Evaluation of the optimal exposure settings for occlusal photography with digital cameras

Yu Sugawara, Kan Saito, Masaharu Futaki, Masahiro Naruse, Mariko Ono, Ryoko Hino, Yuta Chiba, Makiko Arakaki, Aya Yamada, Satoshi Fukumoto

Research output: Contribution to journalArticle

Abstract

Background and objective: Recently, there have been produced several kinds of camera systems, lighting devices and image processing programs. The intraoral photographs are periodically required in pediatric dentistry, since the oral environment of children changes rapidly and dramatically because of disease, growth, and tooth eruption. However, the suitable settings for intraoral digital imaging have not yet been reported. In this study, single-lens reflex and mirrorless cameras were used with a ring flash, ring light emitting diode (LED), or standard fluorescent lamp to determine the optimal exposure parameters for occlusal photography. Materials and methods: Fifty-six dentists evaluated images of a discolored nonvital central incisor and first molar with recurrent caries and stained fissures clipped from a low-magnification photograph of the adult maxillary occlusal surface reflected in a mirror by using various F-numbers (representing aperture), shutter speeds, and International Organization for Standardization (ISO) numbers (representing light sensitivity). Results: The results showed that F-numbers between 5.6 and 10, shutter speeds faster than 1/30s, and ISO 800 produce the best occlusal images when a 60 mm f/2.8 Macro lens is used. Better images are obtained with ring LED than with ring flash. Furthermore, ISO 3200 is required for low-magnification photography in natural light. Finally, intraoral digital images should be captured under low magnification, because tilted or deflected images can be adjusted by using imaging software.

Original languageEnglish
Pages (from-to)89-96
Number of pages8
Journalpediatric dental journal
Volume24
Issue number2
DOIs
Publication statusPublished - Jan 1 2014
Externally publishedYes

Fingerprint

Photography
Light
Lenses
Tooth Eruption
Pediatric Dentistry
Photophobia
Incisor
Dentists
Lighting
Reflex
Software
Equipment and Supplies
Growth

All Science Journal Classification (ASJC) codes

  • Pediatrics, Perinatology, and Child Health
  • Dentistry (miscellaneous)

Cite this

Evaluation of the optimal exposure settings for occlusal photography with digital cameras. / Sugawara, Yu; Saito, Kan; Futaki, Masaharu; Naruse, Masahiro; Ono, Mariko; Hino, Ryoko; Chiba, Yuta; Arakaki, Makiko; Yamada, Aya; Fukumoto, Satoshi.

In: pediatric dental journal, Vol. 24, No. 2, 01.01.2014, p. 89-96.

Research output: Contribution to journalArticle

Sugawara, Y, Saito, K, Futaki, M, Naruse, M, Ono, M, Hino, R, Chiba, Y, Arakaki, M, Yamada, A & Fukumoto, S 2014, 'Evaluation of the optimal exposure settings for occlusal photography with digital cameras', pediatric dental journal, vol. 24, no. 2, pp. 89-96. https://doi.org/10.1016/j.pdj.2014.04.002
Sugawara, Yu ; Saito, Kan ; Futaki, Masaharu ; Naruse, Masahiro ; Ono, Mariko ; Hino, Ryoko ; Chiba, Yuta ; Arakaki, Makiko ; Yamada, Aya ; Fukumoto, Satoshi. / Evaluation of the optimal exposure settings for occlusal photography with digital cameras. In: pediatric dental journal. 2014 ; Vol. 24, No. 2. pp. 89-96.
@article{6f02331545d041e0b63b778853e01f06,
title = "Evaluation of the optimal exposure settings for occlusal photography with digital cameras",
abstract = "Background and objective: Recently, there have been produced several kinds of camera systems, lighting devices and image processing programs. The intraoral photographs are periodically required in pediatric dentistry, since the oral environment of children changes rapidly and dramatically because of disease, growth, and tooth eruption. However, the suitable settings for intraoral digital imaging have not yet been reported. In this study, single-lens reflex and mirrorless cameras were used with a ring flash, ring light emitting diode (LED), or standard fluorescent lamp to determine the optimal exposure parameters for occlusal photography. Materials and methods: Fifty-six dentists evaluated images of a discolored nonvital central incisor and first molar with recurrent caries and stained fissures clipped from a low-magnification photograph of the adult maxillary occlusal surface reflected in a mirror by using various F-numbers (representing aperture), shutter speeds, and International Organization for Standardization (ISO) numbers (representing light sensitivity). Results: The results showed that F-numbers between 5.6 and 10, shutter speeds faster than 1/30s, and ISO 800 produce the best occlusal images when a 60 mm f/2.8 Macro lens is used. Better images are obtained with ring LED than with ring flash. Furthermore, ISO 3200 is required for low-magnification photography in natural light. Finally, intraoral digital images should be captured under low magnification, because tilted or deflected images can be adjusted by using imaging software.",
author = "Yu Sugawara and Kan Saito and Masaharu Futaki and Masahiro Naruse and Mariko Ono and Ryoko Hino and Yuta Chiba and Makiko Arakaki and Aya Yamada and Satoshi Fukumoto",
year = "2014",
month = "1",
day = "1",
doi = "10.1016/j.pdj.2014.04.002",
language = "English",
volume = "24",
pages = "89--96",
journal = "Pediatric Dental Journal",
issn = "0917-2394",
publisher = "Elsevier BV",
number = "2",

