Evaluation of the firmness measurement of fruit by using a non-contact ultrasonic technique

Sangdae Lee, Masumi Hasegawa, Ki Bok Kim, Jeong Gil Park, Byoung Kwan Cho

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

In this study, we investigated the feasibility of using a novel non-contact ultrasonic technique to measure fruit firmness. The intensity of the reflected ultrasonic signal that bounces back from the fruit surface is dependent on the firmness of the fruit surface. However, differences in fruit size cause the reflected intensity to change with the distance separating the non-contact ultrasonic transducer and fruit surface. Therefore, it is necessary to eliminate the effect of fruit size on signal intensity to accurately predict fruit firmness when using a reflected ultrasonic signal. In this study, we developed and evaluated distance correction factors, which may reduce the size effects of fruit on the reflected ultrasonic signal. The distance correction factors were proposed using a combination of ultrasonic parameters obtained from the first and second reflected ultrasonic signals in the time and frequency domain. Fruit firmness parameters, such as bioyield strength and apparent elastic modulus, were measured and correlated with the distance corrected non-contact ultrasonic parameters. Multiple linear regression models to predict fruit firmness using ultrasonic parameters were assessed. The results demonstrated the potential utility of the distance corrected non-contact ultrasonic technique for the non-destructive measurement of fruit firmness.

Original languageEnglish
Pages (from-to)103-108
Number of pages6
JournalJournal of the Faculty of Agriculture, Kyushu University
Volume58
Issue number1
Publication statusPublished - Feb 1 2013

Fingerprint

Ultrasonics
firmness
Fruit
ultrasonics
fruits
methodology
Linear Models
Elastic Modulus
Transducers
modulus of elasticity

All Science Journal Classification (ASJC) codes

  • Biotechnology
  • Agronomy and Crop Science

Cite this

Evaluation of the firmness measurement of fruit by using a non-contact ultrasonic technique. / Lee, Sangdae; Hasegawa, Masumi; Kim, Ki Bok; Park, Jeong Gil; Cho, Byoung Kwan.

In: Journal of the Faculty of Agriculture, Kyushu University, Vol. 58, No. 1, 01.02.2013, p. 103-108.

Research output: Contribution to journalArticle

@article{09869bdf1eed407481b1787c4ce3efc6,
title = "Evaluation of the firmness measurement of fruit by using a non-contact ultrasonic technique",
abstract = "In this study, we investigated the feasibility of using a novel non-contact ultrasonic technique to measure fruit firmness. The intensity of the reflected ultrasonic signal that bounces back from the fruit surface is dependent on the firmness of the fruit surface. However, differences in fruit size cause the reflected intensity to change with the distance separating the non-contact ultrasonic transducer and fruit surface. Therefore, it is necessary to eliminate the effect of fruit size on signal intensity to accurately predict fruit firmness when using a reflected ultrasonic signal. In this study, we developed and evaluated distance correction factors, which may reduce the size effects of fruit on the reflected ultrasonic signal. The distance correction factors were proposed using a combination of ultrasonic parameters obtained from the first and second reflected ultrasonic signals in the time and frequency domain. Fruit firmness parameters, such as bioyield strength and apparent elastic modulus, were measured and correlated with the distance corrected non-contact ultrasonic parameters. Multiple linear regression models to predict fruit firmness using ultrasonic parameters were assessed. The results demonstrated the potential utility of the distance corrected non-contact ultrasonic technique for the non-destructive measurement of fruit firmness.",
author = "Sangdae Lee and Masumi Hasegawa and Kim, {Ki Bok} and Park, {Jeong Gil} and Cho, {Byoung Kwan}",
year = "2013",
month = "2",
day = "1",
language = "English",
volume = "58",
pages = "103--108",
journal = "Journal of the Faculty of Agriculture, Kyushu University",
issn = "0023-6152",
publisher = "Faculty of Agriculture, Kyushu University",
number = "1",

}

TY - JOUR

T1 - Evaluation of the firmness measurement of fruit by using a non-contact ultrasonic technique

AU - Lee, Sangdae

AU - Hasegawa, Masumi

AU - Kim, Ki Bok

AU - Park, Jeong Gil

AU - Cho, Byoung Kwan

PY - 2013/2/1

Y1 - 2013/2/1

N2 - In this study, we investigated the feasibility of using a novel non-contact ultrasonic technique to measure fruit firmness. The intensity of the reflected ultrasonic signal that bounces back from the fruit surface is dependent on the firmness of the fruit surface. However, differences in fruit size cause the reflected intensity to change with the distance separating the non-contact ultrasonic transducer and fruit surface. Therefore, it is necessary to eliminate the effect of fruit size on signal intensity to accurately predict fruit firmness when using a reflected ultrasonic signal. In this study, we developed and evaluated distance correction factors, which may reduce the size effects of fruit on the reflected ultrasonic signal. The distance correction factors were proposed using a combination of ultrasonic parameters obtained from the first and second reflected ultrasonic signals in the time and frequency domain. Fruit firmness parameters, such as bioyield strength and apparent elastic modulus, were measured and correlated with the distance corrected non-contact ultrasonic parameters. Multiple linear regression models to predict fruit firmness using ultrasonic parameters were assessed. The results demonstrated the potential utility of the distance corrected non-contact ultrasonic technique for the non-destructive measurement of fruit firmness.

AB - In this study, we investigated the feasibility of using a novel non-contact ultrasonic technique to measure fruit firmness. The intensity of the reflected ultrasonic signal that bounces back from the fruit surface is dependent on the firmness of the fruit surface. However, differences in fruit size cause the reflected intensity to change with the distance separating the non-contact ultrasonic transducer and fruit surface. Therefore, it is necessary to eliminate the effect of fruit size on signal intensity to accurately predict fruit firmness when using a reflected ultrasonic signal. In this study, we developed and evaluated distance correction factors, which may reduce the size effects of fruit on the reflected ultrasonic signal. The distance correction factors were proposed using a combination of ultrasonic parameters obtained from the first and second reflected ultrasonic signals in the time and frequency domain. Fruit firmness parameters, such as bioyield strength and apparent elastic modulus, were measured and correlated with the distance corrected non-contact ultrasonic parameters. Multiple linear regression models to predict fruit firmness using ultrasonic parameters were assessed. The results demonstrated the potential utility of the distance corrected non-contact ultrasonic technique for the non-destructive measurement of fruit firmness.

UR - http://www.scopus.com/inward/record.url?scp=84874869690&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874869690&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84874869690

VL - 58

SP - 103

EP - 108

JO - Journal of the Faculty of Agriculture, Kyushu University

JF - Journal of the Faculty of Agriculture, Kyushu University

SN - 0023-6152

IS - 1