rule, Andrew D.; Bertram, John F.; Yokoo, Takashi.

In: Scientific reports, Vol. 9, No. 1, 14400, 01.12.2019.

Research output: Contribution to journalArticle

Sasaki, T, Tsuboi, N, Okabayashi, Y, Haruhara, K, Kanzaki, G, Koike, K, Kobayashi, A, Yamamoto, I, Takahashi, S, Ninomiya, T, Shimizu, A, Rule, AD, Bertram, JF & Yokoo, T 2019, 'Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology', Scientific reports, vol. 9, no. 1, 14400. https://doi.org/10.1038/s41598-019-50529-x
Sasaki, Takaya ; Tsuboi, Nobuo ; Okabayashi, Yusuke ; Haruhara, Kotaro ; Kanzaki, Go ; Koike, Kentaro ; Kobayashi, Akimitsu ; Yamamoto, Izumi ; Takahashi, Sho ; Ninomiya, Toshiharu ; Shimizu, Akira ; Rule, Andrew D. ; Bertram, John F. ; Yokoo, Takashi. / Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology. In: Scientific reports. 2019 ; Vol. 9, No. 1.
@article{18afc0ecc88045d3982aaec69642e3ce,
title = "Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology",
abstract = "Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced and unenhanced CT examinations were randomly assigned to development and validation groups. The enhanced CT-measured arterial phase and the venous phase images of kidneys were regarded as the true values for cortical volume and parenchymal volume, respectively. Linear multiple regression analysis was used to create models for estimating cortical volume using explanatory variables including unenhanced CT-measured parenchymal volume. Nephron number was determined as the product of cortical volume and the glomerular density in biopsies of donors. Five equations for estimating cortical volume were created and verified. In donors, estimated nephron number by unenhanced CT was consistent with that by enhanced CT, with minimal errors in all models (636–655 ± 210–219 vs. 648 ± 224 × 103/kidney). Clinical characteristics combined with parenchymal volume did not improve the equation over parenchymal volume alone. These results support the feasibility of estimating nephron number by a combination of unenhanced CT and biopsy-based stereology, with a possible application for renal disease patients who are often not suitable for contrast media.",
author = "Takaya Sasaki and Nobuo Tsuboi and Yusuke Okabayashi and Kotaro Haruhara and Go Kanzaki and Kentaro Koike and Akimitsu Kobayashi and Izumi Yamamoto and Sho Takahashi and Toshiharu Ninomiya and Akira Shimizu and Rule, {Andrew D.} and Bertram, {John F.} and Takashi Yokoo",
year = "2019",
month = "12",
day = "1",
doi = "10.1038/s41598-019-50529-x",
language = "English",
volume = "9",
journal = "Scientific Reports",
issn = "2045-2322",
publisher = "Nature Publishing Group",
number = "1",

}

TY - JOUR

T1 - Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology

AU - Sasaki, Takaya

AU - Tsuboi, Nobuo

AU - Okabayashi, Yusuke

AU - Haruhara, Kotaro

AU - Kanzaki, Go

AU - Koike, Kentaro

AU - Kobayashi, Akimitsu

AU - Yamamoto, Izumi

AU - Takahashi, Sho

AU - Ninomiya, Toshiharu

AU - Shimizu, Akira

AU - Rule, Andrew D.

AU - Bertram, John F.

AU - Yokoo, Takashi

PY - 2019/12/1

Y1 - 2019/12/1

N2 - Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced and unenhanced CT examinations were randomly assigned to development and validation groups. The enhanced CT-measured arterial phase and the venous phase images of kidneys were regarded as the true values for cortical volume and parenchymal volume, respectively. Linear multiple regression analysis was used to create models for estimating cortical volume using explanatory variables including unenhanced CT-measured parenchymal volume. Nephron number was determined as the product of cortical volume and the glomerular density in biopsies of donors. Five equations for estimating cortical volume were created and verified. In donors, estimated nephron number by unenhanced CT was consistent with that by enhanced CT, with minimal errors in all models (636–655 ± 210–219 vs. 648 ± 224 × 103/kidney). Clinical characteristics combined with parenchymal volume did not improve the equation over parenchymal volume alone. These results support the feasibility of estimating nephron number by a combination of unenhanced CT and biopsy-based stereology, with a possible application for renal disease patients who are often not suitable for contrast media.

AB - Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced and unenhanced CT examinations were randomly assigned to development and validation groups. The enhanced CT-measured arterial phase and the venous phase images of kidneys were regarded as the true values for cortical volume and parenchymal volume, respectively. Linear multiple regression analysis was used to create models for estimating cortical volume using explanatory variables including unenhanced CT-measured parenchymal volume. Nephron number was determined as the product of cortical volume and the glomerular density in biopsies of donors. Five equations for estimating cortical volume were created and verified. In donors, estimated nephron number by unenhanced CT was consistent with that by enhanced CT, with minimal errors in all models (636–655 ± 210–219 vs. 648 ± 224 × 103/kidney). Clinical characteristics combined with parenchymal volume did not improve the equation over parenchymal volume alone. These results support the feasibility of estimating nephron number by a combination of unenhanced CT and biopsy-based stereology, with a possible application for renal disease patients who are often not suitable for contrast media.

UR - http://www.scopus.com/inward/record.url?scp=85073072869&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85073072869&partnerID=8YFLogxK

U2 - 10.1038/s41598-019-50529-x

DO - 10.1038/s41598-019-50529-x

M3 - Article

C2 - 31591408

AN - SCOPUS:85073072869

VL - 9

JO - Scientific Reports

JF - Scientific Reports

SN - 2045-2322

IS - 1

M1 - 14400