Evaluation of thermal comfort in a test room equipped with a photovoltaic assisted thermo-electric air duct cooling system

Kashif Irshad, Khairul Habib, M. W. Kareem, Firdaus Basrawi, Bidyut Baran Saha

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

This study investigates the comfort performance of a test room equipped with the south-facing photovoltaic wall (PV-W) and north-facing thermo-electric air duct (TE-AD) system for the tropical climate. Both subjective and objective measurements were used to analyze the TE-AD system cooling performance when operated at variable input current supply (2–7 A) from a PV system. Indoor radiant and air temperatures, relative humidity, and air velocity were measured based on ISO 7730 for objective measurement. For subjective measurement, forty respondents were required to fill up the questionnaire that developed based on UNI EN ISO 10551 and UNI EN ISO 7730 guidelines in order to access their thermal comfort opinion. The results show that the thermal response of respondents associated with indoor situation of the test room have changed from (+1) slightly warm to cool (−2) when the input current supply rises from 2 A to 6 A. The overall predicted mean vote, predicted percentage dissatisfied indices, and acceptability vote shows that more than 90% of the respondents were thermally satisfied. Integration of the PV-W system with the TE-AD system increases the thermal comfort and reduces the thermal load of the test room with other benefits includes less fuel and energy consumption, high reliability, and less maintenance operation.

Original languageEnglish
Pages (from-to)26956-26972
Number of pages17
JournalInternational Journal of Hydrogen Energy
Volume42
Issue number43
DOIs
Publication statusPublished - Oct 26 2017

Fingerprint

air ducts
thermal comfort
Thermal comfort
cooling systems
Cooling systems
Ducts
rooms
evaluation
Air
fuel consumption
comfort
air
energy consumption
acceptability
maintenance
climate
humidity
Thermal load
Fuel consumption
Atmospheric humidity

All Science Journal Classification (ASJC) codes

  • Renewable Energy, Sustainability and the Environment
  • Fuel Technology
  • Condensed Matter Physics
  • Energy Engineering and Power Technology

Cite this

Evaluation of thermal comfort in a test room equipped with a photovoltaic assisted thermo-electric air duct cooling system. / Irshad, Kashif; Habib, Khairul; Kareem, M. W.; Basrawi, Firdaus; Saha, Bidyut Baran.

In: International Journal of Hydrogen Energy, Vol. 42, No. 43, 26.10.2017, p. 26956-26972.

Research output: Contribution to journalArticle

@article{83c9bee7cc3e45f388735b80e3a571a9,
title = "Evaluation of thermal comfort in a test room equipped with a photovoltaic assisted thermo-electric air duct cooling system",
abstract = "This study investigates the comfort performance of a test room equipped with the south-facing photovoltaic wall (PV-W) and north-facing thermo-electric air duct (TE-AD) system for the tropical climate. Both subjective and objective measurements were used to analyze the TE-AD system cooling performance when operated at variable input current supply (2–7 A) from a PV system. Indoor radiant and air temperatures, relative humidity, and air velocity were measured based on ISO 7730 for objective measurement. For subjective measurement, forty respondents were required to fill up the questionnaire that developed based on UNI EN ISO 10551 and UNI EN ISO 7730 guidelines in order to access their thermal comfort opinion. The results show that the thermal response of respondents associated with indoor situation of the test room have changed from (+1) slightly warm to cool (−2) when the input current supply rises from 2 A to 6 A. The overall predicted mean vote, predicted percentage dissatisfied indices, and acceptability vote shows that more than 90{\%} of the respondents were thermally satisfied. Integration of the PV-W system with the TE-AD system increases the thermal comfort and reduces the thermal load of the test room with other benefits includes less fuel and energy consumption, high reliability, and less maintenance operation.",
author = "Kashif Irshad and Khairul Habib and Kareem, {M. W.} and Firdaus Basrawi and Saha, {Bidyut Baran}",
year = "2017",
month = "10",
day = "26",
doi = "10.1016/j.ijhydene.2017.05.247",
language = "English",
volume = "42",
pages = "26956--26972",
journal = "International Journal of Hydrogen Energy",
issn = "0360-3199",
publisher = "Elsevier Limited",
number = "43",

}

TY - JOUR

T1 - Evaluation of thermal comfort in a test room equipped with a photovoltaic assisted thermo-electric air duct cooling system

AU - Irshad, Kashif

AU - Habib, Khairul

AU - Kareem, M. W.

AU - Basrawi, Firdaus

AU - Saha, Bidyut Baran

PY - 2017/10/26

Y1 - 2017/10/26

N2 - This study investigates the comfort performance of a test room equipped with the south-facing photovoltaic wall (PV-W) and north-facing thermo-electric air duct (TE-AD) system for the tropical climate. Both subjective and objective measurements were used to analyze the TE-AD system cooling performance when operated at variable input current supply (2–7 A) from a PV system. Indoor radiant and air temperatures, relative humidity, and air velocity were measured based on ISO 7730 for objective measurement. For subjective measurement, forty respondents were required to fill up the questionnaire that developed based on UNI EN ISO 10551 and UNI EN ISO 7730 guidelines in order to access their thermal comfort opinion. The results show that the thermal response of respondents associated with indoor situation of the test room have changed from (+1) slightly warm to cool (−2) when the input current supply rises from 2 A to 6 A. The overall predicted mean vote, predicted percentage dissatisfied indices, and acceptability vote shows that more than 90% of the respondents were thermally satisfied. Integration of the PV-W system with the TE-AD system increases the thermal comfort and reduces the thermal load of the test room with other benefits includes less fuel and energy consumption, high reliability, and less maintenance operation.

AB - This study investigates the comfort performance of a test room equipped with the south-facing photovoltaic wall (PV-W) and north-facing thermo-electric air duct (TE-AD) system for the tropical climate. Both subjective and objective measurements were used to analyze the TE-AD system cooling performance when operated at variable input current supply (2–7 A) from a PV system. Indoor radiant and air temperatures, relative humidity, and air velocity were measured based on ISO 7730 for objective measurement. For subjective measurement, forty respondents were required to fill up the questionnaire that developed based on UNI EN ISO 10551 and UNI EN ISO 7730 guidelines in order to access their thermal comfort opinion. The results show that the thermal response of respondents associated with indoor situation of the test room have changed from (+1) slightly warm to cool (−2) when the input current supply rises from 2 A to 6 A. The overall predicted mean vote, predicted percentage dissatisfied indices, and acceptability vote shows that more than 90% of the respondents were thermally satisfied. Integration of the PV-W system with the TE-AD system increases the thermal comfort and reduces the thermal load of the test room with other benefits includes less fuel and energy consumption, high reliability, and less maintenance operation.

UR - http://www.scopus.com/inward/record.url?scp=85028363102&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028363102&partnerID=8YFLogxK

U2 - 10.1016/j.ijhydene.2017.05.247

DO - 10.1016/j.ijhydene.2017.05.247

M3 - Article

VL - 42

SP - 26956

EP - 26972

JO - International Journal of Hydrogen Energy

JF - International Journal of Hydrogen Energy

SN - 0360-3199

IS - 43

ER -