}

TY - JOUR

T1 - Evaluation of the optimal exposure settings for occlusal photography with digital cameras

AU - Sugawara, Yu

AU - Saito, Kan

AU - Futaki, Masaharu

AU - Naruse, Masahiro

AU - Ono, Mariko

AU - Hino, Ryoko

AU - Chiba, Yuta

AU - Arakaki, Makiko

AU - Yamada, Aya

AU - Fukumoto, Satoshi

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Background and objective: Recently, there have been produced several kinds of camera systems, lighting devices and image processing programs. The intraoral photographs are periodically required in pediatric dentistry, since the oral environment of children changes rapidly and dramatically because of disease, growth, and tooth eruption. However, the suitable settings for intraoral digital imaging have not yet been reported. In this study, single-lens reflex and mirrorless cameras were used with a ring flash, ring light emitting diode (LED), or standard fluorescent lamp to determine the optimal exposure parameters for occlusal photography. Materials and methods: Fifty-six dentists evaluated images of a discolored nonvital central incisor and first molar with recurrent caries and stained fissures clipped from a low-magnification photograph of the adult maxillary occlusal surface reflected in a mirror by using various F-numbers (representing aperture), shutter speeds, and International Organization for Standardization (ISO) numbers (representing light sensitivity). Results: The results showed that F-numbers between 5.6 and 10, shutter speeds faster than 1/30s, and ISO 800 produce the best occlusal images when a 60 mm f/2.8 Macro lens is used. Better images are obtained with ring LED than with ring flash. Furthermore, ISO 3200 is required for low-magnification photography in natural light. Finally, intraoral digital images should be captured under low magnification, because tilted or deflected images can be adjusted by using imaging software.

AB - Background and objective: Recently, there have been produced several kinds of camera systems, lighting devices and image processing programs. The intraoral photographs are periodically required in pediatric dentistry, since the oral environment of children changes rapidly and dramatically because of disease, growth, and tooth eruption. However, the suitable settings for intraoral digital imaging have not yet been reported. In this study, single-lens reflex and mirrorless cameras were used with a ring flash, ring light emitting diode (LED), or standard fluorescent lamp to determine the optimal exposure parameters for occlusal photography. Materials and methods: Fifty-six dentists evaluated images of a discolored nonvital central incisor and first molar with recurrent caries and stained fissures clipped from a low-magnification photograph of the adult maxillary occlusal surface reflected in a mirror by using various F-numbers (representing aperture), shutter speeds, and International Organization for Standardization (ISO) numbers (representing light sensitivity). Results: The results showed that F-numbers between 5.6 and 10, shutter speeds faster than 1/30s, and ISO 800 produce the best occlusal images when a 60 mm f/2.8 Macro lens is used. Better images are obtained with ring LED than with ring flash. Furthermore, ISO 3200 is required for low-magnification photography in natural light. Finally, intraoral digital images should be captured under low magnification, because tilted or deflected images can be adjusted by using imaging software.

UR - http://www.scopus.com/inward/record.url?scp=84938484857&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84938484857&partnerID=8YFLogxK

U2 - 10.1016/j.pdj.2014.04.002

DO - 10.1016/j.pdj.2014.04.002

M3 - Article

AN - SCOPUS:84938484857

VL - 24

SP - 89

EP - 96

JO - Pediatric Dental Journal

JF - Pediatric Dental Journal

SN - 0917-2394

IS - 2

ER -