TY - JOUR
T1 - Experimental and CFD simulation of heat efficiency improvement ingeothermal spas
AU - Jalilinasrabady, Saeid
AU - Palsson, Halldor
AU - Saevarsdottir, Gudrun
AU - Itoi, Ryuichi
AU - Valdimarsson, Pall
N1 - Funding Information:
First author would like to express his gratitude to UNU-GTP in Iceland for his MSc fellowship. Contribution of Orkusjóður Orkustofnunar, Reykjavik energy and NORM-X HF Company and technical support from Mr. Vilhjálmur Sigurjónsson from the University of Iceland in the project, is gratefully appreciated. The first author gratefully acknowledges the support provided by Japan Society for the Promotion of Science ( JSPS ). The authors are grateful to the valuable comments from the reviewers that led to improve the quality of this paper.
PY - 2013/7/1
Y1 - 2013/7/1
N2 - Hot spas and jacuzzis are popular in Iceland due to the abundance of reasonably prized geothermal heat available. However the water from the DH (district heating) system is too warm to be admitted directly into the spa. For safety reasons the water is mixed with cold water, from 75. °C down to 50. °C, which leads to wasting a large quantity of heat. Therefore a design was suggested that enables the feeding of geothermal water directly into the pot, omitting the step of mixing it with cold water. The idea is to employ an open heat exchanger that transfers much heat from the geothermal water to the bulk water in the spa, before letting it mix with the spa water. A case study was done for one particular spa. Heat load was calculated and measured when the spa was in use, and when it was unused. A design is suggested employing a circular double-plate which is to be placed at bottom of pot. This unit will function as an open heat exchanger feeding DH water into the pot. Free convection takes place at the up side of the upper plate and forced convection below the upper plate. Heat-transfer coefficient for both was calculated. Temperature field in the pool before and after implementation of the open heat exchanger was measured at different points using thermocouples. The measured temperatures were compared to thermal and fluid-dynamic simulation of the temperature and flow fields obtaining good accordance. Results are reasonable and promising for a good design that may considerably reduce the energy expenses for a continuously heated geothermal spa. More detailed measurements were made on the upper plate of the heat exchanger and detailed simulation of the heat exchanger itself was then used to obtain a value for the heat-transfer coefficient for the upper plate to the surrounding water. This information was used to make an improved design for the open plate heat exchanger, stating that a diameter of 63. cm and a thickness of 1.5. cm were suggested as final design. Due to economy consideration the recovery time of the implementing of suggested heat exchanger is estimated to 8 months in studied case.
AB - Hot spas and jacuzzis are popular in Iceland due to the abundance of reasonably prized geothermal heat available. However the water from the DH (district heating) system is too warm to be admitted directly into the spa. For safety reasons the water is mixed with cold water, from 75. °C down to 50. °C, which leads to wasting a large quantity of heat. Therefore a design was suggested that enables the feeding of geothermal water directly into the pot, omitting the step of mixing it with cold water. The idea is to employ an open heat exchanger that transfers much heat from the geothermal water to the bulk water in the spa, before letting it mix with the spa water. A case study was done for one particular spa. Heat load was calculated and measured when the spa was in use, and when it was unused. A design is suggested employing a circular double-plate which is to be placed at bottom of pot. This unit will function as an open heat exchanger feeding DH water into the pot. Free convection takes place at the up side of the upper plate and forced convection below the upper plate. Heat-transfer coefficient for both was calculated. Temperature field in the pool before and after implementation of the open heat exchanger was measured at different points using thermocouples. The measured temperatures were compared to thermal and fluid-dynamic simulation of the temperature and flow fields obtaining good accordance. Results are reasonable and promising for a good design that may considerably reduce the energy expenses for a continuously heated geothermal spa. More detailed measurements were made on the upper plate of the heat exchanger and detailed simulation of the heat exchanger itself was then used to obtain a value for the heat-transfer coefficient for the upper plate to the surrounding water. This information was used to make an improved design for the open plate heat exchanger, stating that a diameter of 63. cm and a thickness of 1.5. cm were suggested as final design. Due to economy consideration the recovery time of the implementing of suggested heat exchanger is estimated to 8 months in studied case.
UR - http://www.scopus.com/inward/record.url?scp=84878976731&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84878976731&partnerID=8YFLogxK
U2 - 10.1016/j.energy.2013.04.057
DO - 10.1016/j.energy.2013.04.057
M3 - Article
AN - SCOPUS:84878976731
SN - 0360-5442
VL - 56
SP - 124
EP - 134
JO - Energy
JF - Energy
ER -