TY - JOUR
T1 - Experimental ablation study using a new long linear probe in isolated porcine hearts
AU - Shimoike, Eimei
AU - Ueda, Norihiro
AU - Maruyama, Toru
AU - Kaji, Yoshikazu
AU - Kanaya, Shozo
AU - Fujino, Takehiko
AU - Niho, Yoshiyuki
N1 - Copyright:
Copyright 2007 Elsevier B.V., All rights reserved.
PY - 1999/3
Y1 - 1999/3
N2 - We studied a new technique for creating long linear lesions in hearts using a custom-made linear probe. Radiofrequency (RF) energy applications using a 25-mm long stainless steel linear probe and a corresponding 500-kHz energy generator were tested, creating 90 lesions in isolated porcine hearts. The RF current was applied between the linear probe and a large patch electrode attached to the back of the specimen. Three parameters, comprising the power of the delivered energy, the pressure of contact between the probe and the specimen, and the duration of energy delivery were changed independently and the size of the resulting lesions was measured. All 90 lesions were transmural, well demarcated and created by a single stationary RF application. Lesion length and width increased with: 1) increasing power, when the other two parameters were maintained at constant levels, 2) increasing contact pressure, when the other two parameters were maintained at constant levels, and 3) increasing duration of energy delivery when the other two paramaters were maintained at constant levels. The maximum width of the lesions was 3.7 mm. No overheating of any of the specimens was observed. In conclusion, the new original long linear probe used in this study was effective for creating transmural linear lesions, presenting the possibility of a worthwhile contribution to the maze surgical procedure applied to atrial fibrillation.
AB - We studied a new technique for creating long linear lesions in hearts using a custom-made linear probe. Radiofrequency (RF) energy applications using a 25-mm long stainless steel linear probe and a corresponding 500-kHz energy generator were tested, creating 90 lesions in isolated porcine hearts. The RF current was applied between the linear probe and a large patch electrode attached to the back of the specimen. Three parameters, comprising the power of the delivered energy, the pressure of contact between the probe and the specimen, and the duration of energy delivery were changed independently and the size of the resulting lesions was measured. All 90 lesions were transmural, well demarcated and created by a single stationary RF application. Lesion length and width increased with: 1) increasing power, when the other two parameters were maintained at constant levels, 2) increasing contact pressure, when the other two parameters were maintained at constant levels, and 3) increasing duration of energy delivery when the other two paramaters were maintained at constant levels. The maximum width of the lesions was 3.7 mm. No overheating of any of the specimens was observed. In conclusion, the new original long linear probe used in this study was effective for creating transmural linear lesions, presenting the possibility of a worthwhile contribution to the maze surgical procedure applied to atrial fibrillation.
UR - http://www.scopus.com/inward/record.url?scp=0032895495&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032895495&partnerID=8YFLogxK
U2 - 10.1536/jhj.40.189
DO - 10.1536/jhj.40.189
M3 - Article
C2 - 10420880
AN - SCOPUS:0032895495
VL - 40
SP - 189
EP - 197
JO - International Heart Journal
JF - International Heart Journal
SN - 1349-2365
IS - 2
ER -